Scientific Section |
1 Department of Orthodontics, St Luke's Hospital, Little Horton Lane, Bradford, UK
2 Sub-unit for Medical Statistics, Epidemiology & Health Services Research, 7175 Clarendon Road, University of Leeds, Leeds, UK
Abstract
Objective: To compare the clinical failure rates of brackets bonded using a prototype hydrophilic primer, designed to be insensitive to moisture, with brackets bonded with a conventional primer.
Design: Single centre randomised controlled clinical study. Thirty-three patients were bonded using a split mouth technique: randomly allocating the hydrophilic primer to one side of the mouth and a conventional primer to the other.
Setting: Hospital orthodontic department, Bradford, UK.
Subjects: Orthodontic patients requiring fixed appliances
Main outcome measures: The site and time to bond failure was recorded for each bracket that failed over 6 months.
Results: Using survival analysis, there was an increased risk of bracket failure when bonded with the hydrophilic primer compared with the conventional primer (hazard ratio = 22, 95% confidence interval: 11 to 45, P = 001).
Conclusions: This hydrophilic primer cannot be recommended for routine clinical use.
Key words: Hydrophilic Primer, Moisture Insensitive Primer, Orthodontic Bonding, Randomised Controlled Trial
Introduction
Composite resin is at present the most effective and reliable adhesive available for bonding orthodontic attachments (Turner, 1996
). It fulfils many of the requirements of an ideal bonding agentbiocompatible, adequate bond strength, long shelf life, good colour stabilitybut it is technique sensitive. Good technique is required to avoid moisture contamination, which is considered to be one of the commonest reasons for bond failure (Kinch et al., 1988
; Wang and Lu, 1991
).
A previous paper (Littlewood et al., 2000
) reviewed the literature on bonding in the presence of moisture and reported an in vitro study of a hydrophilic primer used for orthodontic bonding. This prototype primer has been developed by 3M Unitek to overcome the problems of moisture contamination when bonding orthodontic attachments with composite resin.
The aim of the present study was to assess the clinical performance of brackets bonded with the new hydrophilic primer compared with brackets bonded with a conventional primer. The study, therefore, addressed the following null hypothesis: there is no difference in the clinical failure rate of brackets bonded with the hydrophilic primer compared to those bonded with a conventional primer.
Materials and methods
Subjects
The subjects were patients taken consecutively off the waiting list for orthodontic treatment at St Luke's Hospital, Bradford, UK. They were eligible for the study if they fulfilled the following inclusion criteria:
Ethical approval
This was obtained from the Bradford Local Research Committee (5th December 1995). Written patient and parental consent were obtained.
Assignment
A split mouth design was used, bonding one side of the mouth with the hydrophilic primer and the other side with the conventional primer. The sides were allocated randomly using random number tables. The side (right or left) to be used for the hydrophilic primer was sealed in pre-ordered individual envelopes, which were opened after the patient had been accepted onto the trial. The generator and executor of the randomization were separate individuals.
Interventions
Two types of primer were used for bonding the brackets:
An Ortholux XT® (3M Unitek) visible light-curing unit was used for polymerization.
Bonding procedure
All brackets were bonded by the same operator (SL) following this procedure:
Incisors, canines, and premolars were bonded. Molars were banded.
Blinding
The patient was not aware which primer was on which side of the mouth. As the consistency of the primers were different it was not possible to blind the operator to the type of primer used on each side of the mouth.
Data collection
Each subject was monitored for 6 months. If a bond failed the following was recorded:
Statistical analysis
To overcome the fact that not all brackets failed by the end of 6 months, a survival analysis was used. The first bracket to fail on each side was recorded and used in analyses. KaplanMeier estimates of survival curves were constructed and compared using the log rank test, stratifying by patient. In this way, the dependence of teeth within the same mouth was accounted for.
Sample size
To have adequate power (80%) to show a statistically significant difference (P < 005) in proportions with at least one failed bracket after 6 months, the RCT needed 33 patients in each group using a log rank test ignoring the matching. This assumes a difference of 35 percentage points (45% versus 80%, hazard ratio = 36). As an approximate allowance for the effect of matching, an estimated 33 patients in total were required using a stratified log rank test for analysis.
Results
Profile of randomized controlled trial
Thirty-three patients fulfilled the inclusion criteria and were entered into the trial and a further four patients were excluded on the following grounds:
one refused to give consent to take part in the study;
one was an adult (over 18 years of age);
two required functional appliance therapy.
The primers were randomly allocated to all 33 patients according to the split mouth design, with 266 brackets randomly allocated to each type of primer. In total 532 brackets were bonded. All 33 patients received the standard intervention as allocated and were followed up for the full 6 months (Figure 1
).
|
|
|
Distribution of bond failure
Figure 3
shows that in all areas of the mouth, the failure rate was equal or greater for each tooth type when using the hydrophilic primer. Even in areas where moisture contamination is more likely, more posteriorly, the hydrophilic primer still produced more failures.
|
Principle findings
The brackets bonded with the hydrophilic primer failed more frequently than those bonded with the conventional primer. The brackets bonded with the hydrophilic primer had double the risk of failure at any point over the subsequent 6 months than those bonded with the conventional primer (hazard ratio = 22).
Strengths and weaknesses of study
The purpose of using a prospective randomized approach in this study was to try and eliminate as much bias as possible, although weaknesses do exist. Unfortunately, the operator could not be blinded to the type of primer used, due to the difference in the consistency of the two primers. Secondly, although the primer was allocated randomly to each side of the mouth, this could incur a certain bias if one side of the mouth was more prone to failures than the other. This could have been overcome by randomly allocating to quadrants of the mouth.
Comparison with previous studies
It is difficult to make direct comparisons between studies due to the variety of techniques, materials, research designs and trial duration. Previous studies have shown failure rates of between 423 % (Cavina, 1977
; Gorelick, 1977
; Zachrisson, 1977
; Zachrisson and Brobakken, 1978
; Lovius et al., 1987
; Kinch et al., 1988
; O'Brien et al., 1989
; Millett and Gordon, 1994
). The APC brackets used in the study have composite based on Transbond adhesive. Hence, the research that bears the closest similarity to this study is a 5-year review of brackets bonded with Transbond, producing an overall failure rate of 6% (Millett et al., 1998
). Certainly, the failure rate of the brackets bonded with the conventional primer (68% over 6 months) would appear to be comparable. This would imply therefore that the high failure rate of the hydrophilic primer (188%) is due to the product itself, rather than a reflection of the methodology.
Implications of the research
The clinical study clearly indicates that this new hydrophilic primer cannot be recommended for clinical use. It confirms the findings of a previous laboratory study (Littlewood et al., 2000
).
In a review of orthodontic bonding in 1975 Reynolds proposed that a maximum bond strength of 6080 kg/cm3 (68 MPa) would be required for successful clinical bonding, but that adhesives with an in vitro bond strength of approximately 50 kg/cm3 (5 MPa) would be sufficient. These figures have been quoted on many occasions since then. The findings of this prospective clinical trial, and the previous laboratory study (Littlewood et al., 2000
) using the same materials and methods, allows these assumptions to be reassessed.
Brackets bonded with a conventional primer produced a clinical failure rate of 68 % over 6 months. The laboratory study using these materials produced a median bond strength of 871 MPa. However, it is the lower values of the bond strength distribution that govern the likelihood of clinical failure. The bond strength for a 5% chance of failure, a more appropriate level at which to assess bond strength, was 54 MPa. It is proposed, therefore, that the bond strength of a material with a 5% chance of failure should be at least 54 MPa. In future laboratory bond strength studies calculating the bond strength for a 5% chance of failure will allow comparison to this figure.
Future research
There is no doubt that a primer that allows bonding with composite in moist conditions would be useful, especially in areas where moisture control is difficult, such as lower second permanent molars and partially erupted teeth. It would appear that a primer with a different chemical composition to the one used here is required. 3M Unitek have developed a different version of this primer, which may warrant research.
Conclusions
Brackets bonded with this prototype hydrophilic primer had double the risk of failure over 6 months as those bonded using with the conventional primer. The hydrophilic primer cannot therefore be recommended for clinical use.
Acknowledgments
We would like to thank the patients and staff at St Luke's hospital who were involved with this study. We would also like to thank Bridget Doubleday for additional statistical advice. Finally, we would like to acknowledge the support of 3M Unitek, who generously provided all the orthodontic bonding materials throughout, whilst respecting the completely independent nature of the research.
References
Cavina, R. A. (1977) Clinical evaluation of direct bonding, British Journal of Orthodontics, 4, 2931.[Medline]
Gorelick, L. (1977) Bonding metal brackets with a self-polymerizing sealant-composite: a 12-month assessment, American Journal of Orthodontics and Dentofacial Orthopedics, 71, 542553.
Kinch, A. P., Taylor, H., Warltier, R., Oliver, R. G. and Newcombe, R. G. (1988) A clinical trial comparing the failure rates of directly bonded brackets using etch times of 15 or 60 seconds, American Journal of Orthodontics and Dentofacial Orthopedics, 94, 476483.[Medline]
Littlewood, S. J., Mitchell, L., Greenwood, D. C., Bubb, N. L. and Wood, D. J. (2000) Investigation of a hydrophilic primer for orthodontic bonding: an in vitro study, British Journal of Orthodontics, 27, 181186.
Lovius, B. B. J., Pender, N., Hewage, S., O'Dowling, I. and Tomkins, A. (1987) A clinical trial of a light activated bonding material over an 18 month period, British Journal of Orthodontics, 14, 1120.[Abstract]
Millett, D. T. and Gordon, P. H. (1994) A 5-year clinical review of bond failure with a no-mix adhesive (Right on®), European Journal of Orthodontics, 16, 203211.
Millett, D. T., Hallgren, A., Cattanach, D., McFadzean, R., Pattison, J., Robertson, M. and Love, J. (1998) A 5-year clinical review of bond failure with a light-cured resin adhesive, Angle Orthodontist, 68, 351356.[Medline]
O'Brien, K. D., Read, M. J. F., Sandison, R. J. and Roberts, C. T. (1989) A visible light-activated direct-bonding material: an in vivo comparative study, American Journal of Orthodontics and Dentofacial Orthopedics, 95, 348351.[Medline]
Reynolds, I. R. (1975) A review of direct orthodontic bonding, British Journal of Orthodontics, 2, 171178.
Turner, P. J. (1996) Successful bonding in orthodontics, Part 1, Dental Update, 23, 366370.[Medline]
Wang, W. N. and Lu, T. C. (1991) Bond strength with various etching times on young permanent teeth, American Journal of Orthodontics and Dentofacial Orthopedics, 100, 7279.[Medline]
Zachrisson, B. U. (1977) A posttreatment evaluation of direct bonding in orthodontics, American Journal of Orthodontics and Dentofacial Orthopedics, 71, 173189.
Zachrisson, B. U. and Brobakken, B. O. (1978) Clinical comparison of direct versus indirect bonding with different bracket types and adhesives, American Journal of Orthodontics and Dentofacial Orthopedics, 74, 6278.
This article has been cited by other articles:
![]() |
N. A. Wenger, S. Deacon, and N. W. T. Harradine A randomized control clinical trial investigating orthodontic bond failure rates when using Orthosolo universal bond enhancer compared to a conventional bonding primer J. Orthod., March 1, 2008; 35(1): 27 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Wendl, H. Droschl, and P. Muchitsch Indirect bonding--a new transfer method Eur J Orthod, February 1, 2008; 30(1): 100 - 107. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Reis, J. E. d. Santos, A. D. Loguercio, and J. R. de Oliveira Bauer Eighteen-month bracket survival rate: conventional versus self-etch adhesive Eur J Orthod, February 1, 2008; 30(1): 94 - 99. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Manning, S. M. Chadwick, D. Plunkett, and T. V. Macfarlane A randomized clinical trial comparing 'one-step' and 'two-step' orthodontic bonding systems J. Orthod., December 1, 2006; 33(4): 276 - 283. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Murfitt, A. Quick, M. Swain, and G. Herbison A randomised clinical trial to investigate bond failure rates using a self-etching primer Eur J Orthod, October 1, 2006; 28(5): 444 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mavropoulos, A. Karamouzos, G. Kolokithas, and A. E. Athanasiou In vivo evaluation of two new moisture-resistant orthodontic adhesive systems: a comparative clinical trial J. Orthod., June 1, 2003; 30(2): 139 - 147. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||