|
|
||||||||
Scientific Section |
Department of Oral and Maxillofacial Surgery, Eastman Dental Institute for Oral Health Care, Sciences, University College London, UK
Dr M. Anwar Bamber, Department of Oral and Maxillofacial Surgery, Eastman Dental and University College London Hospitals, 256 Grays Inn Road, London WC1X 8LD, UK. Tel/Fax: 0171 9151226. E-mail: A.Bamber{at}eastman.ucl.ac.uk.
Abstract
In order to create an evidence-based orthognathic surgery planning protocol, an investigation of two popular model surgery techniques, the Lockwood keyspacer and the Eastman anatomically-orientated system was carried. This determined (a) the accuracy of positioning of the maxillary cast according to the prescribed treatment plan and (b) the relocation of the maxilla after a simulated Le Fort I down fracture osteotomy using the intermediate wafer as a guide. Fifteen patientsfive Class II division 1, five Class II division 2, and five Class IIIwere included in the study. All the measurements were taken with Erickson's vertically mounted electronic calliper and variations from the treatment plan were analysed.
The mean model surgery positioning errors ± SD (mm) were: (i) vertical planeLockwood 08 ± 16 and Eastman 000 ± 10 (P = 00001); (ii) anteroposterior planeLockwood 12 ± 18 and Eastman 01 ± 14 (P = 005); and (iii) transverse planeLockwood 09 ± 09 and Eastman 10 ± 09 (P = 034).
After the simulated osteotomy, the mean errors ± SD were: (i) vertical planeLockwood 05 ± 15 and Eastman 03 ± 11 (P = 0001); (ii) in anteroposterior planeLockwood 08 ± 20 and Eastman 07 ± 10 (P = 089); and (iii) transverse planeLockwood 08 ± 06 and Eastman 07 ± 05 (P = 083).
The Eastman technique was relatively better especially in the vertical plane. The variations from the treatment plan were on the whole anatomically small, but in some cases could be clinically significant.
Key words: Model surgery errors, Orthognathic work-up, Simulated osteotomy errors.
Introduction
Surgery of the facial skeleton involves complex three dimensional movements based on a series of non-surgical and surgical procedures. Bimaxillary osteotomies, which change the occlusal level to improve function and enhance physical appearance, require to be planned preoperatively with the help of model surgery.
The early pioneers (Hullihen, 1849
; Angle, 1903
; Blair, 1907
) relied heavily upon their clinical and surgical experience. Kostecka (1931) used unarticulated models to evaluate the pre- and post-operative occlusion for his ostectomy of the ascending rami. Subsequently, segments of the sectioned models were held together with wax and a German silver alloy splint was fabricated for fixation (Wassmund, 1935
).
Custom made full scale plastic facsimiles of the mandibular rami to give an accurate three-dimensional (3D) representation of the ramus, condyles and intercondylar distance have also been suggested by Ellis et al. (1984), and Krenkle and Lixl (1991). It is claimed that this avoids condylemeniscusfossa problems at the time of screw fixation during the operation. However, replication of the cortical plates cannot be predicted with accuracy especially if the sagittal split of the ramus does not go as planned. Heggie (1987) challenged the accuracy of model surgery and suggested the use of a calibrator (modified Vernier calliper) to assess the maxillary position during surgery. The calibrator registers the distance between the nasion, an arbitrary point on the nose and the midline incisor tip. Contrary to established practice, Lindorf and Steinhauser (1978), and Cottrell and Wolford (1994) suggested altering the sequence of bimaxillary model surgery planning and operative procedure. They proposed that in cases of a large mandibular advancement, if the thin-walled maxilla is repositioned first, then a maxillary shift may occur whilst the maxillomandibular fixation is applied. They therefore performed the mandibular surgery first using cephalometric tracings to predict the postoperative position. The mandible is then stabilized with rigid fixation before placing the maxilla into an ideal occlusion.
However, the use of an anatomical articulator with a facebow transfer for bimaxillary osteotomies is essential to achieve accuracy of the maxillary position in space and its relationship to the optimum functional centric occlusion (Hohl, 1978
; Bamber and Harris, 1995
).
The diagnostic information gained from preoperative clinical and radiographic assessment and model analysis is integrated to establish a treatment plan. This treatment plan is expressed in the model surgery, and the simulated post-operative model relationships are used to fabricate the intermediate and final occlusal wafers. These wafers are an essential means of transferring the treatment plan into an accurate surgical procedure. However, there is uncertainty concerning the accuracy of model surgery and in particular the difference between the popular Lockwood keyspacer system (Lockwood, 1974
) and the Eastman anatomically-orientated technique (Anwar and Harris, 1990
). As small discrepancies can have a significant effect on outcome, it seemed essential to examine this stage of the orthognathic planning process to help create an evidence-based system.
The Lockwood keyspacer system and the Eastman anatomically-orientated model surgery technique are the most widely used techniques in this country. A review by telephone of 60 Oral and Maxillofacial Surgery departments revealed; 13 used the modified Lockwood method, six anatomically-orientated models, four used unidentified techniques, 10 did not use any model surgery, and the remainder (27) did not disclose their technique. Both techniques allow movement of the maxillary and mandibular casts in three spatial planes within the articulator, analogous to the surgical movement of the jaws within the facial skeleton. The Lockwood Keyspacer system incorporates thin plaster or rarely plastic keyspacers (Peretta and Caruso, 1983
) at the interface between the upper and lower models, and the articulator plaster mounting assembly. These plaster inserts are usually 7 mm thick and follow the shape of a dental model base. They are held in place with elastics, Esplits plastic locks or sometimes with magnets. Since Lockwood described the technique using casts mounted on a plane line hinge articulator, the technique has been enhanced by using a facebow registration and an anatomical articulator Figure 1a
).
|
We believe the key movement in clinical planning and surgery is the positioning of the maxilla. There is an undoubted error when this is determined by the intermediate wafer based on the rotation of the supine anaesthetized condyle axis. This error represents the difference between the conscious upright centric occlusion or centric relation and the supine anaesthetized centric relation, which is described elsewhere (Bamber et al., 1999
). This maxillary position error is largely masked or compensated for by the final wafer relating the osteotomized mandible to the maxilla once it has been fixed by bone plates. For this reason, the investigation was designed to validate the accuracy of two popular model surgery techniques in positioning the maxilla.
Aims of the Study
Aims of this investigation were to compare the Lockwood Keyspacer System and the Eastman anatomically-orientated model surgery technique for (a) the accuracy of the maxillary cast position according to the prescribed treatment plan and (b) the relocation of the maxilla after a simulated Le Fort I down fracture osteotomy using the intermediate wafer as a guide, in three skeletal groups.
Patients and Methods
Fifteen osteotomy patients (eight male and seven female; five Class II division 1, five Class II division 2, and five Class III, including one Class III anterior open bite, were included in this investigation. All the patients had bimaxillary osteotomies with a one piece Le Fort I procedure except one, who had a Le Fort I down fracture and an anterior segmental procedure with a midline split. The treatment plan was agreed by the surgeon and orthodontist.
Upper and lower impressions, a facebow registration, a facial midline recording, an occlusal record and clinical measurements, following a standard orthognathic protocol (Bamber, 1995
; Bamber et al 1996
, 1999
), were recorded for each patient. The impressions were cast in class two dental stone and the models triplicated.
One set of models was anatomically mounted and retained for the mock surgery (Figure 1c
). The remaining two sets were mounted for the Lockwood and the Eastman model surgery technique. Although the original Lockwood Keyspacer technique description does not use a facebow registration the Denar facebow and anatomical articulator (Denar Corporation, USA) were used for both techniques to ensure a common starting point. Baseline measurements of both mounted models were taken and the model surgery carried out according to the treatment plan. The models were transferred to the Erickson measuring apparatus and any variations in the maxillary position from the treatment plan were computed (see Figure 2
).
|
|
The Erickson's model surgery platform employs a screw base plate on the model block identical to the articulator so that the models can be mounted on it with a mounting screw and indexing pins in a reproducible manner (Ellis, 1990; Figure 3c
). This was used to measure changes in the three planes, its metric electronic calliper gives a digital display read out with an accuracy of 001 mm, (Great Lakes Orthodontic Products Ltd., Tonawanda, New York, USA).
The pre- and post-operative positions of the maxillary model were recorded in the vertical, anteroposterior, and transverse (mediolateral) planes, at the following reference points; VM, VB, VC, and VF described earlier (Figure1b
). These reference points provide seven measurements per case, and a potential total of 105 pre- and post-operative measurements, except with differential impaction or rotating movements where only VF and VM were used.
The actual movements achieved in three planes by each method, after the model and the simulated surgery, were calculated and compared with the patient's original treatment plan.
Results
Model surgery error
Descriptive statistics (mean ± SD) of the differences between the planned and actual model surgery movements are presented in Table 1a,b![]()
, where P < 005 is significant. The mean absolute errors of model surgery movements ignoring the direction can be seen graphically in Figure 4a
.
|
|
|
Simulated osteotomy error
The mean errors of the simulated osteotomies are presented in Table 2
and a graphical presentation of the mean absolute values of the errors in Figure 4b
.
|
Discussion
In the vertical plane the Lockwood technique had an overall mean impaction that was less than that planned. This measured up to 5 mm, whereas the Eastman technique showed no bias in either direction.
In the anteroposterior plane, the Eastman technique was also better than the Lockwood, whereas in the mediolateral (transverse) plane there was no difference.
The results of each skeletal group, presented in Table 1b
, showed no significant difference between skeletal types using the Eastman technique (P > 005). However, in the Lockwood technique differences in the vertical plane, between the three skeletal groups, were significant (P < 005). The Class II division 2 group had the most errors in the vertical plane, with the impaction being generally less than planned.
Two-way analyses of variance showed that differences between the patients in the vertical and anteroposterior plane were highly significant (P < 0001) after the model surgery. These differences were not related to skeletal type, but to the amount of movement; the larger the movement the greater the error.
These results show that both the Lockwood and the Eastman model surgery techniques have inherent inaccuracies with both deviating from the treatment plan. However, as previously stated, the Eastman technique was significantly better than the Lockwood technique in the vertical plane.
Errors were higher in those cases where the planned movements were high (610 mm), and also where there was a planned differential maxillary impaction between the anterior and the posterior segments. These findings are similar to those of Ellis (1990), Cottrell and Wolford (1994), and Bamber and Harris (1995). Each technique had its disadvantages, for example, mounting the models with the facebow registration was troublesome when using the Lockwood technique for patients with a steep occlusal-Frankfort plane angle and requiring large vertical movements. This is because the Lockwood's plaster keyspacers needed to be at least 10 mm thick on top of the model base thickness, so the mounting space within the articulator became inadequate. This problem was encountered in two cases, resulting in the maxillary model base requiring trimming to the minimum thickness. The Angle trimmed edges that serve as reference points for the measurement of the horizontal movements, which are the essence of the Lockwood technique, were therefore lost. We also found that the prescribed keyspacer thickness of 7 mm in the Lockwood technique was inadequate in cases requiring large maxillary impactions.
The Lockwood technique has the theoretical advantage over the Eastman technique of having Angle trimmed parallel sides, which reveals undesired transverse shifts of the maxillary model. The Lockwood technique also does not require a second set of mounted models for the final post-surgical relationship.
Keyspacers were fabricated and the models mounted using plaster mixed with anti-expansion solutions, but even so some degree of dimensional change due to plaster expansion could possibly affect the accuracy of the model surgery in the Lockwood technique. This is not a problem with the Eastman method. In both techniques, segments were held in the post-operative position with sticky wax, which contracts on cooling and thus may have altered the final position of the jaws or segments, introducing some dimensional inaccuracies. This may be the reason for relatively higher error in the vertical plane.
The errors after the simulated surgery were not significantly greater than the model surgery errors, regardless of whether the Lockwood or Eastman wafer was used. In fact, in some cases the simulated osteotomy errors were less than the model surgery error. The direction of the errors was unpredictable, and in some cases the model surgery errors and the simulated surgery errors compensated each other, and resulted in less overall error, as might occur in clinical practice.
Ellis (1990) has also reported statistically significant model surgery errors (absolute values), mean (mm) ± SD: in the anteroposterior plane, 12 ± 09; the vertical plane, 11 ± 12; and mediolateral plane, 19 ± 07. These errors are much higher than the Eastman technique, but less than the Lockwood, as recorded by this study.
It is obvious from the results of previous clinical studies (Pospisil, 1987
; Sarver and Weissman, 1991
; McCance et al., 1992
) that, despite inaccuracies, model surgery planning is essential for operative reproducibility of the treatment plan.
Conclusions
This investigation showed that neither of the two model surgery techniques could carry out the prescribed treatment plan with absolute accuracy. The Eastman technique was relatively better than Lockwood in the vertical and the anteroposterior plane, although the mean differences were small, e.g. less than 1 mm.
The Lockwood technique, in its original form with a simple hinge articulator, is useful for single jaw and segmental surgical procedures, but in bimaxillary osteotomies requiring large complex movements, it was inadequate and unable to record the vertical facial changes accurately. By incorporating a facebow registration and an anatomical articulator in the Lockwood technique for bimaxillary osteotomies the technique is substantially improved. However, for large vertical movements it is inappropriate and does not fit easily within the vertical constraints of the articulator, especially in cases with a steep occlusal-Frankfort plane angle.
Some of the variations from the treatment plan were statistically significant, although anatomically small, but the vertical errors could be clinically significant, i.e. up to 5 mm in the vertical plane with the Lockwood technique. If the planning, surgical, and fixation errors are all within the condyle-meniscus-fossa envelope of adaptation, the anticipated centric occlusion can be achieved. However, if these errors summate, the outcome will result in a postoperative malocclusion. Hence, the need to ensure each stage in the orthognathic process is as accurate as possible. For this reason we do not recommend the modified Lockwood technique.
References
Angle, E. H. (1903) Double resection for treatment of mandibular protrusions, Dental Cosmos, 45, 268274.
Anwar, M. and Harris, M. (1990) Model surgery for orthognathic planning, British Journal of Oral and Maxillofacial Surgery, 28, 393397.
Bamber, M. A. (1995) Recording the facial midline for orthognathic planning, British Journal of Oral and Maxillofacial Surgery, 32, 112114.
Bamber, M. A. and Harris, M. (1995) The role of the occlusal wafers in orthognathic surgery; a comparison of thick and thin intermediate osteotomy wafers, Journal of Craniomaxillofacial Surgery, 23, 396400.[Medline]
Bamber, M. A., Firouzai, R., Harris, M. and Linney, A. (1996) A comparative study of two arbitrary facebow transfer systems for orthognathic surgery planning, International Journal of Oral and Maxillofacial Surgery, 25, 339343.[Medline]
Bamber, M. A., Abang, Z., Ng, W. F., Harris, M. and Linney, A. (1999) The effect of posture and anaesthesia on the occlusal relationship in orthognathic surgery, Journal of Oral and Maxillofacial Surgery, 57, 11641172.[Medline]
Blair, V. P. (1907) Operations on the jaw-bone and face: a study of the aetiology and pathological anatomy of developmental malrelations of the maxilla and mandible to each other and to facial outline and of their operative treatment when beyond the scope of the orthodontist,Surgery, Gynecology and Obstetrics, 4, 6778.
Cotterel, D. A. and Wolford, L. M. (1994) Altered orthognathic surgical sequencing and a modified approach to model surgery, Journal of Oral and Maxillofacial Surgery, 52, 10101020.[Medline]
Ellis, E. (1990) Accuracy of model surgery: evaluation of old technique and introduction of a new one, Journal of Oral and Maxillofacial Surgery, 48, 11611167.[Medline]
Ellis, E., Johnson, D. G. and Hayward, J. R. (1984) Use of the orthognathic surgery simulating instrument in the presurgical evaluation of facial asymmetry, Journal of Oral and Maxillofacial Surgery, 42, 805811.[Medline]
Heggie, A. A. (1987) A calibrator for monitoring maxillary incisor position during orthognathic surgery, Oral Surgery Oral Medicine Oral Pathology, 64, 671673.[Medline]
Hohl, T. H. (1978) The use of an anatomic articulator in segmental orthognathic surgery, American Journal of Orthodontics, 73, 429442.
Hullihen, S. P. (1849) Case of elongation of the under jaw and distortion of the face and neck, caused by a burn, successfully treated, American Journal of Dental Science, 9, 157165.
Kostecka, F. (1931) Some critical remarks on the surgical treatment of anomalies of occlusion,8th International Dental Congress, Paris, 12, 235241.
Krenkle, C. and Lixl G. (1991) Ein modelloperationsgerat zur planung und simulation von OK- und UK- osteotomien, Zahnarztl Prax, 42, 471473.[Medline]
Lindorf, H. H. and Steinhauser, E. W. (1978) Correction of jaw deformities involving simultaneous osteotomy of the mandible and maxilla, Journal of Maxillofacial Surgery, 6, 239244.[Medline]
Lockwood, H. (1974) A planning technique for segmental osteotomies, British Journal of Oral Surgery, 12, 102105.
McCance, A. M., Moss, J. P. and James, D. R. (1992) Le Fort I maxillary osteotomy: Is it possible to accurately produce planned pre-operative movements? British Journal of Oral and Maxillofacial Surgery, 30, 369376.
Peretta, F. M. and Caruso, W. A. (1983) The use of acrylic spacers in orthognathic model surgery, Journal of Oral and Maxillofacial Surgery, 41, 473475.[Medline]
Pospisil, O. A. (1987) Reliability and feasibility of prediction tracing in orthognathic surgery, Journal of Craniomaxillofacial Surgery, 15, 7983.
Sarver, D. M. and Weissman, S. M. (1991) Long term soft tissue response to Le Fort I maxillary superior repositioning, Angle Orthodontist, 38, 267275.
Wassmund, M. (1935)Lehrbuch der praktifchen Chirurgie des Mundes und der Kiefer, Band 1,Verlag Von Hermann Meusser, Leipzig.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |