J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lim, K. F.
Right arrow Articles by Foong, K. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lim, K. F.
Right arrow Articles by Foong, K. W.

British Journal of Orthodontics, Vol 24, 301-308, Copyright © 1997 by British Orthodontic Society


ARTICLES

Phosphor-stimulated computed cephalometry: reliability of landmark identification

KF Lim and KW Foong
Government Dental Clinic, Singapore.

The aim of this randomized, controlled, prospective study was to determine the reliability of computed lateral cephalometry (Fuji Medical Systems, Tokyo, Japan) in terms of landmark identification compared to conventional lateral cephalometry (CAWO, Schrobenhausen, Germany). To assess the reliability of landmark identification on lateral cephalographs, 20 computed images, taken at 30 per cent reduced radiation (70 kV, 15 mA, 0.35 s) were compared to 20 conventional images (70 kV, 15 mA, 0.5 s). The 40 lateral cephalographs were taken from 20 orthodontic patients at immediate post-treatment and 1 year after retention. The order and type of imaging was randomized. Five orthodontists identified eight skeletal, four dental and five soft tissue landmarks on each of the 40 films. The error of identification was analysed in the XY Cartesian co-ordinate following digitization. Skeletal landmarks exhibited characteristic dispersion with respect to the Cartesian co-ordinates. Root apices were more variable than crown tips. Soft tissue landmarks were more consistent in the X co-ordinate. Two-way ANOVA shows that there is no significant difference between the two imaging systems in both co-ordinates (P > 0.05). Moreover, the differences are generally small (< 0.5 mm), and are unlikely to be of clinical significance. Most of the variables attained statistical power of at least 0.8 in the X-co-ordinate while only the dental landmarks achieved statistical power of at least 0.78 in the Y-co-ordinate. Based on the results of the study: (1) computed lateral cephalographs can be taken at 30 per cent radiation reduction, compared to conventional lateral cephalograph; (2) each anatomical landmark exhibits its characteristic dispersion of error in both the Cartesian co-ordinates; (3) there is no trend between the two imaging systems, with equivocal result, and none of the landmarks attained statistical significance when both raters and imaging systems are considered as factorial variables; (4) the random error of raters in landmark identification after replicate tracing was highlighted and needs to be taken into consideration in all studies involving landmark identification.


This article has been cited by other articles:


Home page
Eur J OrthodHome page
D. P. Dvortsin, A. Sandham, G. J. Pruim, and P. U. Dijkstra
A comparison of the reproducibility of manual tracing and on-screen digitization for cephalometric profile variables
Eur J Orthod, August 21, 2008; (2008) cjn041v1.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
Y-J Chen, S-K Chen, H-W Huang, C-C Yao, and H-F Chang
Reliability of landmark identification in cephalometric radiography acquired by a storage phosphor imaging system
Dentomaxillofac. Radiol., September 1, 2004; 33(5): 301 - 306.
[Abstract] [Full Text] [PDF]


Home page
J. Orthod.Home page
J. Brennan
An introduction to digital radiography in dentistry
J. Orthod., March 1, 2002; 29(1): 66 - 69.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 British Orthodontic Society.