J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lam, T. V.
Right arrow Articles by Podlich, H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lam, T. V.
Right arrow Articles by Podlich, H. M.
Journal of Orthodontics, Vol. 29, No. 1, 37-43, March 2002
© 2002 British Orthodontic Society


Scientific Section

Strength decay of orthodontic elastomeric ligatures

T. V. Lam, T. J. Freer, P. J. Brockhurst and H. M. Podlich

University of Queensland, Australia

Address for correspondence:
Professor T. J. Freer, School of Dentistry, University of Queensland, Turbot Street, Brisbane, Queensland 4000, Australia. E-mail:
t.freer{at}mailbox.uq.edu.au

Abstract

Aim To evaluate, over a 12-week period, the tensile strength (TS) and extension to TS of elastomeric ligatures (both clear and coloured) obtained from two companies.

Setting Ex vivo study.

Method Seven replicates of five ligatures from two orthodontic companies were tested using an ex vivo assembly which simulated a clinical situation.

Results The ligatures tested had a similar TS decay pattern, with the TS gradually decreasing over the duration of the study. The Unitek ligatures exhibited a greater TS than their respective Ormco ligatures. Generally, all of the ligatures tested experienced an increase in the extension to TS over time. The pre-stretching procedure used in this study did not produce any long-term detrimental effects on the TS and extension to TS of the ligatures tested.

Conclusions The results of this study confirm there are differences in TS, and extension to TS between clear and coloured elastomeric ligatures, and that some significant differences also exist between different brands of elastomeric ligatures.

Key words: Elastomerics, ligatures, pre–stretching, tensile, strength