J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mavropoulos, A.
Right arrow Articles by Athanasiou, A. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mavropoulos, A.
Right arrow Articles by Athanasiou, A. E.
Journal of Orthodontics, Vol. 30, No. 2, 139-147, June 2003
© 2003 British Orthodontic Society


Scientific Section

In vivo evaluation of two new moisture-resistant orthodontic adhesive systems: a comparative clinical trial

A. Mavropoulos, A. Karamouzos, G. Kolokithas and A. E. Athanasiou

School of Dentistry, Aristotle University of Thessaloniki, Greece

Professor Athanasios E. Athanasiou, Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece. Email: aeathan{at}dent.auth.gr


    Abstract
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
Objective: To evaluate and compare the clinical performance of two new moisture-resistant orthodontic adhesive systems: a chemically-cured composite resin (Unite, 3M Unitek, Monrovia, California, USA) in conjunction with a special moisture-resistant primer (Transbond MIP, 3M Unitek, Monrovia, California, USA); and a fluoride-releasing light-cured compomer (Assure, Reliance Orthodontic Products, Inc., Itasca, Illinois, USA).

Design: Randomized controlled clinical trial using the ‘split-mouth’ technique.

Setting: Department of Orthodontics, Aristotle University of Thessaloniki.

Subjects (Materials) and Methods: Twenty-five consecutively started patients (13 females and 12 males) requiring fixed appliance orthodontic treatment.

Interventions: Four-hundred-and-thirty-six stainless steel brackets bonded to all teeth except molars using two different moisture-resistant orthodontic adhesive systems.

Main outcome measures: Bond failure rates during a period of 9 months were estimated for each adhesive system and the corresponding bracket survival curves were plotted using the Kaplan– Meier product-limit estimate. Bracket survival distributions with respect to adhesive material, tooth location, patient’s gender and operator, were then compared by means of a log-rank test. Bond failure interface was determined using the Adhesive Remnant Index.

Results: Assure recorded a higher bond failure rate (13.8 per cent) than Unite & MIP (7.3 per cent). The corresponding bracket survival curves were found to be significantly different (P < 0.05). Premolars exhibited higher bond failures than incisors and canines (P < 0.001), while half (49.8 per cent) of the total bond failures occurred during the first 2 months of treatment. The predominant mode of failure was within the bonding material.

Conclusion: The new moisture-resistant adhesive systems under study were found to be clinically efficient, though Assure exhibited a significantly higher bond failure rate than Unite and Transbond MIP. The higher frequency of adhesive failures observed with Assure might indicate a possible weak point at the adhesive-bracket interface.

Key words: Clinical trial, moisture-resistant adhesive, orthodontic bonding.


    Introduction
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
Most of the current orthodontic bonding materials are composite resins based on the bis-GMA formula. Although the use of these materials is well accepted, one major problem is the need for obtaining and maintaining a completely dry operating field throughout the bonding procedure.1Go This is important because moisture contamination of the enamel surface is regarded as the commonest reason of bond failure.2Go

Moisture control, however, can be a problem during bonding in hard-to-reach areas, such as second molars, lower premolars, and partially erupted teeth, or in extreme situation, such as recently exposed impacted canines. This is reinforced by the fact that a number of clinical studies have reported higher probability of bond failure for the lower and the posterior teeth.3–Go5Go

This has resulted in an increasing interest by manufacturers to introduce orthodontic bonding systems that can perform in the presence of moisture. One recent development has been an orthodontic primer (Transbond MIP, 3M Unitek, Monrovia, California, USA), which is claimed to be capable of achieving sufficient bond strength even if the etched enamel surface has been contaminated with moisture. This material is chemically identical to a hydrophilic dentin-bonding agent (Single Bond, 3M Unitek, Monrovia, California, USA) and contains 2-hydroxyethyl methacrylate, polyalkenoate co-polymers with carboxylate groups, and ethanol.6Go The manufacturer recommends its use in conjunction with chemically- or visible light-cured resin adhesives.

Another recently introduced orthodontic adhesive (Assure, Reliance Orthodontic Products, Inc., Itasca, Illinois, USA) is marketed as both moisture-resistant and fluoride-releasing. Assure is a light-cured polyacid-modified composite resin or compomer. Compomers are single-component systems consisting of aluminosilicate glass in the presence of carboxyl-modified resin monomers and light-activated conventional resin monomers.7Go They were developed to bring the advantages of glass ionomer cements (fluoride release, chemical adhesion, or chelation) to resin based adhesives.

There are already a few in vitro studies that aim to estimate the shear bond strength of these two novel orthodontic systems.6,Go8–Go12Go Although these in vitro measurements of shear bond strength provide useful information about the bonding efficiency of different types of materials, they should be interpreted with caution because of inherent limitations and because they cannot take into account a number of factors that play an important role in the mouth.13Go Therefore, they may not be fully representative of the clinical reality.

The aim of the present randomized clinical trial was to evaluate and compare the clinical performance of Unite and Transbond MIP, and Assure, when used for direct bonding of orthodontic brackets. The null hypothesis was that there was no difference in bracket survival distribution for brackets bonded with either bonding agent, during a specified period of active orthodontic treatment.


    Materials and Methods
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
Sample
The subjects of this study were patients seeking treatment at the Department of Orthodontics, School of Dentistry, Aristotle University of Thessaloniki. Following ethical approval, 25 consecutive patients (13 females and 12 males, age range: 10–17 years) who required orthodontic therapy by means of fixed appliances, were selected and treated by the first two authors. The adhesives were randomly allocated using the split-mouth design. Enrolment had as a prerequisite the informed consent of the patients. The mouth of each patient was divided into quadrants and the contralateral bonding pattern was randomly alternated from patient to patient in order to assure an equal distribution of adhesives between the right and the left side of the dental arches. All teeth, except the molars, were directly bonded. The selection criterion was the absence of occlusal interferences on any of the bonded brackets, chosen in an effort to eliminate the influence of trauma on failure rate. Enamel surfaces presenting caries, fillings, or gingival hyperplasia were likewise excluded from the study. Bracket failures caused by known operator error were immediately excluded from the calculation.

Half of the brackets were bonded using a no-mix chemically cured composite resin (Unite, 3M Unitek, Monrovia, California, USA) in conjunction with a special moisture-resistant primer (Transbond MIP, 3M Unitek, Monrovia, California, USA). The remaining half were bonded with a fluoride-releasing light-cured moisture-resistant compomer (Assure, Reliance Orthodontic Products Inc, Itasca, Illinois, USA). The same brackets were used with both adhesives and were twin stainless steel edgewise brackets (Mini, Forestadent, Pforzheim, Germany).

Method
A standardized protocol of tooth preparation and bracket bonding was adopted for all the patients. After fitting and cementing molar bands onto the first and second permanent molars, all teeth were isolated and cleansed with a mixture of water and pumice using a rubber-polishing cup on a low speed hand piece. The teeth were rinsed and dried with an oil-free air syringe, and were etched with the conventional acid etching technique (37 per cent orthophosphoric acid applied for 30 seconds). They were subsequently rinsed thoroughly with water to ensure total removal of etchant and dried according to the manufacturer’s instructions.

A liberal coat of the Moisture-Insensitive Primer was applied to the etched area of the teeth destined for Unite and Transbond MIP using a nylon brush. The brush was dipped in the primer for each tooth to be primed. Air was gently blown on each tooth for 2–5 seconds, aiming the air stream perpendicular to the enamel surface. After this, a thin coat of the conventional primer supplied in conjunction with Unite was applied to the bracket base, followed by the adhesive paste. The bracket was then applied to the enamel surface and adjusted to final position by exerting a pressure to firmly seat it. Excess adhesive surrounding the bracket was gently removed.

To the remaining teeth to be bonded with Assure, the special liquid activator was applied in two coats, left for 10 seconds, lightly dried, and then light-cured for 10 seconds. Subsequently, the adhesive paste was applied to the bracket base using a wooden stick supplied by the manufacturer. The bracket was then positioned on the etched surface and pressed firmly. Excess resin was gently removed, and the adhesive was light-cured for 20 seconds from the incisal edge and then 10 seconds from each additional side, giving a total curing time of 50 seconds per bracket.

Initial wires were fitted 10–15 minutes after bonding completion. For each case, a similar treatment approach (e.g. archwire sequence) was adopted in the context of the straight wire technique. The patients were followed for a period of 9 months. Bond failures were recorded in each patient’s special record, with the time of bond failure identified as the date when bond failure was noticed. A code was assigned to each bonded bracket indicating that it survived the observation period or had failed. The following information was also recorded in a similar way for each bracket:

  1. the adhesive used;
  2. the date of bonding;
  3. the date and the alleged reason of bond failure;
  4. the Adhesive Remnant Index (ARI) score.14Go

All patients received the same instructions and were seen at 3–4-week intervals. They were, however, requested to attend as soon as possible once a bond failure was apparent. They were instructed to brush with a manual toothbrush using a fluoride-containing toothpaste.

