|
|
||||||||
Scientific Section |
Newcastle Dental School, UK
Professor J. F. McCabe, Dental Materials Science Unit, Newcastle Dental School, Framlington Place, Newcastle Upon Tyne NE2 4BW, UK. Email: j.f.mccabe{at}ncl.ac.uk
Abstract
Objective: This study investigates the shear-peel orthodontic bond strengths of brackets bonded with an unfilled acrylic resin containing 4-META (MCP Bond®) or a no-mix composite adhesive (Right On®) to acid-etched or sandblasted enamel.
Design: Ex vivo.
Materials and methods: Eighty human pre-molar teeth were separated into four equal groups, according to the adhesive used and method of enamel pre-treatment. Group IRight On® with enamel etched using phosphoric acid for 30 seconds. Group IIRight On® with enamel sandblasted using 50-µm alumina particles at 80 psi for 3 seconds. Group IIIMCP Bond® with enamel etched using phosphoric acid for 30 seconds. Group IVMCP Bond® with enamel sandblasted using 50-µm alumina particles at 80 psi for 3 seconds. Subsequently, the specimens were stored in distilled water for 24 hours prior to bond strength testing using an Instron® universal testing machine. Each debonded tooth was scored using the adhesive remnant index (ARI) to determine the site of bond failure.
Results: The mean bond strength (1 SD) were Group I: 10.7 (2.7) MPa, Group II: 5.3 (1.3) MPa, Group III: 15.9 (3.4) MPa, Group IV: 15.0 (2.2) MPa. Statistical analysis using one-way analysis of variance and Tukey test found no statistical difference between Group III and Group IV (P > 0.05), but the other groups were statistically different from each other (P < 0.05). The data were found to fit the Weibull distribution and Weibull analysis showed stress required for a 5 per cent probability of failure was: Group I: 5.77 MPa; Group II: 3.32 MPa; Group III: 10.31 MPa; Group IV: 10.58 MPa. Chi-square test showed a statistically significant difference existed between the ARI scores (P < 0.001), principally through less adhesive remnants being observed on the sandblasted specimens.
Conclusion: The adhesive containing 4-META achieved significantly higher bond strengths than the composite adhesive, particularly in the case of sandblasted enamel.
Key words: 4-META, acid-etching, acrylic, orthodontic bonding, sandblasting
Introduction
Orthodontic brackets are routinely bonded to enamel using the acid-etch technique in conjunction with a composite-type orthodontic adhesive. Several alternative approaches to bonding, including the use of different enamel preparations1
3
and adhesive systems4
8
have been investigated, with the exception of resin modified glass ionomer cements,5 they have not yet achieved the success required in order to justify their routine clinical use. Both the procedure used for enamel surface preparation1
3
, and the nature of the adhesive6
10
can affect the reliability of the bond, the ease of de-bond and the ease of enamel clean-up procedures at the end of treatment.
Recently, sandblasting has been introduced into dentistry as a means of surface preparation for bonding11
13
. Furthermore, adhesion promoters such as 4-META (4-methacryloxyethyl trimelliticanhydride; Figure 1
) used in conjunction with an unfilled resin offer the potential of adequate bonding combined with easy de-bond and clean-up at the end of treatment.
|
Materials and methods
Tooth sample, grouping and mounting procedure
Eighty non-carious premolar teeth, extracted for orthodontic purposes from patients under the age of 18 years, were collected from three sources in the Northumbria region (Sunderland, Newcastle, and Gateshead). The teeth were stored separately, according to their source and extraction date, in 0.5 per cent (w/v) chloramine-T solution for 1 month at room temperature before being transferred into distilled water and refrigerated at 4°C before use. All teeth were stored for at least 1 month prior to bond strength testing and teeth not used within 6 months of their extraction date were discarded.14
All teeth were examined under x4 magnification to assess whether damage had occurred to the enamel surface during the extraction process. Any damaged teeth were discarded.
To minimize potential variability in the shear bond strength analysis resulting from tooth type15
, each experimental group was allocated 20 premolars in a stratified manner according to premolar nomenclature and tooth source, so each group had the same quantity of premolar types from each source.
In order to aid retention of a tooth in its mounting, each root was grooved using a high-speed bur. The vertically positioned tooth was then mounted in a polyester resin to a level 1 mm below the cemento-enamel junction. Possible dehydration of the tooth during the curing of the polyester resin was minimized by storing the mounted tooth in a humidity chamber at room temperature for 4 hours, by which time the resin had reached its initial set. The mounted tooth was then immersed in distilled water at room temperature, where the resin underwent a complete cure. The polyester resin mounting blocks were later trimmed so that the specimens could be mounted in a vice during bond strength testing. Particular attention was paid to ensure that the vertical axis of the tooth and bucco-lingual axis of the crown were parallel to the trimmed (clamping) sides of the resin-mounting block. Once these had been trimmed, the tooth/resin-mounting block was returned to distilled water and refrigerated to await bonding.
Adhesives used
Two types of orthodontic adhesives were evaluated in the current study and used according to the manufacturers instructions:
Enamel pretreatment
Two different methods of enamel pre-treatment were used:
Experimental groups
The four groups used were as follows:
Bracket placement technique
Premolar brackets (Ovation®, GAC) with a foil mesh base and an average base area of 14.93 ± 0.21 mm2 and 15.26 ± 0.15 mm2 for upper and lower brackets, respectively, were used. Bracket placement was performed at room temperature, i.e. 21 ± 2°C. Each bracket was positioned on the mid coronal point of the tooth and to avoid the entrapment of air within the adhesive, the bracket was initially placed along its gingival edge before being fully seated with a rolling action. Firm pressure was applied to minimize the adhesive thickness and careful attention paid to ensure that adhesive extruded from the entire bracket base perimeter, thereby confirming the entire bonding surface was covered with adhesive. Any excess adhesive visible to the naked eye was removed immediately with a sharp straight probe. After bonding, all specimens were immersed in distilled water maintained at 37°C for 24 hours to await shear-peel bond strength testing.
Bond strength testing
The shear-peel bond strength was determined using an Instron® universal-testing machine. The specimens were removed from the distilled water, dried, and immediately mounted on the testing machine. The resin mounting block was positioned in the vice clamps so that the bracket base was vertical in all planes and directly below the load cell. A 0.8-mm diameter round stainless steel wire loop was attached via a universal joint to the load cell at one end and placed under the gingival tie wings adjacent to the bracket base at the other end. This ensured that the force vector was as near as possible parallel to the bracket base. Using a crosshead speed of 1 mm per minute, the shear force required to dislodge the bracket was measured.
Analysis of the site of bond failure
Debonded teeth and brackets were examined under x30 magnification to evaluate and categorize the site of bond failure. Any excess adhesive retained around the bracket base periphery was ignored when considering the quantity of retained adhesive.16
A modified version of the ARI1 was used to assess the amount of resin retained on the enamel surfaces after debonding. The ARI categories used were:
Any enamel fractures that occurred during debonding were also recorded.
Statistical analysis
Descriptive statistics, including mean, standard deviation, and minimum and maximum stress values were calculated for each of the experimental groups. One-way analysis of variance (ANOVA) was used to determine whether significant differences existed between the means of the various experimental groups. To determine if the means were significantly different from each other, a Tukey test was employed at the chosen level of probability (P < 0.05). Weibull analysis was used to calculate the Weibull modulus, characteristic strength and the required stress for 1 and 5 per cent probabilities of failure.
Chi-square test was used to determine any significant differences between experimental groups ARI scores.
Scanning electron micrograph specimen preparation
For each adhesive system tested, a bonded specimen was placed in 10 per cent hydrochloric acid to dissolve the tooth. The resin impression (negative) of the enamels pretreated surface was examined by a scanning electron microscope to demonstrate the quality of micro-mechanical retention achieved by each adhesive system.
Results
The mean shear bond stress, standard deviations, minimum and maximum stress values are tabulated for each experimental group in Table 1
. One-way analysis of variance revealed a statistically significant difference between the mean values (P < 0.001) and Tukey test showed that there was a statistically significant difference (P < 0.05) between all experimental groups except MCP Bond®/etched and MCP Bond®/sandblasted.
|
|
|
2) test was invalid as a number of the observed frequencies were less than 1 and more than 20 per cent of expected frequencies were less than 5. Pooling of ARI scores 1 and 2 and comparing these with ARI score 3 alone showed that there was a significant difference among the four groups (P < 0.001). The data distribution here indicated that bond failures for experimental groups with etched enamel were observed more frequently at the bracket-adhesive interface, as compared to the experimental groups with sandblasted enamel.
|
|
|
|
|
|
Reynolds17
has suggested that for an adhesive system to have acceptable clinical performance in vitro bond strengths between 6 and 8 MPa are required. Using these values for this study, Right On®/etched would have a clinical failure rate of around 5 per cent, which can be considered acceptable. Right On®/sandblasted adhesive system is unlikely to be acceptable clinically, as its bond strengths were significantly lower than Right On®/etched and this concurs with previous research3,
18
21
. However, both MCP Bond®/etched and MCP Bond®/sandblasted adhesive systems showed potentially favourable bond strengths and warrant further discussion.
Analysis of the surface topography of sandblasted enamel3
20
has shown it has a uniform roughness (Figures 5 and 7![]()
) that is comparable to acid-etched enamel. Furthermore, the etch patterns achieved using acid-etching have been shown to be somewhat unreliable22
(Figures 4 and 6![]()
). A greater consistency in the surface roughness achieved by sandblasting compared with etching may explain the greater consistency (lower variance) of bond strengths seen in this study for sandblasted enamel compared with etched enamel.
The increased bond strengths achieved with MCP Bond® were most likely a result of it being an unfilled acrylic material containing 5 per cent 4-META monomer.23
4-META is a difunctional monomer exhibiting a hydrophobic methacrylate group and a hydrophilic aromatic anhydride group. Functionally, the hydrophobic methacrylate group is able to combine with resins in composite/acrylic adhesives, whilst the hydrophilic aromatic anhydride group is able to promote adhesion to the tooth surface. It is thought that increased bond strengths are achieved through an ability of 4-META to enhance diffusion into the tooth surface.23,
24
Such a mechanism would explain why bond strengths with MCP Bond® are higher than with the relatively hydrophobic Right On® adhesive. When comparing resin impressions of both Right On® and MCP Bond® to sandblasted enamel (Figures 5 and 7![]()
) no apparent difference is visible, however, further detailed investigation is required before this can be fully determined.
In this study the ARI was used to characterize the site of bond failure. It was observed that acid-etching of enamel resulted in larger amounts of adhesive residue on the enamel surface after de-bonding compared with sandblasted enamel, confirming previous findings.3,
18,
19
However, in the current work some adhesive remnants were also present in the Right On®/sandblasted group.
The bond strengths achieved by MCP Bond®/etched and MCP Bond®/sandblasted adhesive systems were greater than those of the control and in the MCP Bond®/ etched group this sometimes led to enamel damage (Figure 3
). While MCP Bond®/sandblasted results in bond failure principally along the enamel/adhesive interface, the stresses created at this interface did not result in any enamel fractures. Clinical debonding forces, whether accidental or deliberate, do differ from the in vitro forces used in this study. However, the performance of the MCP Bond®/sandblasted adhesive system, with its relatively soft acrylic resin, offers an easy and safe debond and clean-up procedure, and these attributes would warrant further investigation.
Two principal concerns arise over the use of intra-oral sandblasting, namely the amount of enamel lost during enamel preparation, and the health and safety issues arising as a result of the potential inhalation of alumina particles. There is relatively little evidence available to indicate the enamel damage which may result from sandblasting, but where it exists, it would suggests that it is potentially no worse than acid-etching.21
As rubber dam isolation is not practical in orthodontics, the inhalation of alumina particles is potentially hazardous unless other adequate precautions are taken. Further work is now required to develop a sandblasting protocol, which can be used safely and effectively in orthodontics.
Conclusion
The results from this investigation indicate that:
Acknowledgments
The authors would like to acknowledge Mr T. E. Carrick and Mrs S. Rusby for their invaluable assistance during specimen testing and Dr T. Booth for his assistance with scanning electron microscopy.
References
1 Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pre-treatment. Am J Orthod 1984; 85: 333340.[CrossRef][Medline]
2 Fraunhofer JA, Allen DJ, Orbell GM. Laser etching of enamel for direct bonding. Angle Orthod 1993; 63: 7376.[Medline]
3 Sargison AE, McCabe JF, Millett DT. A laboratory investigation to compare enamel preparation by sand blasting and acid etching prior to bracket bonding. Br J Orthod 1999; 26: 141146.
4 Norevall LI, Marcusson A, Persson M. A clinical evaluation of a glass ionomer cement as an orthodontic bonding adhesive compared with an acrylic resin. Eur J Orthod 1996; 18: 373384.
5 Fricker JP. A 12 month clinical evaluation of a light activated glass ionomer cement for the direct bonding of orthodontic brackets. Am J Orthod Dentofacial Orthop 1994; 105: 502505.[Medline]
6 Moin K, Dogon IL. An evaluation of shear strength, measurements of unfilled and filled combinations. Am J Orthod 1978; 74: 531535.[CrossRef][Medline]
7 Kusai Al-Munajed M, Gordon PH, McCabe JF. The use of a cyanoacrylate adhesive for bonding orthodontic brackets: an ex vivo study. J Orthod 2000; 27: 255260.
8 Ireland AJ, Sherriff M. Use of an adhesive resin for bonding orthodontic brackets. Eur J Orthod 1994; 16: 2734.
9 Cook PA, Youngson CC. An in vitro study of the bond strength of glass ionomer cement in the direct bonding of orthodontic brackets. Br J Orthod 1988; 15: 247253.[Abstract]
10 Pus MD, Way DC. Enamel loss due to orthodontic bonding with filled and unfilled resins using various clean-up techniques. Am J Orthod 1980; 80: 269283.
11 Zachrisson BU, Büyükyyilmaz T. Recent advances in bonding to gold, amalgam and porcelain. J Clin Orthod 1993; 27: 661675.
12 Millet DT, McCabe JF, Gordon PH. The role of sandblasting on the retention of metallic brackets applied with glass ionomer cement. Br J Orthod 1993; 20:117122.[Abstract]
13 Wood DP, Paleczny GJ, Johnson LN. The effect of sandblasting on the retention of orthodontic bands. Angle Orthod 1996: 66: 207214.[Medline]
14 ISO/TR 11405. Dental Materials Guidance on Testing of Adhesion to Tooth Structure. Technical report 1994(E).
15 Hobson RS, McCabe JF, Hogg SD. Bond strength to surface enamel for different tooth types. Dent Mat 2001; 17: 184189.[CrossRef]
16 OBrien KD, Watts DC, Read MJF. Residual debris and bond strengthis there a relationship. Am J Orthod Dentofac Orthop 1988; 94: 222230.[CrossRef][Medline]
17 Reynolds IR. A review of direct orthodontic bonding. Br J Orthod 1975; 2: 171178.
18 Olsen ME, Bishara SE, Damon P, Jakobsen JR. Comparison of shear bond strength and surface structure between conventional acid etching and air abrasion of human enamel. Am J Orthod Dentofac Orthop 1997; 112: 502506.[CrossRef][Medline]
19 Canay
, Kocadereli I, Akça E. The effect of enamel air abrasion on the retention of bonded metallic orthodontic brackets. Am J Orthod Dentofac Orthop 2000; 117: 1519.[CrossRef][Medline]
20 Reisner KR, Levitt HL, Mante F. Enamel preparation for orthodontic bonding: a comparison between the use of a sandblaster and current techniques. Am J Orthod Dentofac Orthop 1997; 111: 366373.[CrossRef][Medline]
21 Waveren Hogervorst WL, Feilzer AL, Prahl-Andersen B. The air-abrasion technique versus the conventional acid-etching technique: a quantification of the surface enamel loss and comparison of shear bond strength. Am J Orthod Dentofac Orthop 2000; 117: 2026.[CrossRef][Medline]
22 Mattick CR, Hobson RS. A comparative micro-topographical study of the buccal enamel of different tooth types. J Orthod 2000; 27: 143148.
23 Hotta K, Mogi M, Mura F, Nakabayashi N. Effect of 4-MET on bond strength and penetration of monomers into enamel. Dent Mat 1992; 8: 173175.
24 Nakabayashi N. Biocompatibility and promotion of adhesion to tooth substrates. CRC Critic Rev Biocompat 1984; 1: 2552.
Received January 10, 2002; accepted March 21, 2002
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |