J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edwards, G. D.
Right arrow Articles by Jones, S. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edwards, G. D.
Right arrow Articles by Jones, S. P.

British Journal of Orthodontics, Vol 22, 145-153, Copyright © 1995 by British Orthodontic Society


ARTICLES

The ex vivo effect of ligation technique on the static frictional resistance of stainless steel brackets and archwires

GD Edwards, EH Davies and SP Jones
Department of Orthodontics, Institute of Dental Surgery, London, UK.

This ex vivo investigation compared the effect of various orthodontic ligation techniques on the static frictional resistance of stainless steel brackets and archwires under both dry and wet conditions. The techniques studied were: elastomeric modules tied conventionally and in a 'figure of 8' pattern, stainless steel ligatures, and Teflon-coated ligatures. The first part of the investigation involved the construction of calibration curves for each of the materials, so an estimate of the normal force exerted by the ligatures could be ascertained. Secondly, a pair of ligature locking pliers were modified so that ligatures could be placed with a standardized force. Finally, the four methods of ligation were directly compared on a specially constructed testing apparatus. Results revealed that elastomeric modules tied in a 'figure of 8' pattern produced significantly more friction than any other method tested, under both dry and wet conditions. No significant differences in frictional resistance were found between conventionally tied elastomeric modules and stainless steel ligatures. Teflon-coated ligatures, however, were associated with the lowest frictional forces. The results of the calibration tests indicated that the normal forces exerted by all four methods of ligation may be higher than previously estimated.


This article has been cited by other articles:


Home page
J. Orthod.Home page
Commentaries on scientific papers published in this edition
J. Orthod., June 1, 2008; 35(2): 110 - 111.
[Full Text] [PDF]


Home page
J. Orthod.Home page
J. E. Haskova, G. Palmer, and S. P. Jones
An ex vivo laboratory study to determine the static frictional resistance of a variable ligation orthodontic bracket system
J. Orthod., June 1, 2008; 35(2): 112 - 118.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 British Orthodontic Society.