Statistical analysis
Bond failure rates during a period of 9 months were estimated for each adhesive system and the corresponding bracket survival curves were plotted using the Kaplan–Meier product-limit estimate. Bracket survival distributions with respect to adhesive material, tooth location (upper/lower, anterior/posterior, right/left side), patient’s gender, and operator, were then compared by means of a log-rank test. Bond failure interface was determined for each bonding agent using the ARI score distribution.


    Results
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
Adhesive
A total of 46 bond failures were registered during the 9 months of the observation period: 16 (7.3 per cent) occurred with Unite and Transbond MIP, while 30 (13.8 per cent) with Assure (Table 1Go). The corresponding bracket survival curves were plotted using the Kaplan– Meier product-limit estimate (Figure 1Go). The log-rank test, revealed that Assure had a higher bond failure rate than Unite and Transbond MIP (P < 0.05).


View this table:
[in this window]
[in a new window]
 
Table 1 Bond failure rates for the orthodontic adhesives
 


View larger version (11K):
[in this window]
[in a new window]
 
Fig. 1 Bracket survival distribution of both orthodontic adhesives plotted against time.

 
Tooth location
We also found there was no difference between the upper and the lower dental arches (Table 2Go), or between the right and the left side (Table 3Go). Premolars, however, exhibited higher bond failure rate than incisors and canines (P < 0.001). This was also true when each bonding agent was examined separately (Table 4Go).


View this table:
[in this window]
[in a new window]
 
Table 2 Bond failure rates: upper vs. lower arch
 

View this table:
[in this window]
[in a new window]
 
Table 3 Bond failure rates: right vs. left side of the dental arch
 

View this table:
[in this window]
[in a new window]
 
Table 4 Bond failure rates: anterior (incisors, canines) v. posterior (premolars) teeth
 
Patient’s gender
No difference was found in the frequency of bond failures with respect to the patient’s gender (Table 5Go).


View this table:
[in this window]
[in a new window]
 
Table 5 Bond failure rates: girls v. boys
 
Investigator
The difference in the failure rates observed between the two operators was found to be non-significant (P > 0.05), thus enhancing the reliability of the reported results (Table 6Go).


View this table:
[in this window]
[in a new window]
 
Table 6 Bond failure rates between the operators
 
Bond failures as a function of time
Half of the total bond failures (49.8 per cent) occurred during the first 2 months of treatment (Figure 2Go).



View larger version (72K):
[in this window]
[in a new window]
 
Fig. 2 Bond failure percentage as a function of time.

 
Bond failure interface
The predominant mode of failure was within the bonding material (cohesive failure) for both adhesives. However, Assure exhibited a higher frequency of ARI score of 3 (all adhesive remaining on the enamel), which indicates a greater tendency towards adhesive failure (Figure 3Go).



View larger version (65K):
[in this window]
[in a new window]
 
Fig. 3 Distribution of ARI scores for each adhesive.

 

    Discussion
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
Study design
In vitro investigation of bond strength plays an important role in evaluating the bonding efficiency of newly introduced orthodontic systems. While it is true that certain aspects of physical and chemical adhesive properties may be clarified by ex vivo approaches, the actual performance of the system can only be evaluated in the environment where it was intended to function.13Go Therefore, the most reliable method to illustrate the clinical efficiency of new bonding materials is the evaluation of clinical bond failure rate using randomized controlled clinical trial methodology.

The bonding systems studied were not water-activated, but moisture-resistant, which means that their manufacturers claim that they can perform even on moisture contaminated enamel. In fact, in a number of previous in vitro studies,9–Go11Go the shear bond strength values obtained using the same orthodontic adhesives under moist conditions were inferior to those obtained under dry conditions. The authors believe that the most probable benefit from using these bonding materials could be minimizing the effects of accidental enamel contamination in areas, where efficient moisture control is challenging, such as second molars, partially erupted (particularly lower) premolars or just exposed impacted teeth. As a consequence, for ethical reasons, but also due to the difficulty in standardizing not only the amount of moisture to use, but also the type (water, saliva, blood),12Go the present clinical study was performed under dry conditions, which is current clinical practice.

