J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nightingale, C.
Right arrow Articles by Jones, S. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nightingale, C.
Right arrow Articles by Jones, S. P.
Journal of Orthodontics, Vol. 30, No. 3, 229-236, September 2003
© 2003 British Orthodontic Society


Scientific Section

A clinical investigation of force delivery systems for orthodontic space closure

C. Nightingale and S. P. Jones

Eastman Dental Hospital, London, UK

Claire Nightingale, 74 Antrim Mansions, Antrim Road, London NW3 4XL, UK. E-mail: claire{at}nightingales.org.uk

Objective: To investigate the force retention, and rates of space closure achieved by elastomeric chain and nickel titanium coil springs.

Design: Randomized clinical trial.

Setting: Eastman Dental Hospital, London and Queen Mary’s University Hospital, Roehampton, 1998–2000.

Subjects, materials and methods: Twenty-two orthodontic patients, wearing the pre-adjusted edgewise appliance undergoing space closure in opposing quadrants, using sliding mechanics on 0.019 x 0.025-inch posted stainless steel archwires. Medium-spaced elastomeric chain [Durachain, OrthoCare (UK) Ltd., Bradford, UK] and 9-mm nickel titanium coil springs [OrthoCare (UK) Ltd.] were placed in opposing quadrants for 15 patients. Elastomeric chain only was used in a further seven patients. The initial forces on placement and residual forces at the subsequent visit were measured with a dial push–pull gauge [Orthocare (UK) Ltd]. Study models of eight patients were taken before and after space closure, from which measurements were made to establish mean space closure.

Main outcome measures: The forces were measured in grammes and space closure in millimetres.

Results: Fifty-nine per cent (31/53) of the elastomeric sample maintained at least 50 per cent of the initial force over a time period of 1–15 weeks. No sample lost all its force, and the mean loss was 47 per cent (range: 0–76 per cent). Nickel titanium coil springs lost force rapidly over 6 weeks, following that force levels plateaued. Forty-six per cent (12/26) maintained at least 50 per cent of their initial force over a time period of 1–22 weeks, and mean force loss was 48 per cent (range: 12–68 per cent). The rate of mean weekly space closure for elastomeric chain was 0.21 mm and for nickel titanium coil springs 0.26 mm. There was no relationship between the initial force applied and rate of space closure. None of the sample failed during the study period giving a 100 per cent response rate.

Conclusions: In clinical use, the force retention of elastomeric chain was better than previously concluded. High initial forces resulted in high force decay. Nickel titanium coil springs and elastomeric chain closed spaces at a similar rate.

Key words: Elastomeric chain, force decay, in vivo study, nickel titanium coil springs, space closure




This article has been cited by other articles:


Home page
J. Orthod.Home page
M. A. Hain, L. P. Longman, E. A. Field, and J. E. Harrison
Natural rubber latex allergy: implications for the orthodontist
J. Orthod., March 1, 2007; 34(1): 6 - 11.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 British Orthodontic Society.