J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coley-Smith, A.
Right arrow Articles by Rock, W.P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coley-Smith, A.
Right arrow Articles by Rock, W.P.
British Journal of Orthodontics, Vol. 26, No. 2, 135-139, June 1999
© 1999 British Orthodontic Society

Distortion of Metallic Orthodontic Brackets After Clinical Use and Debond by Two Methods

A. Coley-Smith, B.D.S., M.DENT., S.C., F.D.S., M.ORTH., R.C.S. and W.P. Rock, B.D.S., D.D.S., F.D.S., D.ORTH., R.C.S.

School of Dentistry, St Chad's Queensway, Birmingham. B4 6NN, UK

The objective of this paper was to compare distortion of the wings and bases of metallic orthodontic brackets following clinical use and after debond by either of two methods, and took the form of a prospective random control trial. Five-hundred-and-seven brackets were debonded using either bracket removing pliers or a lift off debonding instrument (LODI). By a system of random allocation contralateral opposing quadrants were debonded with a 0.019 x 0.0025-inch archwire either in place or removed. After debond brackets were tested for slot closure by the fit of rectangular test wires from 0.016 x 0.022 to 0.021 x 0.025 inch size. The LODI produced few slot closures sufficient to affect the fit of all but the largest test wire. Bracket removing pliers used after removal of the archwire produced significantly greater numbers of distorted brackets in response to testing with all but the largest wire. With the 0.021 x 0.025 inch wire in place the presence or absence of the archwire at the time of debond made no difference to the number of slot closures. Ten per cent of the brackets debonded using bracket removing pliers had distorted bases, no base damage was produced by the LODI. The use of bracket removing pliers at debond caused significantly more slot closures than use of the LODI. When bracket removing pliers are used the archwire should be left in place at the time of debond since this reduces the number of distortions.

Key words: Brackets, Recycling

Refereed Paper







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 British Orthodontic Society.