Bond failure rate
In this in vivo study the bond failure rate of Unite in conjunction with Transbond MIP was 7.3 per cent. In a parallel study15Go performed by the same authors, in the same clinic and under the same conditions, the bond failure rate of a standard composite resin (System 1+, Ormco, Orange, California, USA) was found to be 5.1 per cent. Bond failure rates below 10 per cent are generally considered as clinically acceptable, although the direct comparison between studies should be interpreted with caution, since there is not yet a standardized protocol for such clinical studies.16Go

Very recently, comparison of the clinical failure rates of brackets bonded using a prototype hydrophilic primer, designed to be insensitive to moisture, with brackets bonded with a conventional primer was reported. It was concluded that the hydrophilic primer—that was also the basis of the presently used primer—could not be recommended for routine clinical use.17Go The other moisture-resistant adhesive in our study, a compomer (Assure), recorded a significantly higher bond failure rate (13.8 per cent). Compomers, which are polyacid-modified resins, have been developed in an attempt to bring the positive properties of glass ionomer cements to light-cured composite resins. Although they behave primarily like resins, it is postulated that light curing initiates a delayed acid-base reaction, that may release fluoride from the aluminosilicate glass upon water absorption, but their physical properties are inferior to those of the composite resins.18Go The shear bond strength of Assure was found significantly lower (though still clinically acceptable) in comparison with a light-cured composite resin in two recently published in vitro investigations.9,Go11Go

We also found that there was no difference in bond failure rate between the upper and lower dental arch. This is in agreement with previous clinical studies,19–Go24Go although in some others more failures were reported in the lower arch.2–Go4,Go25–Go27Go This could be attributed to the difficulty of moisture control in the lower arch, as well as to the occlusal forces having more pronounced effect on the lower teeth. In another study, more failures were found in the upper arch leading to the conclusion that occlusal forces do not play a major role in bond failure rate.28Go

The failure rate of brackets bonded to the posterior teeth (first and second premolars) was found to be three times higher than the brackets bonded to the anterior teeth (incisors and canines), confirming the findings of previous studies.2–Go4,Go20Go21,Go25,Go27,Go29–Go32Go The high incidence of bracket failures in the posterior parts of the dental arch could be associated to a number of factors, such as the poor moisture control,2,Go27,Go31Go the partial eruption of second premolars,4,Go33Go the heavier occlusal forces exerted on the posterior teeth during mastication,21,Go34Go and the larger amounts of aprismatic enamel on premolars affecting the quality of micromechanical bond.25,Go35Go However, in two recent clinical studies no statistically significant difference was found between the six anterior and the four posterior (first and second premolars) teeth.18,Go22Go

The bond failure rate with respect to the side of the dental arch has not received much attention in previously published clinical studies. The few reports available are contradictory since they found more bond failures in the left21Go or the right side of the dental arch.29Go There are several possible factors in determining the difference of bond failure rate between the two sides: the clinicians being right-handed could make access, bracket placement, and moisture control easier on the right side, the habitual side during mastication, and the difference in pressure exerted during toothbrushing.36Go In the present study, we found no differences in bond failure rates between the right and the left side, although both clinicians and the majority of patients were right-handed (Table 3Go).

The gender of patients did not influence the bond failure rates obtained in the present study (Table 5Go), confirming previous clinical reports.15,Go29,Go31,Go37Go However, the authors of another study concluded that boys exhibit more failures, the girls, presumably, taking better care of the appliance.22Go There are reports of statistically significant differences between the operators in terms of bracket survival time.25,Go37,Go38Go This was not the case in the present study, thus enhancing the reliability of the reported results (Table 6Go). This could be attributed to the operators having the same clinical experience, as well as to the study being performed in the same postgraduate clinic, using the same treatment approach and appliances.

The predominant mode of failure was within the bonding material (cohesive) for both adhesive systems under study, since the 93.7 and 76.1 per cent of bond failures with Unite and Transbond MIP, and Assure, respectively, were characterized by ARI scores of 1 and 2 (Figure 3Go). However, Assure exhibited a significant percentage (15.3 per cent) of failures at the adhesive-bracket interface (adhesive), confirming the findings of a previous in vitro study where the relevant number was 17.5 per cent.11Go This could indicate a possible weakness at the adhesive-bracket base interface.


    Conclusion
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
The results of this study suggest the following:

  1. Unite and Transbond MIP could be a useful alternative to conventional orthodontic adhesives.
  2. Assure, a polyacid-modified composite resin with fluoride-releasing capacity, was associated with a higher bond failure rate, which could be related to the observed tendency for more adhesive failures at the adhesive-bracket interface, indicating some possible weakness at the interface adhesive-bracket.


