J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.
Journal of Orthodontics, Vol. 28, No. 3, 237-244, September 2001
© 2001 British Orthodontic Society


Scientific Section

An Ex Vivo Investigation into the Use of a Plasma Arc Lamp When Using a Visible Light-cured Composite and a Resin-modified Glass Poly(Alkenoate) Cement in Orthodontic Bonding

A. P. Pettemerides1, A. J. Ireland2 and M. Sherriff, Bsc3

1 Edgar Buildings Dental Practice, Edgar Buildings, Bath BA1 2EE, UK
2 Department of Orthodontics, Royal United Hospital, Bath BA1 3NG, UK
3 Department of Dental Biomaterials Science, Floor 17, Guy's Tower, London SE1 9KT, UK

A. J. Ireland

Abstract

Objective: To determine the usefulness of the plasma arc lamp in orthodontic bonding when used with both a light curable diacrylate and a resin modified glass poly(alkenoate) cement.

Design: Ex-vivo study.

Method: 160 second premolar teeth were divided into 2 groups. 80 teeth had steel brackets bonded using Transbond XT and 80 were bonded using Fuji Ortho LC. One of four light curing regimes were used, with 20 specimens in each group: (i) 20 seconds curing with a halogen lamp; (ii) 1 second; (iii) 2 seconds or; (iv) 3 seconds with the plasma lamp.

Outcomes: Shear bond tested to failure and the force to debond (N) and locus of bond failure recorded in each case.

Results: Force to debond increases in the case of both bonding materials as the curing time with the plasma lamp increases. The force to debond with 1 and 2 seconds with the plasma lamp was significantly lower in each case. In all instances the force to debond was lower in the case of the resin modified glass poly(alkenoate) cement specimens. Locus of bond failure was unaffected by the method and length of light curing and was generally mixed mode.

Conclusions: Use of the plasma arc lamp in orthodontic bonding could result in significant time saving.