|
|
||||||||
Scientific Section |
Department of Child Dental Health, Bristol Dental Hospital, Bristol, UK
Department of Dental Biomaterials Science, Guys Hospital, London, UK
Address for correspondence: Dr A. J. Ireland, Department of Child Dental Health, Bristol Dental Hospital, Lower Maudlin Street, Bristol BS1 2LY, UK Email: tony.ireland{at}tiscali.co.uk
Received 9 February 2005; accepted 22 November 2005
| Abstract |
|---|
|
|
|---|
Design: Prospective randomized, controlled clinical trial.
Setting: Orthodontic Department, Bristol Dental School.
Material and methods: Twenty consecutive patients undergoing upper and lower fixed orthodontic treatment entered this cross-mouth control study. Diagonally opposite quadrants were randomly allocated to either the self-etching primer group or the conventional etching group. A total of 339 teeth were bonded with Ideal 1 light-cured adhesive. Bond failures and locus of bond failure were then recorded at 1, 6 and 12 months.
Results: Significantly more bond failures occurred at each of the 3 time intervals, 1, 6 and 12 months, where the enamel was pretreated with the Ideal I self-etching primer, than when the enamel was treated with the conventional etchant, 37% o-phosphoric acid. With the latter the cumulative bond failure rates were 3.0, 5.3 and 14.8%, respectively. With the self-etching primer the cumulative failure rates were 29.4, 56.5 and 72.4%.
Conclusion: The study found that enamel pre-treatment with the Ideal 1 self-etching primer system prior to orthodontic bonding results in an unacceptably high bond failure rate when compared with conventional enamel acid etching.
Key words: Bonding, composite, self-etching primer
| Introduction |
|---|
|
|
|---|
Many researchers have conducted in vitro studies to investigate bond strengths of self-etching primers. Initially, products that were designed for restorative use were tested for possible orthodontic use. However, even between similarly designed studies and sometimes involving the same authors, there appeared to be no consensus view concerning the observed shear bond strength and, therefore, usefulness in orthodontic bonding.4
7
In addition, following concerns about enamel fractures at debond, the manufacturers of the restorative self-etching primer Prompt-L-Pop (3M ESPE) advised against using this product for orthodontic bonding. This product was subsequently modified for orthodontic bonding and is marketed as Transbond PlusTM self-etching primer (3M/Unitek, Dental Products Division, Monrovia, CA, USA). This self-etching primer, like most of the self-etching primers on sale, is a 2-component system that requires mixing prior to use. In vitro experiments using this and other self-etching primers have yielded encouraging results, suggesting that their bond strength is comparable if not higher than that observed following the use of a conventional 37% orthophosphoric acid etch.8
11
Although there are many laboratory studies indicating that brackets can be successfully bonded with self-etching primers, there are few published clinical studies. Prospective clinical trials by Asgari et al.12
and Ireland et al.13
evaluated the bond failure rates using Transbond PlusTM self-etching primer over a 6-month period. Asgari et al.12
concluded that bracket retention using this self-etching primer was superior to that seen following traditional acid etching, whereas Ireland et al.13
reported a bond failure rate of 10.9% following use of the self etching primer, compared with a failure rate of only 4.95% for the control of conventional acid etching.
In an attempt to further simplify the bonding process a 1-component no-mix self-etching primer has been developed where no pre-mixing is required prior to its use. This single component self-etching primer is marketed as part of a complete kit of etchant and adhesive by GAC International, and is known as the Ideal 1 adhesive system (GAC International Inc., Bohemia, NY, USA). The Ideal 1 adhesive within the kit is a conventional filled diacrylate composite resin. To date, no in vivo investigations have been published assessing the clinical performance of this single component self-etching primer system. However, an in vitro study comparing the shear bond strength of the Ideal 1 system with a 2-component self-etching primer system found that both systems produced similar bond strengths.14
The results of a further in vitro study15
performed by the authors of the present in vivo investigation also observed that the force to debond following the use of the Ideal 1 self-etching primer was comparable with that of the conventional etch and rinse control. However, as always, caution should be exercised when extrapolating the results of in vitro studies to the clinical situation.
