J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 35, No. 2, 112-118, June 2008 doi:10.1179/146531207225022527
© 2008 British Orthodontic Society

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Haskova, J. E.
Right arrow Articles by Jones, S. P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haskova, J. E.
Right arrow Articles by Jones, S. P.

Scientific Section

An ex vivo laboratory study to determine the static frictional resistance of a variable ligation orthodontic bracket system

Joanna E. Haskova, Graham Palmer and Steven P. Jones

UCL Eastman Dental Institute, London, UK

Address for correspondence: Mr Steven P. Jones, Orthodontic Consultant, UCL Eastman Dental Institute, 256 Gray’s Inn Road, London, WC1X 8LD, UK. Email: S.Jones{at}eastman.ucl.ac.uk


   Abstract

Objective: To determine the effects of static frictional resistance on varying the ligation technique in a Delta Force bracket system (Ortho Organizers Ltd, Hampton, UK) and using increasing degrees of bracket/archwire angulation to simulate binding.

Design: An ex vivo laboratory investigation using the Instron Universal Testing Machine (Instron Ltd, High Wycombe, UK) to generate sliding forces on an archwire through the Delta Force bracket. The system was lubricated with Saliva Orthana artificial saliva (Nycomed Ltd, Buckinghamshire, UK).

Setting: Biomaterials Laboratory, Eastman Dental Institute, London, UK.

Materials and method: Ninety Delta Force brackets were tested against 0.018-inch stainless steel wire. Three modes of ligation were tested with three different angulations: 0, 5 and 10° to simulate increasing levels of binding.

Results: The average static frictional resistance went from 0.20 N, at 0° angulation and minimum ligation, to 2.37 N with 10° angulation and maximum ligation. Results revealed that the ligation pattern was found to be highly statistically significant (P<0.001) in influencing frictional force. The binding angle showed a trend of increasing frictional force with increasing bracket/archwire angulation. Repeatability testing showed no evidence of bias (P=0.171).

Conclusions: These results suggest that the Delta Force variable ligation system does in fact enable friction to be varied, which may have implications in clinical application.

Key words: Variable ligation brackets, static frictional resistance, Delta Force brackets







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 British Orthodontic Society.