J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mori, Y.
Right arrow Articles by Sakuda, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mori, Y.
Right arrow Articles by Sakuda, M.
Journal of Orthodontics, Vol. 28, No. 2, 143-149, June 2001
© 2001 British Orthodontic Society


Scientific Section

An Accurate Three-dimensional Cephalometric System: a Solution for the Correction of Cephalic Malpositioning

Yoshihide Mori, D.D.S., PH.D., Takahiro Miyajima, D.D.S., PH.D., Katsuhiro Minami, D.D.S., PH.D. and Masayoshi Sakuda, D.D.S., PH.D.

2nd Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Osaka University, 1–8, Yamadaoka, Suita, Osaka 565-0871, Japan

Abstract

In recent years, methods have been developed that calculate three-dimensional (3D) co-ordinates of orthodontic landmarks from lateral and frontal cephalograms. However, precise measurement has been impossible with these methods because, although they corrected the magnification of the image, they did not correct 3D cephalic malpositioning that occurs during the measurement of human subjects. In this study, we developed a 3D cephalometric system that corrected not only for magnification of the image, but also 3D cephalic malpositioning during cephalogram exposure.

Magnification of the image was corrected for first. Cephalic revolution was then sequentially corrected and divided into elements of x-, y-, and z-axes. The origin was parallelly translated to the mid-point of bilateral porion. In order to examine the accuracy of this system, seven human dry skulls were measured.

The accuracy unaffected by the cephalic revolution in any direction and standard errors was within 0·8 mm in any orthodontic landmarks. It was suggested that this measurement system would have sufficient accuracy for clinical application.

The results indicated that precise cephalometric measurement was possible with this system and it was suggested that its clinical application would be possible.

Key words: Three-dimensional analysis, Cephalometry, Stereograms, Mathematical Correction.