Therefore, the aim of this study was to investigate the in vivo bond failure rates of the single component orthodontic self-etching primer system, Ideal 1 (GAC Orthodontic Products) and to compare it with the conventional acid etching, rinsing and drying regimen. In both cases, the brackets used were stainless steel orthodontic brackets and the adhesive was Ideal 1 filled diacrylate adhesive (GAC Orthodontic Products).
The following null hypotheses were tested:
| Material and methods |
|---|
|
|
|---|
Patients were treated by 1 operator (KH) at the University of Bristol Dental School and acted as their own controls, the split mouth technique being used. The bonding protocol for each patient followed a contralateral pattern to eliminate operator bias. One quadrant was randomly selected to receive the self-etching primer and adhesive system (Ideal 1GAC International), together with the contralateral quadrant in the opposing arch. The teeth in the other 2 quadrants were treated with 37% orthophosphoric acid etchant and brackets bonded with the same Ideal 1 adhesive. Patients were not informed as to which were the experimental and control quadrants, and randomization was achieved by using random numbers from a random number table and a system of sealed envelopes.
All teeth in both the experimental and control quadrants were pumiced for 510 seconds per tooth with pumice in water slurry, using a rubber cup and a slow speed hand piece. The teeth were then rinsed with water, dried with oil-free compressed air and isolated with retractors. Each quadrant was bonded and cured individually, beginning with the experimental quadrants. In these quadrants the operator applied the self-etching primer to the surface of each tooth by rubbing the primer gently on the enamel surface using the microbrush supplied, and for 20 seconds per tooth in accordance with the manufacturers instructions. A gentle blast of air was then applied to each tooth in that quadrant, for 5 seconds per tooth in an occlusal direction to thin the material. Ideal 1 adhesive was then applied to the bracket base (Omni 0.022-inch meshed based stainless steel brackets, GAC International Inc., Bohemia, NY, USA), the bracket was placed firmly on the tooth using a Mitchells trimmer and the excess adhesive removed from around the periphery using a probe. The adhesive was then light cured, from posterior to the anterior, for 20 seconds per tooth (10 seconds per interspace) using a halogen-curing lamp (Ortholux, 3M Unitek). The lamp was checked prior to use on each patient using the inbuilt light meter.
The control quadrants were etched with 37% orthophosphoric acid for 15 seconds each, rinsed with copious amounts of water and the enamel was then air dried until frosty white in appearance. Once again, Ideal 1 adhesive was applied to the bracket base (Omni 0.022-inch, GAC International Inc., Bohemia, NY, USA), the bracket placed firmly on the tooth, and the excess removed and light curing was performed as for the experimental quadrants. However, in order to ensure the previously bonded brackets were not exposed to further light during curing of the control quadrants, a sheet of rubber dam was placed carefully over the previously bonded brackets in the adjacent and opposing quadrants. Once the brackets had been bonded to the teeth, elastomeric separators were placed at the first molar teeth.
One week after bond placement and separation the patients returned for band and archwire placement. 0.010-inch stainless steel lacebacks were placed in all 4 quadrants and 0.012-inch superelastic nickel titanium archwires were then placed and tied-in with elastomeric modules. At subsequent appointments, the archwire sequence for all patients was 0.016-inch superelastic nickel titanium followed by the archwires that were deemed to be appropriate for each individual case. The lacebacks remained in place and were gently retightened to remove any slack at each visit, although they were still passive.
Any brackets that did fail during treatment were rebonded, but using conventional acid etching of the enamel and these teeth were subsequently excluded from the trial. In addition, brackets that were electively debonded for repositioning during treatment to improve bond position were also excluded from the study and any subsequent data analysis. Any adhesive remaining on the enamel surface at bond failure was assessed and scored according to the Adhesive Remnant Index (ARI) as follows:18
Data on bond failure were collected at 1 and 6 months and 1 year after placement.
| Results |
|---|
|
|
|---|
|
= 0.05. The distribution of failure as a function of treatment, namely Ideal 1 self-etching primer/Ideal 1 adhesive or conventional etching/Ideal 1 adhesive, with time is shown in Table 1
|
|
|
| Discussion |
|---|
|
|
|---|
Although a cross-mouth controlled trial has limitations with respect to independence of the samples, i.e. individual teeth, this model does have the advantage of providing a self-control. The effect of the treatments in this case were largely confined to each of the defined quadrants of the mouth. In addition, the numbers of variables were carefully controlled in an attempt to compare only the enamel pre-treatments, Ideal 1 self-etching primer and the conventional acid etch regimen. This includes the use of only 1 operator. Previously reported trials involving different self-etching primers have used multiple operators increasing the chance of experimental bias. Although the operator was at the very beginning of her postgraduate training in orthodontics, the observed bond failure rates were actually lower for the conventional acid etch group, when compared with the previous reports of bond failure rates of up to 19.5% for operators at the equivalent stage of training.19
A large number of in vitro studies investigating the bond strengths of self-etching primers have produced encouraging results that are comparable with those seen following conventional etching.4
9
However, few studies have investigated the clinical efficiency of self-etching primers for orthodontic bonding and none to date have investigated the use of a single component self-etching primer in the clinical situation. This study was designed to assess the clinical performance of such a product over a 12 month period. However, the results were surprising and very disappointing, given the encouraging results displayed by previous in vitro studies using the same self-etching primer.14
,15
In retrospect, it would also be appropriate in future studies to define in advance what failure rate is unacceptable so that clear criteria exist that specify when recruitment should be terminated (rapidly if necessary).
Analysis of the ARI scores using the KruskalWallis one-way analysis of variance (Figure 2
) showed that the locus of bond failure was significantly different (p = 0.03) between the control conventional etch group and the experimental Ideal 1 self-etching primer group. However, in both groups the mode of failure was principally adhesive at the enamel/resin interface, although more resin remained on the enamel surface in the conventional acid etch group. This tendency for the locus of bond failure to predominate at the enamel adhesive interface when using self-etching primers is in agreement with laboratory studies into their use.4
,6
,10
,21
,22
However, locus of bond failure has not previously been reported in a clinical trial of self-etching primers.
The results of this randomized clinical trial necessitate that the null hypotheses of no difference between the 2 enamel pre-treatment regimens should be rejected. The reason for the poor clinical performance of this single component self-etching primer in comparison with other clinical trials where Transbond PlusTM SEP was tested is unclear. However, the locus of bond failure being predominately at the enamel-adhesive interface may be indicative of a less than optimal enamel adhesive bond.
When deciding on which bonding system to use, ease of application and reduction in application time can only confer a true advantage if a reliable bond to enamel is also achieved. With a cumulative bond failure rate over 12 months as high as 72.4%, the Ideal 1 self-etching primer obviously does not meet the latter requirement. Much of the current work on self-etching primers has been in vitro in nature and, although laboratory tests are an important stepping stone in the development of a product, they can never truly replicate the oral environment and, as such, act as a definitive test of clinical effectiveness. The conflicting results of this clinical trial and the previously conducted in vitro studies,14
,15
using the same materials, are an example of this problem.
Therefore, despite previously encouraging laboratory findings, based on the results of this clinical trial the authors cannot recommend Ideal 1 self-etching primer system for clinical use, due to the unacceptably high level of in-service bond failures.
| Conclusions |
|---|
|
|
|---|
| Authors and contributors |
|---|
|
|
|---|
Dr A. J. Ireland is the guarantor and, as such, accepts full responsibility for the conduct of the study, has access to the data and controlled the decision to publish.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
2 Wang WN, Lu TC. Bond strengths with various etching times on young permanent teeth. Am J Orthod Dentofacial Orthop 1991; 100: 729.[Medline]
3 Gange P. Present state of bonding. J Clin Orthod 1995; 7: 42936.
4 Bishara SE, Gordon VV, VonWald L, Olson ME. Effect of an acidic primer on shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 1998; 114: 2437.[CrossRef][Medline]
5 Bishara SE, Ajlouni R, Laffoon JF, Warren JJ. Effect of a fluoride-releasing self etch acidic primer on the shear bond strength of orthodontic brackets. Angle Orthod 2002; 72: 199202.[Medline]
6 Korbmacher H, Klocke A, Huck L, Kahl-Nieke B. Enamel conditioning for orthodontic bonding with a single-step bonding agent. J Orofac Orthop 2002; 63: 46371.[CrossRef][Medline]
7 Aljubouri YD, Millett DT, Gilmour WH. Laboratory evaluation of a self etching primer for orthodontic bonding. Eur J Orthod 2003; 25: 41115.
8 Arnold RW, Combe EC, Warford JH. Bonding of stainless steel brackets to enamel with a new self-etching primer. Am J Orthod Dentofacial Orthop 2002; 122: 2746.[CrossRef][Medline]
9 Buyukilmaz T, Usumez S, Karaman AI. Effect of self-etching primers on bond strengthare they reliable? Angle Orthod 2003; 73: 6470.[Medline]
10 Larmour CJ, Stirrups DR. An ex vivo assessment of a bonding technique using a self-etching primer. J Orthod 2003; 30: 2258.
11 Dorminey JC, Dunn WJ, Taloumis LJ. Shear bond strength of orthodontic brackets bonded with a modified 1-step etchant-and-primer technique. Am J Orthod Dentofacial Orthop 2003; 124: 41013.[CrossRef][Medline]
12 Asgari S, Salas A, English J, Powers J. Clinical evaluation of bond failure rates with a new self-etching primer. J Clin Orthod 2002; 36: 6879.[Medline]
13 Ireland AJ, Knight H, Sherriff M. An in vivo investigation into bond failure rates with a new self-etching primer system. Am J Orthod Dentofacial Orthop 2003; 124: 3236.[CrossRef][Medline]
14 Bishara SE, Oonsombat C, Ajlouni R, Laffoon JF. Comparison of the SBS of 2 self-etch primer/adhesive systems. Am J Orthod Dentofacial Orthop 2004; 125: 34850.[CrossRef][Medline]
15 House K. An investigation into the effectiveness of a single component self-etching primer system for orthodontic bonding. DDS dissertation, University of Bristol, 2005.
16 Altman DG. Practical Statistics for Medical Research. London: Chapman & Hall, 1991.
17 UCLA Department of Statistics: http://calculators.stat.ucla.edu/powercalc/
18 Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pre-treatment. Am J Orthod 1984; 85: 33340.[CrossRef][Medline]
19 Ireland AJ, Sherriff M. The effect of timing of archwire placement on in vivo bond failure. Br J Orthod 1997; 24, 2435.[Abstract]
20 Agresti, A. An Introduction to Categorical Data Analysis. Hoboken NJ: Wiley Interscience, 1996.
21 Yamada R, Hayakawa T, Kasai K. Effect of using self-etching primer for bonding orthodontic brackets. Angle Orthod 2002; 72: 55864.[Medline]
22 Cacciafesta V, Sfondrini MF, De Angelis M, Scribante A, Klersy C. Effect of water and saliva contamination on shear bond strength of brackets bonded with conventional, hydrophilic, and self-etching primers. Am J Orthod Dentofacial Orthop 2003; 123: 63340.[CrossRef][Medline]
This article has been cited by other articles:
![]() |
S. Elekdag-Turk, D. Isci, T. Turk, and F. Cakmak Six-month bracket failure rate evaluation of a self-etching primer Eur J Orthod, April 1, 2008; 30(2): 211 - 216. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. A. Wenger, S. Deacon, and N. W. T. Harradine A randomized control clinical trial investigating orthodontic bond failure rates when using Orthosolo universal bond enhancer compared to a conventional bonding primer J. Orthod., March 1, 2008; 35(1): 27 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Banks and B. Thiruvenkatachari Long-term clinical evaluation of bracket failure with a self-etching primer: a randomized controlled trial J. Orthod., December 1, 2007; 34(4): 243 - 251. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. A. Wenger, N. E. Atack, C. N. Mitchell, and A. J. Ireland Peri-operative second molar tube failure during orthognathic surgery: two case reports J. Orthod., June 1, 2007; 34(2): 75 - 79. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Manning, S. M. Chadwick, D. Plunkett, and T. V. Macfarlane A randomized clinical trial comparing 'one-step' and 'two-step' orthodontic bonding systems J. Orthod., December 1, 2006; 33(4): 276 - 283. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |