J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nattrass, C.
Right arrow Articles by Sherriff, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nattrass, C.
Right arrow Articles by Sherriff, M.

British Journal of Orthodontics, Vol 24, 127-131, Copyright © 1997 by British Orthodontic Society


ARTICLES

An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure

C Nattrass, AJ Ireland and M Sherriff
Department of Child Dental Health, Bristol Dental Hospital, U.K.

This in vitro investigation was designed to establish not only how clinicians apply forces for space closure when using the straight wire appliance and sliding mechanics, but also to quantify the initial force levels produced. A single typodont, with residual extraction space in each quadrant, was set up to simulate space closure using sliding mechanics. On two occasions, at least 2 months apart, 18 clinicians were asked to apply three force delivery systems to the typodont, in the manner in which they would apply it in a clinical situation. The three types of force delivery system investigated were elastomeric chain, an elastomeric module on a steel ligature, and a nickel-titanium closed coil spring. A choice of spaced or unspaced elastomeric chain produced by a single manufacturer was provided. The amount of stretch which was placed on each type of system was measured and, using an Instron Universal Testing Machine, the initial force which would be generated by each force delivery system was established. Clinicians were assessed to examine their consistency in the amount of stretch which each placed on the force delivery systems, their initial force application and their ability to apply equivalent forces with the different types of force delivery system. The clinicians were found to be consistent in their method of application of the force delivery systems and, therefore, their force application, as individuals, but there was a wide range of forces applied as a group. However, most clinicians applied very different forces when using different force delivery systems. When using the module on a ligature the greatest force was applied, whilst the nickel titanium coil springs provided the least force.


This article has been cited by other articles:


Home page
J. Orthod.Home page
B. S. Khambay, S. McHugh, and D. T. Millett
Magnitude and reproducibility of forces generated by clinicians during laceback placement
J. Orthod., December 1, 2006; 33(4): 270 - 275.
[Abstract] [Full Text] [PDF]


Home page
J. Orthod.Home page
C. Nightingale and S. P. Jones
A clinical investigation of force delivery systems for orthodontic space closure
J. Orthod., September 1, 2003; 30(3): 229 - 236.
[Abstract] [Full Text] [PDF]


Home page
J. Orthod.Home page
V. Dixon, M. J. F. Read, K. D. O'Brien, H. V. Worthington, and N. A. Mandall
A randomized clinical trial to compare three methods of orthodontic space closure
J. Orthod., March 1, 2002; 29(1): 31 - 36.
[Abstract] [Full Text] [PDF]


Home page
J. Orthod.Home page
A. Johal, S. Loh, and J. K. Heng
A Clinical Investigation into the Behaviour of Crimpable Archwire Hooks
J. Orthod., September 1, 2001; 28(3): 203 - 206.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 British Orthodontic Society.