    References
 Top
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 Conclusion
 References
 
1 Bishara SE, Khowassah MA, Oesteerle LJ. Effect of humidity and temperature changes on orthodontic bonding adhesive systems. J Dent Res 1975; 54: 751–8.[Abstract/Free Full Text]

2 Zachrisson BU. A post-treatment evaluation of direct bonding in orthodontics. Am J Orthod 1977; 71: 173–89.[CrossRef][Medline]

3 Newman GV. A post-treatment survey of direct bonding of metal brackets. Am J Orthod 1978; 74: 197–206.[CrossRef][Medline]

4 Mizrahi E. Success and failure of banding and bonding. A clinical study. Angle Orthod 1982; 52: 113–17.[Medline]

5 Trimpeneers LM, Dermaut LR. A clinical trial comparing the failure rates of two orthodontic bonding systems. Am J Orthod Dentofac Orthop 1996; 110: 547–50.[CrossRef][Medline]

6 Grandhi RK, Combe EC, Speidel TM. Shear bond strength of stainless steel orthodontic brackets with a moisture-insensitive primer. Am J Orthod Dentofac Orthop 2001; 119: 251–5.[CrossRef][Medline]

7 Ewoldsen N, Demke RS. A review of orthodontic cements and adhesives. Am J Orthod Dentofac Orthop 2001; 120: 45–8.[CrossRef][Medline]

8 Hobson RS, Ledvinka J, Meechan JG. The effect of moisture and blood contamination on bond strength of a new orthodontic bonding material. Am J Orthod Dentofac Orthop 2001; 120: 54–7.[CrossRef][Medline]

9 Webster MJ, Nanda RS, Duncanson MG, Khajotia SS, Sinha PK. The effect of saliva on shear bond strengths of hydrophilic bonding systems. Am J Orthod Dentofac Orthop 2001; 119: 54–8.[CrossRef][Medline]

10 Eliades T, Katsavrias E, Eliades G. Moisture-insensitive adhesives: reactivity with water and bond strength to wet and saliva-contaminated enamel. Eur J Orthod 2002; 24: 35–42.[Abstract/Free Full Text]

11 Rix D, Foley TF, Mamandras A. Comparison of bond strength of three adhesives: composite resin, hybrid GIC, and glass-filled GIC. Am J Orthod Dentofac Orthop 2001; 119: 36–42.[CrossRef][Medline]

12 Littlewood SJ, Mitchell L, Greenwood DC, Bubb NL, Wood DJ. Investigation of a hydrophilic primer for orthodontic bonding: an in vitro study. J Orthod 2000; 27: 181–6.[Abstract/Free Full Text]

13 Eliades T, Brantley WA. The inappropriateness of conventional orthodontic bond strength assessment protocols. Eur J Orthod 2000; 22: 13–23.[Abstract/Free Full Text]

14 Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. Am J Orthod 1984; 85: 333–40.[CrossRef][Medline]

15 Karamouzos A, Mavropoulos A, Athanasiou AE, Kolokithas G. In vivo evaluation of a moisture-active orthodontic adhesive: a comparative clinical trial. Orthod Craniofac Res 2002; 5: 170–8.[CrossRef][Medline]

16 Brantley WA, Eliades T. Orthodontic Materials: scientific and clinical aspects. Stuttgart: Thieme, 2001.

17 Littlewood SJ, Mitchell L, Greenwood DC. A randomized controlled trial to investigate brackets bonded with a hydrophilic primer. J Orthod 2001; 28: 301–5.[Abstract/Free Full Text]

18 Verbeeck RMH, De Maeyer EAP, Marks LAM, De Moor RJG, De Witte AMJC, Trimpeneers LM. Fluoride release process of (resin-modified) glass-ionomer cements versus (polyacid-modified) composite resins. Biomaterials 1998; 19: 509–19.[CrossRef][Medline]

19 Cacciafesta V, Bosch C, Melsen B. Clinical comparison between a resin-reinforced self-cured glass ionomer cement and a composite resin for direct bonding of orthodontic brackets. Part I: Wetting with water. Clin Orthod Res 1998; 1: 29–36.[Medline]

20 O’Brien KD, Read MJ, Sandison RJ, Roberts CT. A visible light-activated direct-bonding material: an in vivo comparative study. Am J Orthod Dentofac Orthop 1989; 95: 348–51.[CrossRef][Medline]

21 Sunna S, Rock WP. Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial. Br J Orthod 1998; 25: 283–7.[Abstract]

22 Shammaa I, Ngan P, Kim H, Kao E, Gladwin M, Gunel E, Brown C. Comparison of bracket debonding force between two conventional resin adhesives and a resin-reinforced glass ionomer cement: an in vitro and in vivo study. Angle Orthod 1999; 69: 463–9.[Medline]

23 Cacciafesta V, Bosch C, Melsen B. Clinical comparison between a resin-reinforced self-cured glass ionomer cement and a composite resin for direct bonding of orthodontic brackets. Part 2: bonding on dry enamel and on enamel soaked with saliva. Clin Orthod Res 1999; 2: 186–93.[Medline]

24 Chung CH, Piatti A. Clinical comparison of the bond failure rates between fluoride-releasing and non-fluoride-releasing composite resins. J Clin Orthod 2000; 34: 409–12.[Medline]

25 Lovius BBJ, Pender N, Hewage S, O’Dowling I, Tomkins A. A clinical trial of a light activated material over an 18-month period. Br J Orthod 1987; 14: 11–20.[Abstract]

26 Wiltshire WA. Shear bond strength of a glass ionomer for direct bonding in orthodontics. Am J Orthod Dentofac Orthop 1994; 106: 127–30.[Medline]

27 Trimpeneers LM, Dermaut LR. A clinical trial comparing the failure rates of two orthodontic bonding systems. Am J Orthod Dentofac Orthop 1996; 110: 547–50.

28 Carstensen W. Clinical results after direct bonding of brackets using shorter etching times. Am J Orthod 1986; 89: 70–2.[CrossRef][Medline]

29 Kinch AP, Taylor H, Warltier R, Oliver RG, Newcombe RG. A clinical trial comparing the failure rates of directly bonded brackets using etch times of 15 or 60 seconds. Am J Orthod Dentofac Orthop 1988; 94: 476–83.[CrossRef][Medline]

30 Read MJ, O’Brien KD. A clinical trial of an indirect bonding technique with a visible light-cured adhesive. Am J Orthod Dentofac Orthop 1990; 98: 259–62.[Medline]

31 Millett DT, Hallgren A, Cattanach D, McFadzean R, Pattison J, Robertson M, Love J. A 5-year clinical review of bond failure with a light-cured resin adhesive. Angle Orthod 1998; 68: 351–6.[Medline]

32 Armas Galindo HR, Sadowsky PL, Vlachos C, Jacobson A, Wallace D. An in vivo comparison between a visible light-cured bonding system and a chemically cured bonding system. Am J Orthod Dentofac Orthop 1998; 113: 271–5.[CrossRef][Medline]

33 Underwood ML, Rawls HR, Zimmerman BF. Clinical evaluation of a fluoride-exchanging resin as an orthodontic adhesive. Am J Orthod Dentofac Orthop 1989; 96: 93–9.[CrossRef][Medline]

34 Gorelick L, Geiger AM, Gwinnett AJ. Implications of the failure rates of bonded brackets and eyelets: a clinical study. Am J Orthod 1984; 86: 403–6.[CrossRef][Medline]

35 Whittaker DK. Structural variations in the surface zone of human tooth enamel observed by scanning electron microscopy. Arch Oral Biol 1982; 27: 383–92.[CrossRef][Medline]

36 White L. Toothbrush pressures of orthodontic patients. Am J Orthod 1983; 83: 109–13.[CrossRef][Medline]

37 Hitmi L, Muller C, Mujajic M, Attal JP. An 18-month clinical study of bond failures with resin-modified glass ionomer cement in orthodontic practice. Am J Orthod Dentofac Orthop 2001; 120: 406–15.[CrossRef][Medline]

38 Millet DT, Gordon PH. A 5-year clinical review of bond failure with a no-mix adhesive (Right on). Eur J Orthod 1994; 16: 203–11.[Abstract/Free Full Text]

Received April 9, 2002; accepted November 5, 2002




This article has been cited by other articles:


Home page
Eur J OrthodHome page
S. Elekdag-Turk, D. Isci, T. Turk, and F. Cakmak
Six-month bracket failure rate evaluation of a self-etching primer
Eur J Orthod, April 1, 2008; 30(2): 211 - 216.
[Abstract] [Full Text] [PDF]


Home page
Eur J OrthodHome page
P. Murfitt, A. Quick, M. Swain, and G. Herbison
A randomised clinical trial to investigate bond failure rates using a self-etching primer
Eur J Orthod, October 1, 2006; 28(5): 444 - 449.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mavropoulos, A.
Right arrow Articles by Athanasiou, A. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mavropoulos, A.
Right arrow Articles by Athanasiou, A. E.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS