Journal of Orthodontics, Vol. 28, No. 1, 68, March 2001
© 2001 British Orthodontic Society


Letter to the Editor

Lucy Macey-Dare, BDS MSc FDS MOrth RCS

Dear Sir

A Case Report: dislodgement of an orthodontic bracket into a sagittal split site

During orthognathic surgery there is always the potential for instrumentation to cause bracket dislodgement. However, to my knowledge, there have been no previously recorded cases of a fixed appliance component being retained at the actual surgical site. Retention of such a foreign body not only poses a potential health risk, but also has medico-legal implications (Machen, 1989Go) and this is the subject of the current case report.

This letter reports a 19-year-old Caucasian woman who had been undergoing upper and lower fixed orthodontic appliance therapy for 15 months in preparation for a bilateral sagittal split osteotomy to advance her mandible to correct her severe Skeletal II discrepancy. She had all four first premolars and her lower wisdom teeth extracted some 7 months earlier, and at the start of treatment was fitted with stainless steel brackets on the remainder of her permanent dentition, including her first and second molars.

Prior to surgery full thickness archwires were placed in both arches, and all the components were checked and found to be secure.

Surgery was carried out under naso-tracheal intubation and consisted of mobilizing the mandible into an inter-positional wafer and then stabilizing it with 30-gauge stainless steel wire passing between surgical hooks on the archwire, and onto integral hooks on the first and second molar brackets. Following plating of her mandible, the temporary intermaxillary fixation was then released and the surgical site closed.

Two days later, however, prior to discharge, a posteroanterior radiograph revealed a dislodged orthodontic bracket lying in the superior aspect of the left sagittal split osteotomy site (Figure 1Go) and intra-oral examination confirmed absence of the lower left second molar bracket. The patient was informed, placed on a 5-day course of amoxycillin and a second general anaesthetic arranged for retrieval of the bracket, 28 days after the original surgery.



View larger version (92K):
[in this window]
[in a new window]
 
Fig. 1   Posteroanterior view of the jaws showing dislodgement of a second molar orthodontic bracket lying in the left osteotomy site.

 
During this procedure, careful dissection of the soft tissues overlying the left osteotomy site revealed the position of the second molar bracket, which was subsequently retrieved.

The patient made an uneventful recovery and went on to continue her fixed appliance therapy for a further 9 months.

Although dislodgement of an orthodontic bracket into the surgical site is a rare complication to avoid such a similar case I would suggest:

  1.  placing bands rather than brackets on the terminal molars;
  2.  checking all the fixed appliance components during the procedure and especially before the surgical site is closed.

Difficulties can arise, however, where ceramic brackets have been used as not only do they fracture more readily (Flores et al., 1990Go), but their transparency and radiolucency make them more difficult to locate at operation, and also during recovery when the cough reflex is suppressed. It has therefore been suggested (Proffit and White, 1991Go) that, in such cases, either stainless steel brackets or ceramic brackets with integral metal slots are used.

Notes

Queen Alexandra Hospital, Portsmouth PO6 3LY, UK

References

Flores D. A., Caruso J. M., Scott G. E. and Jeiroudi M. T. (1990) The fracture strength of ceramic brackets: a comparative study, Angle Orthodontist, 60, 269–276.[Medline]

Machen, D. E. (1989) Legal aspects of orthodontic practice: risk management concepts, American Journal of Orthodontics and Dentofacial Orthopedics, 95, 267–268.[Medline]

Proffit W. R. and White R. P. (1991) In: Surgical Orthodontic Treatment, Mosby Year Book Inc., St Louis, pp. 204–205.





This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Macey-Dare, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Macey-Dare, L.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS