J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.
Journal of Orthodontics, Vol. 28, No. 3, 237-244, September 2001
© 2001 British Orthodontic Society


Scientific Section

An Ex Vivo Investigation into the Use of a Plasma Arc Lamp When Using a Visible Light-cured Composite and a Resin-modified Glass Poly(Alkenoate) Cement in Orthodontic Bonding

A. P. Pettemerides1, A. J. Ireland2 and M. Sherriff, Bsc3

1 Edgar Buildings Dental Practice, Edgar Buildings, Bath BA1 2EE, UK
2 Department of Orthodontics, Royal United Hospital, Bath BA1 3NG, UK
3 Department of Dental Biomaterials Science, Floor 17, Guy's Tower, London SE1 9KT, UK

A. J. Ireland

Abstract

Objective: To determine the usefulness of the plasma arc lamp in orthodontic bonding when used with both a light curable diacrylate and a resin modified glass poly(alkenoate) cement.

Design: Ex-vivo study.

Method: 160 second premolar teeth were divided into 2 groups. 80 teeth had steel brackets bonded using Transbond XT and 80 were bonded using Fuji Ortho LC. One of four light curing regimes were used, with 20 specimens in each group: (i) 20 seconds curing with a halogen lamp; (ii) 1 second; (iii) 2 seconds or; (iv) 3 seconds with the plasma lamp.

Outcomes: Shear bond tested to failure and the force to debond (N) and locus of bond failure recorded in each case.

Results: Force to debond increases in the case of both bonding materials as the curing time with the plasma lamp increases. The force to debond with 1 and 2 seconds with the plasma lamp was significantly lower in each case. In all instances the force to debond was lower in the case of the resin modified glass poly(alkenoate) cement specimens. Locus of bond failure was unaffected by the method and length of light curing and was generally mixed mode.

Conclusions: Use of the plasma arc lamp in orthodontic bonding could result in significant time saving.

Key words: Plasma Arc Lamp, Halogen Light.

Introduction

Light-cured orthodontic adhesives for bracket bonding have been used for many years (Tavas and Watts, 1979Go) and are reported to have a number of advantages over chemically-cured materials. These include: single paste application, consistent handling characteristics, easy removal of excess material following bracket placement, and a relaxed bonding procedure, leading to more accurate bracket positioning (Read, 1984Go). However, the possible disadvantages include not only the expense of buying the light source, but also the necessity to shine the light for 10–20 seconds at each inter-dental space during curing (Pearson, 1995Go; Sunna and Rock, 1998Go). Attempts have been made to speed up this curing process (Frost et al. (1997) by employing a larger light guide. Despite almost doubling the size of the guide, there appears to be little effect on ex vivo measured force to debond or in vivo bond failure rates. Increasing guide size does, however, significantly reduce the total time of the bonding procedure. Lasers have also been tested as a means of curing orthodontic bonding agents, although 10 seconds per tooth is still required in order to be as effective as 20–40 seconds with the halogen lamp (Kurchak et al., 1997Go; Weinberger et al., 1997Go).

In recent years, the plasma arc lamp has been introduced for use in restorative dentistry, whereas the conventional halogen lamp emits white light, which is subsequently filtered to produce blue light with a wavelength of 400–500 nm and an energy level of approximately 300 mW, the plasma arc lamp (Apollo 95E, Dental Medical Diagnostics, Woodland Hills, CA.) has a much higher peak energy level of 900 mW and a narrower spectrum around 430–490 nm. In restorative dentistry, composite filling material curing times of 30–40 seconds have been reduced to 1–3 seconds by the use of the plasma arc lamp. The plasma arc lamp has preset curing times of 1, 2, and 3 seconds, as well as a 6-second step-cure mode. There is, however, a recharge period of 2 seconds between exposures. Thus, a two-arch bond up from the distal of a second premolar to the contra-lateral second premolar in both arches, with a conventional halogen curing lamp and a recommended 10-second cure time per interspace (20 seconds per tooth), would take 220 seconds. The same number of exposures, including a 2-second recharge interval, with the plasma arc lamp and a 1-second exposure, would take 52 seconds; a 2-second exposure would take 70 seconds and 3-second exposure would take 88 seconds.

The aim of this current ex vivo investigation was to test the effectiveness of the plasma arc lamp in curing a conventional light-cured composite bonding agent, Transbond XT and a resin-modified glass poly(alkenoate) cement, Fuji Ortho LC. The effect of curing time on measured force to debond was investigated along with the locus of bond failure.

Materials and Methods

One-hundred-and-sixty lower second premolar teeth, extracted for orthodontic reasons were used in this experiment and were divided into eight groups of 20 teeth. They were mounted in cold-cure acrylic blocks, using polythene moulds, with their buccal surfaces parallel to, and projecting slightly above the acrylic surface. The blocks measured 15 x 15 x 35 mm in size in order to fit into the custom-made shear bond testing jig (Figure 1Go). The brackets that were bonded to this exposed buccal enamel were 0•022-inch stainless steel lower second premolar brackets (Omni, GAC, Japan). Eighty teeth were bonded with Transbond XT (3M Unitek, St Paul, USA) and 80 with Fuji Ortho LC (GC Corp, Japan). Enamel preparation and bracket bonding was as follows



View larger version (130K):
[in this window]
[in a new window]
 
FIG. 1 The custom made testing jig.

 
Transbond XT Group
  1. The dried tooth surfaces were etched with 37 per cent o-phosphoric acid liquid for 15 seconds.
  2. Rinsed with an air/water spray for 15 seconds.
  3. Dried with oil-free compressed air for 5 seconds until frosty white in appearance.
  4. Transbond XT primer applied to enamel surface and bracket base.
  5. Transbond XT adhesive applied direct to bracket base.
  6. Brackets were then placed on the tooth surface and firm even pressure applied using a Mitchell's trimmer. This was done in order to minimize the adhesive film thickness, as in clinical practice. Excess adhesive was removed from around the margins using a dental probe
  7. The Transbond XT samples were light cured and then shear bond tested to failure after 5 minutes.

Fuji Ortho LC Group

  1. The dry tooth surfaces were primed for 20 seconds with GC Ortho conditioner [10 per cent poly(acrylic acid)].
  2. Rinsed with an air/water spray for 15 seconds.
  3. Light air drying for 5 seconds was performed only in order to remove excess water from the tooth surface. Care was taken to ensure the enamel was left moist.
  4. Fuji Ortho LC capsules were activated and mixed for 10 seconds, and the cement syringed onto the bracket base.
  5. Brackets were positioned on the enamel surface as before using firm even pressure. Excess cement was removed using a dental probe.
  6. The Fuji Ortho LC samples were light cured and shear bond tested to failure after 5 minutes.

In each of these two main groups, 20 specimens of Transbond XT bonded brackets and 20 specimens of Fuji Ortho LC bonded brackets were cured using one of the following light curing regimens:

  1. Halogen lamp (OrtholuxTM XT curing lamp, 3M, St Paul, USA) for 10 seconds mesial and 10 seconds distal to the bracket on the tooth.
  2. Plasma arc lamp: 1 second in total (1 second at the cusp tip above the bracket).
  3. Plasma arc lamp: 2 seconds in total (1 second mesial to the bracket and 1 second distal to the bracket).
  4. Plasma arc lamp: 3 seconds in total (1 second mesial to the bracket, 1 second distal to the bracket, and 1 second at the cusp tip).

Shear bond testing was performed using a custom made testing jig in a Lloyd 2000R testing machine with the cross-head speed set at 2mm/minute. The debond force (N) was recorded in each case, as was the Adhesive Remnant Index (ARI) score (Årtun and Bergland, 1984Go).

Results and Data Analysis

The data were analysed using Stata Release 6 (Stata Corporation, College Station, Texas, USA) and StatXact 3.0.2 (Cytel Corporation). In all analyses, significance was predetermined at {alpha} = 0•05, and the null hypothesis was that force to debond is independent of both material and light source. Scatter plots of the raw force to debond data for each bonding material as a function of light source are given in Figures 2 and 3GoGo, and univariate summary statistics in Table 1Go. The Shapiro–Francia test showed that the raw bond strength data was not normally distributed; however, a square-root transformation resulted in normally distributed data. Kaplan–Meier survival plots for the two bonding agents are shown in Figures 4 and 5GoGo. There was no difference between the halogen lamp for 20 seconds and plasma arc lamp for 3 seconds.



View larger version (19K):
[in this window]
[in a new window]
 
FIG. 2 Scatter plot of force to debond in Newtons of Fuji Ortho LC and the two curing lights: the halogen lamp for 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 


View larger version (19K):
[in this window]
[in a new window]
 
FIG. 3 Scatter plot of force in Newtons required to debond Transbond and the two curing lights: the halogen lamp for 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 

View this table:
[in this window]
[in a new window]
 
TABLE 1 Univariate summary statistics
 


View larger version (21K):
[in this window]
[in a new window]
 
FIG. 4 Kaplan–Meier survival probabilities and log rank tests for Fuji Ortho LC and the two light curing units: the halogen lamp at 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 


View larger version (21K):
[in this window]
[in a new window]
 
FIG. 5 Kaplan–Meier survival probabilities and log rank tests for Transbond and the two light curing units: the halogen lamp at 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 
A two-way analysis of variance showed there to be significant main effects of light-source and bonding agent, but no significant interaction term (Table 2Go). This is confirmed in the plot of cell means for all light source-material combinations (Figure 6Go). A retrospective analysis of the analysis of variance indicated a power >90 per cent for the main effects in the model. Linear contrasts were used to compare light sources and materials (Table 3Go). It can be seen from these contrasts that: (i) the halogen lamp at 20 seconds per tooth is significantly different from the combined plasma arc lamp times; (ii) the halogen lamp is significantly different from the plasma arc at both 1 and 2 seconds per tooth; (iii) there is no significant difference between the halogen lamp at 20 seconds and plasma arc lamp at 3 seconds; and (iv) the two bonding agents are significantly different.


View this table:
[in this window]
[in a new window]
 
TABLE 2 Analysis of variance following square root transformation of the force to debond data. There is no significant material*light interaction
 


View larger version (22K):
[in this window]
[in a new window]
 
FIG. 6 Plot of the cell means of square root of force to debond for all material light combinations. The fact that the lines do not cross indicates no material*light interaction.

 

View this table:
[in this window]
[in a new window]
 
TABLE 3 Contrasts
 
The Kruskal–Wallis one-way analysis of variance (Table 4Go) showed that the locus of bond failure was unaffected by the light source and curing time. Figures 7 and 8GoGo illustrate the adhesive remnant scores for each material, and light source and time combination, which shows bond failure to be largely mixed mode in each case.


View this table:
[in this window]
[in a new window]
 
TABLE 4 Kruskal–Wallis one-way analysis of variance of the Adhesive Remnant Index (ARI) scores
 


View larger version (48K):
[in this window]
[in a new window]
 
FIG. 7 Frequency plot of the Adhesive Remnant Scores (ARI) of Fuji Ortho LC and the two curing lights: the halogen lamp for 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 


View larger version (51K):
[in this window]
[in a new window]
 
FIG. 8 Frequency plot of the Adhesive Remnant Scores (ARI) of Transbond and the two curing lights: the halogen lamp for 20 seconds, and the plasma arc lamp at 1, 2, and 3 seconds.

 
Discussion

The results of this ex vivo experiment demonstrate that, whereas light-curing times of 1 and 2 seconds with the plasma arc lamp produces significantly lower force to debond than 20 seconds with the halogen lamp, the results with the plasma arc lamp at 3 seconds were not significantly different. This is particularly well illustrated in the Kaplan-Meier survival probability plots (Figures 4 and 5GoGo). Not only did the light source and curing time have a significant effect, but as might be expected, there was a significant effect of material on force to debond (Table 2Go). At each curing interval the measured force to debond with the light-cured diacrylate (Transbond XT), was greater than with the resin-modified glass poly(alkenoate) cement Fuji Ortho LC (Figure 6Go). Lower observed force to debond with light-cured resin-modified glass poly(alkenoate) cements compared with diacrylates has been reported previously (Bishara et al., 1999Go; Choo, 1999Go).

Extrapolation of ex vivo results to the in vivo situation is fraught with difficulties. The major problem being that the optimum bond strength for clinical use is still unknown, even though some have suggested minimum bond strength values of 60–80 kg/cm2 (Reynolds, 1979Go) for clinical use. In this current experiment the measured force to debond with Transbond XT was significantly greater than with Fuji Ortho LC, at all the light-curing times and with both light sources. It is known that light-cured resin-modified glass poly(alkenoate) cements can be used clinically with considerable success (Silverman et al., 1995Go), even though the measured force to debond is lower than that observed with diacrylate bonding adhesives. It is possible therefore that the plasma arc lamp may be used successfully in vivo with an even shorter curing time, of perhaps 2 seconds per tooth, when used with Transbond XT. Not only will this save clinical time, but it will also make the bonding procedure more tolerable for the patient and certainly easier for the clinician in cases where moisture control is a problem.

The locus of bond failure, as determined by the ARI scores, was unaffected by the light source or curing time (Table 4Go) and was largely mixed mode (Figures 7 and 8GoGo). Therefore, whatever the light source and curing time, clean-up time at debond will be unaffected.

Although the plasma arc lamp may have a number of advantages in clinical orthodontics over the conventional halogen lamp, it has one major disadvantage. At present the plasma arc lamp is approximately six times the cost of the halogen lamp, although this price difference may reduce with time.

Conclusions

Under the conditions of this experiment the following conclusions were reached:

  1. The Apollo 95E plasma arc lamp, when used for 3 seconds per tooth, produced a force to debond comparable with 20 seconds curing with the OrtholuxTM XT Curing Lamp. This may lead to a considerable time saving during orthodontic bonding procedures.
  2. The measured force to debond increased significantly as did the curing time with the plasma arc lamp from 1 to 3 seconds.
  3. At all light-curing times the measured force to debond with Fuji Ortho LC was significantly lower than with Transbond XT. As a result, it is possible that a curing time of 2 seconds per tooth with the plasma arc lamp may be acceptable when used with Transbond XT.

The locus of bond failure, as measured by the Adhesive Remnant Index score, was unaffected by the nature of the light source or length of the curing time.

A prospective randomized clinical trial is planned in order to assess the performance of Transbond XT and Fuji Ortho LC when cured with the Apollo 95E plasma arc lamp and the Ortholux TM halogen lamp.

Acknowledgments

The authors would like to thank David Rees of T.O.C. Bristol, 3M Unitek UK and GC Corp. UK for their help, and Professor A. Harrison for his permission to use the testing facilities at Bristol Dental School. We would also like to thank the Shirley Glasstone-Hughes Memorial Scholarship for funding this project.

References

Årtun, J. and Bergland, S. (1984) Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment, American Journal of Orthodontics, 85, 333–340.[Medline]

Bishara, S. E., Von Wald, L., Olsen, M. E. and Laffoon, J. (1999) Effect of time on the shear bond strength of glass ionomer and composite orthodontic adhesives, American Journal of Orthodontics and Dentofacial Orthopedics, 116, 616–620.[Medline]

Choo, S. C. (1999)An investigation into the use of resin-modified glass poly(alkenoate) cements as orthodontic bonding agents,MSc Dissertation, University of Bristol.

Frost, T., Norevall, L. I. and Persson, M. (1997) Bond strength and clinical efficiency of two light guide sizes in orthodontic bracket bonding, British Journal of Orthodontics, 24, 35–41.[Abstract]

Kurchak, M., Desantos, B., Powers, J. and Turner, D. (1997) Argon laser for light-curing adhesives, Journal of Clinical Orthodontics, 31, 371–374.

Pearson, A. O. (1995) Optimal light curing of adhesive precoated brackets, Journal of Clinical Orthodontics, 29, 583–585.

Read, M. J. F. (1984) The bonding of orthodontic attachments using a visible light-cured adhesive, British Journal of Orthodontics, 11, 16–20.[Abstract]

Reynolds, I. R. (1979) A review of direct orthodontic bonding, British Journal of Orthodontics, 2, 171–178.

Silverman, E., Cohen, M., Demke, R. S. and Silverman, M. (1995) A new light-cured glass ionomer cement that bonds brackets to teeth without etching in the presence of saliva, American Journal of Orthodontics and Dentofacial Orthopedics, 108, 231–236.[Medline]

Sunna, S. and Rock, W. P. (1998) Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial, British Journal of Orthodontics, 25, 283–287.[Abstract]

Tavas, M. A. and Watts, D. C. (1979) Bonding of orthodontic brackets by trans-illumination of a light-activated composite: an in vitro study, British Journal of Orthodontics, 6, 207–208.[Medline]

Weinberger, S. J., Foley, T. F., McConnell, R. J. and Wright, G. Z. (1997)Bond strengths of two ceramic brackets using argon laser, light and chemically cured resin systems.Angle Orthodontist, 67, 173–182.[Medline]




This article has been cited by other articles:


Home page
J. Orthod.Home page
J. S. Russell, S. J. Littlewood, A. Blance, and L. Mitchell
The efficacy of a plasma arc light in orthodontic bonding: a randomized controlled clinical trial
J. Orthod., September 1, 2008; 35(3): 202 - 209.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pettemerides, A. P.
Right arrow Articles by Sherriff, M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS