J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 33, No. 4, 270-275, December 2006 doi:10.1179/146531205225021762
© 2006 British Orthodontic Society

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Khambay, B. S.
Right arrow Articles by Millett, D. T.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Khambay, B. S.
Right arrow Articles by Millett, D. T.

Scientific Section

Magnitude and reproducibility of forces generated by clinicians during laceback placement

B. S. Khambay and S. McHugh

Glasgow Dental Hospital and School, UK

D. T. Millett

University Dental School and Hospital, Cork, Ireland

Address for correspondence: Dr. B. S. Khambay, Unit of Orthodontics, Glasgow Dental School, 378 Sauchiehall Street, Glasgow, G2 3JZ, UK., Email: bkhambay{at}yahoo.com


   Abstract

Objective: To determine the magnitude and reproducibility of forces generated by clinicians during laceback placement using a force-measuring typodont.

Setting: An in vitro investigation.

Materials and methods: An in vitro typodont model was developed, which incorporated strain gauges attached to a personal computer to allow measurement of the force generated on application of lacebacks. Ten operators were instructed to place lacebacks five times, on two separate occasions (T1 and T2). Inter-operator and intra-operator forces produced at T1 and T2 were compared.

Main outcome measures: Forces generated by laceback placement.

Results: The forces generated by clinicians ranged from 0 to 11.1 N. There were significant differences in the mean forces generated by the different operators (P < 0.001), with differences between time points not being consistent across all operators (P < 0.001). Some operators were more consistent than others in the forces generated.

Conclusion: In vitro, there was a large inter-operator variation in the forces produced during laceback placement. With the in vitro model used in this study, few operators applied similar forces when placing lacebacks on two separate occasions.

Key words: Lacebacks, force magnitude, typodont







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 British Orthodontic Society.