Scientific Section |
Burnley General Hospital Burnley, Lancashire, UK
Department of General Practice and Primary Care, The University of Aberdeen, UK
Address for correspondence: Mr Philip Banks, Orthodontics Department, Burnley General Hospital, Casterton Avenue, Burnley, Lancashire BB10 2PQ, UK. Email: philbanks_burnly{at}yahoo.com
| Abstract |
|---|
Objective: To compare the clinical failure rates of bonded first molar tubes with those of cemented bands during fixed appliance therapy.
Design: Prospective randomized controlled clinical trial.
Setting: Two UK hospital orthodontic clinics, February 2001December 2004.
Participants: Hospital waiting list patients needing fixed appliances (n = 110).
Method: Patients were randomly allocated to two groups. Experimental group patients (n = 55) received single first molar tubes (n = 181) bonded with a no-mix chemically cured composite (Rely-A-Bond) after a 30-second etch. Control group patients (n = 55) were treated with bands (n = 186) cemented with Intact glass ionomer cement (GIC). First-time failures were recorded together with the time of failure. All patients were followed to the end or discontinuation of treatment.
Results: First-time failures: bands = 18.8%; bonds = 33.7 %. Bonded tubes were more likely to fail [RR 2.4; 95% CI (1.4, 4.1)] compared with bands. Experimental group patients also had more bracket failures (P = 0.009), when analysed at patient level.
Conclusion: First molar tubes bonded with Rely-A-Bond composite showed a significantly higher first-time failure rate than bands cemented with Intact GIC.
Key words: Molar bonds, molar bonded tubes, Rely-A-Bond, Intact, randomized controlled clinical trial, molar attachment failure rates