J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 32, No. 4, 244-246, December 2005 doi:10.1179/146531205225021204
© 2005 British Orthodontic Society

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parkin, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parkin, N.

Clinical Section

Clinical pearl: Clinical tips with System-R

N. Parkin

Charles Clifford Dental Hospital, Sheffield and Barnsley District General Hospital, UK

Address for correspondence: N. Parkin, Department of Orthodontics, Charles Clifford Dental Hospital, Wellesley Road, Sheffield S10 1SZ, UK., Email: nicolaparkin{at}hotmail.com

Received 26 March 2005; accepted 6 June 2005


    Abstract
 Top
 Abstract
 Introduction
 Clinical tips
 Summary
 
The article describes the versatility and ease of use of a relatively new bracket system manufactured by GAC called System-R. This system consists of two bracket types; standard width and reduced width, both of which have an active self-ligating clip. The reduced friction offered by this system allows different mechanics to be employed. Security of ligation and absence of decaying force values allows longer treatment intervals. Fast and reliable opening and closing of the clips means reduced chairside time. Difficulties experienced personally by these brackets are highlighted and some troubleshooting tips are included.

Key words: System-R, self-ligation, active clip, friction


    Introduction
 Top
 Abstract
 Introduction
 Clinical tips
 Summary
 
‘System-R’ (GAC), formerly known as ‘In-Ovation’, is the world’s only self-ligating system that combines a twin bracket with an active clip. The standard sized bracket (Figure 1Go) became available in 1999 and a reduced diameter bracket for anterior teeth was introduced in 2001.



View larger version (105K):
[in this window]
[in a new window]
 
Figure 1 Standard In-Ovation bracket with an additional horizontal slot

 
In the past, many frustrations experienced with self-ligating brackets have been due to failure of the locking mechanism. System-R appears to have resolved this problem and failure of the clip has seldom been reported. If the clip does break, the bracket may be used as a conventional bracket owing to its four tie wings (Figure 2Go).



View larger version (85K):
[in this window]
[in a new window]
 
Figure 2 Clip failure

 

    Clinical tips
 Top
 Abstract
 Introduction
 Clinical tips
 Summary
 
Open and closing
For opening the clip, the ‘Beaver’ tool manufactured by GAC is my preference. The instrument is held at 45° to the long axis of the tooth and gentle pressure is exerted to open the clip (Figure 3Go). It is helpful to start from the left and work round to the right hand side to prevent accidentally closing an already opened clip.



View larger version (71K):
[in this window]
[in a new window]
 
Figure 3 Opening the clip

 
Closing the bracket takes less than 1 second and is achieved by light finger pressure. An audible ‘click’ occurs when the clip is fully closed. The simplicity of opening and closing the clip allows faster archwire changes and requires less chair-side assistance.

Ectopic and severely displaced teeth
The Standard bracket has an additional horizontal slot (Figure 1Go). This slot may be utilized when aligning displaced or ectopic teeth. Figure 4Go illustrates a modification of the ‘piggy-back’ technique. The base archwire is a 0.018-inch round stainless steel archwire; a light 0.014-inch Sentalloy archwire is threaded through a link of the gold chain and through the horizontal slot of the adjacent brackets. It is simpler than the conventional ‘piggy back’ technique because the base archwire may be left in situ when reactivating the gold chain.



View larger version (65K):
[in this window]
[in a new window]
 
Figure 4 Utilization of the horizontal slot

 
Don’t engage second molars during an initial alignment
This system is passive and very low in friction in the initial alignment stages and teeth move very quickly. If second molars are incorporated into the appliance at this stage, it is likely that following alignment, excess archwire will protrude out of the distal aspect of the tube. This will not only increase the risk of soft tissue injury, but in contacting soft tissues may also inhibit anterior alignment and force anterior teeth labially.

During the later stages of treatment, the clip interacts with the archwire and pushes it against the base of the slot. This means that the lingual aspect of the wire contacts the bracket base allowing torque values to be expressed. Figure 5Go illustrates how the clip behaves according to the diameter of the archwire. The clip interacts with the archwire as the diameter exceeds 0.019-inch round or 0.018 x 025-inch rectangular wire.



View larger version (101K):
[in this window]
[in a new window]
 
Figure 5 Wire analysis with a 0.22-inch slot

 
Mesial-distal movement of teeth on lighter archwires
Owing to the low friction in the early stages of treatment, light forces can be applied for mesial-distal movement of teeth on light archwires. Figure 6Go shows NiTi pushcoil with 0.014-inch Sentalloy archwire. There is approximately 2 mm of activation applied to the coil spring. It is an excellent way of expanding arches that are contracted anteriorly.



View larger version (87K):
[in this window]
[in a new window]
 
Figure 6 Creation of space for lateral incisors with a 0.014-inch Sentalloy

 
Bonding
It is essential to remove all excess cement when bonding brackets—any cement left around the clip mechanism may prevent its correct functioning. Consider using light-cured cement or an easily visible colour changing cement.

Prevention of archwire sliding
This is more apparent in low friction systems. My favoured method is to use composite cement on a non-active part of the archwire (Figure 7Go). Acid etching the wire may achieve more micromechanical retention.



View larger version (80K):
[in this window]
[in a new window]
 
Figure 7 Composite to archwire to prevent sliding

 
Other methods that may be employed are:

Inability to seat the archwire
In my experience, the reason for not being able to seat a rectangular wire is either due to the clip not being fully open or presence of debris in the slot.

Calculus
Don’t use this system if patients have a calculus-forming tendency. It is impossible to open the brackets if calculus forms on the clip and removal of adhered calculus risks bracket debond.


    Summary
 Top
 Abstract
 Introduction
 Clinical tips
 Summary
 
I prefer to use a standard sized twin bracket with an active clip as this combines fast and reliable ligation, low friction in the early stages and precise control in the later stages without compromising the quality of the final result. Security of ligation and absence of decaying forces allows for longer treatment intervals and this, combined with reduced chair-side assistance and time, allows savings to be made in clinical time.


    Acknowledgments
 
Thanks go to Russell Samuels & Frances Mackay for encouraging me to use self-ligating brackets when I commenced my FTTA post in May 2001.




This article has been cited by other articles:


Home page
Eur J OrthodHome page
G. Shen, R.-J. Chen, Z. Hu, and Y.-F. Qian
The effects of a newly designed twin-slot bracket on severely malpositioned teeth--a typodont experimental study
Eur J Orthod, August 1, 2008; 30(4): 401 - 406.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parkin, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parkin, N.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS