|
|
||||||||
Scientific Section |
Rockhampton, Australia
Countess of Chester NHS Trust, Chester, UK
Department of General Practice and Primary Care, Aberdeen, UK
Address for correspondence: Mr S. M. Chadwick, Countess of Chester NHS Trust, Health Park, Liverpool Road, Chester CH2 1UL, UK. Email: Steve.Chadwick{at}coch.nhs.uk
Received 8 August 2005; accepted 28 March 2006
| Abstract |
|---|
|
|
|---|
Design: Single-centre randomized controlled clinical trial. Thirty-four patients were bonded, each being randomly assigned to either the test or control adhesive.
Setting: NHS Hospital Orthodontic Department, Chester, UK.
Subjects: Orthodontic patients requiring fixed appliance treatment.
Main outcome measures: Bond failure.
Main outcome results: Failure rates over the initial 6-month period were 2.0% (TransbondTM) and 1.7% (SEP) with no statistically significant difference between the two groups. Over the duration of the fixed appliance treatment, bond failure rates increased, but remained acceptable at 7.4 % (TB) and 7.0% (SEP), respectively. When operator, patient and tooth characteristics were analysed, only the bracket location was found to be significant. Maxillary brackets were more likely to fail than mandibular brackets (RR 0.47%; 95% CI 0.22, 1.03). The failure rate for brackets in our study was low when compared with previous studies.
Conclusions: Both the acid-etched control and self-etching primer in combination with adhesive pre-coated brackets were successful for clinical bonding. Their combined failure rate was lower than that reported in similar trials.
Key words: Bond failure, brackets, self-etch primer, TransbondTM
| Introduction |
|---|
|
|
|---|
Recent advances have reduced this two-stage etch and prime adhesive system down to a one-stage self-etching system. The manufacturers claim this combined etch-primer system, TransbondTM Plus Self-Etching Primer, can reduce the time required for the bond up of fixed appliances and is able to work effectively in a moist environment. Therefore, isolation of the enamel surface, to prevent salivary contamination, may not be as critical when using SEP. This may further reduce the chair-side time required for the bond up process. If the bond failure rate using a one-stage system (TransbondTM SEP Plus) is similar or better than conventional two-stage systems, and the clinical bond up time is reduced, it would be advantageous to use a one-stage adhesive system in everyday orthodontic practice.
| Aim |
|---|
|
|
|---|
| Subjects and materials |
|---|
|
|
|---|
Sample size calculation
The sample size for each group was estimated based on the number of brackets required as this was the unit of measurement. A sample size of 540 brackets (270 brackets per group) will be sufficient to detect an improvement or reduction in bond failure after 6 months of 10% from an expected 15% based on similar clinical trials of light-cured composite resins, with 80% power and a 5% significance level using a two-sided, continuity corrected chi-squared test.2
At the time of setting up the trial, there were two published clinical trials using similar materials. These were by Littlewood,3
and Sunna and Rock,4
with reported failure rates of 6.8 and 9.4%, respectively. A higher failure rate was conservatively estimated as other larger trials of light-cured composite reported failure rates of 24.35
and 23.8%.6
To produce 270 brackets per group, approximately 32 patients would be required, as the number of teeth per patient would vary due to extractions, missing teeth and other excluded teeth.
Study design
Thirty-five patients (Figure 1
) were consecutively drawn from the treatment waiting list of the Orthodontic Department, Countess of Chester Hospital. All the patients required fixed orthodontic therapy and no effort was made to match the patients for age, sex or malocclusion to ensure a representative range of orthodontic patients. Patients requiring single arch treatments or orthognathic surgery as part of their orthodontic treatment were excluded. Patients were consented (no information was available on consent rate) and randomly allocated (using random number tables, controlled with permuted blocks to ensure equal numbers of patients in each group after every sixth subject) to either a conventional (two-stage) adhesive group (Transbond TB) or alternatively to the (one-stage) self-etching primer adhesive group (SEP).
|
|
SEP group:
For both groups pre-coated orthodontic brackets (3M Unitek MBT appliance, 3M Unitek Dental Products Division, 2724 South Peck Road, Monrovia, CA 91016, USA) were used. All brackets were light-cured for 30 seconds (XL 3000 light unit, 3M Unitek) and a 0.016-inch Nitinol (3M Unitek Dental Products Division, 2724 South Peck Road, Monrovia, CA 91016, USA) heat-activated arch wire was engaged fully into all of the brackets. Any bond failure was recorded on a data collection sheet on the day the patient attended with the breakage.
The first bond failure for each tooth was recorded by date and tooth number. A failure was regarded as an all or none occurrence, and subsequent failures of bonding for that same tooth were noted, but not included in the failure rate. Failed brackets were replaced using the same adhesive and bonding technique.
Statistical analysis
Statistical data analysis was conducted on both patient and tooth level. Such an approach is useful for comparison with previous studies in reviews.7
Analysis of bond failures on a patient level was done using the MannWhitney test. Where the tooth was the unit of analysis, it was essential to take into account the clustering that occurs within a patient. This was necessary to prevent an individual with a high number of failures from having too great an influence on the results. First, several possible models (exponential, Weibull, lognormal, log-logistic and gamma) were compared (Stata Statistical Software, Version 6.0, Stata Corporation, College Station, Texas, USA) using Akaike information criterion (AIC).8
While the coefficient estimates were very similar between models, the best model was exponential. Such a model assumes that the survival time distribution is exponential, and dependent on the values of a set of independent variables (zi), e.g. stronger bonds tend to last longer. Exponential distribution can be expressed as: S(z) = exp(a + b1*z1 + b2*z2 + ... + bm*zm), where S(z) denotes the survival times, a is a constant, and the bis are the regression parameters. Backward stepwise selection was then applied (based on the likelihood-ratio statistic). In order to evaluate the fit of the model, Cox-Snell residuals were calculated and plotted against estimate of the cumulative hazard function. The plot showed that the model fitted the data well.
| Results |
|---|
|
|
|---|
Results for tooth level
A total of 597 brackets were bonded, of which 43 (7.2%) failed (Table 2
). There was no statistically significant difference in rate of bond failure between the two bonding systems. Also no statistically significant difference in rate of bond failure was found for operator, age of the patient and whether failures occurred left or right or anterior/posterior (Table 2
, Figure 2
). Lower brackets were however significantly less likely to fail [RR 0.17; 95% CI (0.07, 0.43)]. The rate of failure in females was half that of the males, but this difference was not statistically significant [RR 0.47; 95% CI (0.22, 1.03)]. When stepwise regression was performed, the only predictors of failure were tooth location and gender. A comparison of bracket failure over treatment time intervals is shown in Table 3
.
|
|
|
| Discussion |
|---|
|
|
|---|
Study design
While the study achieved the required sample size, the original sample size calculations did not take into account aggregation of brackets within the participants, modelling using other covariates or multiple testing issues. The use of clusters (individuals in this case) reduces the power of the trial11
and multiple testing increases the chance of false positive results, so an increase in sample size is required. Future RCTs in orthodontics should take these issues into account and increase the required sample size accordingly.
Recent clinical trials comparing bonding systems have used a split-mouth design where one side or contralateral quadrants are bonded using a study adhesive, whilst the alternative side serves as the control adhesive. The advantage of this is that patient factors, such as poor care of the appliances will be accounted for evenly, as the patient acts as their own control. However, it is possible that one bonding agent will affect how the other performs, and that bracket placement will not be true reflection of clinical practice, as the bracket placement technique will be altered during bonding when the changeover between the bonding system occurs. Randomly allocating one material to each patient eliminates this problem.
Pre-coated brackets
Adhesive pre-coated brackets (APC) were used in this study, as this ensures a uniform consistency of adhesive on each bracket, regardless of which technique was used and so eliminates adhesive placement as a variable. Previous studies4
,5
found no difference in bond failure rate between APC brackets and other uncoated brackets, and it would seem reasonable to assume that bond failure rates would be similar if uncoated brackets and Transbond adhesive were used.
Timing
Describing bond failure rate over the whole period of a course of treatment in randomly allocated patients means that any variation due to treatment length is eliminated. If this is not done and a set time period (e.g. 1 year) is used, it may fail to reveal if one materials performance deteriorates over time. In this study failure rates were analysed at 6 and 12 months and at completion of treatment (Table 3
). Previous studies have used 6- and 12-month intervals only. Six-month studies,3
,12
,13
using similar materials, have shown failure rates varying from 1.1 to 6.8%. Aljubouri et al.12
compared the same materials at 6- and 12-month intervals, and found no statistical difference between them. In this study, the failure rate for SEP increased from 1.7% at 6 months to 7.0% at completion of treatment, and for Transbond the bond failure rate increased from 2.0 to 7.4%. This shows that although failure rates increased for both materials over the treatment time, there was no difference between the two materials at each time interval. A recent review of orthodontic bonding studies performed by the Cochrane Oral Health Group7
recommended that bonding studies follow all trial patients to the end of fixed appliance treatment. Our study follows that guideline and the fact that failure rate increased over the total treatment time for both materials supports this recommendation.
Tooth factors
Failure rates were compared between anterior and posterior teeth. The overwhelming conclusion from other studies is that posterior teeth suffer more bracket failure than incisors and canines.4
7
,9
,10
,14
16
A number of possible explanations for this are given difficult clinical access and isolation from moisture in the posterior regions, higher occlusal forces on posterior teeth and more aprismatic enamel on premolars. This study was in contrast to these other studies in that there was a failure rate of 8.4% for anterior and 4.9% for posterior teeth; however, this was not statistically different.
There was a statistical difference in bracket failure rates between maxillary and mandibular teeth. Maxillary brackets (12.4%) were five times more likely to fail than brackets bonded to mandibular teeth (2.3%), [RR 0.17%, 95% CI (0.07,0.43)]. The reasons for this are unclear but it would seem that brackets bonded to maxillary anterior teeth were the most likely to fail. Perhaps habits such as nail biting and pen chewing are significant in accounting for this and may outweigh dietary factors that may predipose to failure of posterior brackets under occlusal load.
Patient factors
Patient factors age and gender were found not to be statistically significant in this study; however, the bond failure rate was higher for boys. Millet et al.17
found bracket survival slightly better in males, while Norevall et al.14
showed bracket survival better in females. Both these results were not statistically significant. Poor patient compliance with dietary instructions and lack of care of the fixed appliances is a likely cause of bracket failure rate above the mean. OBrien et al.9
reported five patients with three bracket failures each and Zachrisson16
found 7% of patients had five or more failures. A similar trend was found in this study with one patient experiencing six bracket failures out of the 22 total recorded failures for Transbond in the entire study. All patients in the hospital department are required to have a plaque score less than 10% before being placed on the waiting list, and all attend sessions with a qualified oral health educator prior to treatment. This may mean that this group of patients are particularly well motivated and compliant in respect of care of their appliances, and this may explain the low overall bracket failure compared with other studies.
Failure rates
At 6 months, the overall bond failure rate for both groups (1.8%) was low compared with other published studies.4
,6
,9
,18
,19
The highest bracket failure rate was reported by Lovius et al.6
at 23.8%. Studies using the pre-coated brackets showed lower failure rates. Littlewood et al.3
studied the failure rate of pre-coated brackets bonded using the same two-step adhesive system as this study. They reported a failure rate of 6.8% after 6 months. Sunna and Rock4
reported a 9.4% failure rate of pre-coated brackets. A more recent in vitro study20
compared the same two adhesive systems used in this study and found in vitro bond strengths were greater for the two-step adhesive (9.8 MPa) than the one-step self-etching system (7.5 MPa). In vitro studies do not truly represent the clinical environment and, as both adhesives performed well clinically in this study, this would suggest that differences in in vitro bond strengths may be clinically insignificant. A recent paper has reported high failure rates using an alternative self-etching primer system. Clearly, manufacturers vary in the quality of these materials.21
There was no statistical difference between the bond failure rates of both adhesive groups and both groups performed well. Using either a two-step acid-etched resin bonding system or a one-step self-etch resin bonding system resulted in low bond failure rates. The one-step system (TransbondTM Plus) is however quicker to use as it does not involve an initial acid etch/wash process. Whether this time difference is critical depends on the relative importance of timing to each individual clinician.
The lack of a washing/drying step and the fact that moisture isolation is claimed to be not so critical, means that the bonding procedure for one-step adhesives may be more comfortable for the patient and anecdotal evidence would support this. The one-step system is certainly simpler to use clinically than the two-step system. Both systems appear to perform equally well and the decision to use a particular adhesive will come down to individual clinical preference. Additional factors, e.g. cost will further influence adhesive choice.
| Conclusion |
|---|
|
|
|---|
| Contributors |
|---|
|
|
|---|
| References |
|---|
|
|
|---|
2 Elashoff JD. nQuery Advisor 5.0, 2002
3 Littlewood SJ, Mitchell L, Greenwood DC. A randomised control trial to investigate brackets bonded with a hydrophilic primer. J Orthod 2001; 28: 30105.
4 Sunna S, Rock WP. Clinical performance of orthodontic brackets and adhesive systems: a randomised clinical trial. Br J Orthod 1998; 25: 28387.[Abstract]
5 Trimpeneers LM, Dermaut LR. A clinical trial comparing the failure of two orthodontic bonding systems. Am J Orthod Dentofacial Orthop 1996; 110: 24750.[CrossRef][Medline]
6 Lovius BB, Pender N, Hewage S, ODowling I, Tomkins A. A clinical trial of a light activated bonding material over an 18 month period. Br J Orthod 1987; 14: 1120.[Abstract]
7 Mandell NA, Millett DT, Mattick CR, Hickman J, Worthington HV, Macfarlane TV. Orthodontic adhesives: a systematic review. J Orthod 2002; 29: 20510.
8 Akaike H. A new look at the statistical model identification. IEEE Transaction and Automatic Control AC-19 1974; 71623.
9 OBrien KD, Read MJF, Sandison RJ, Roberts CT. A visible light-activated direct-bonding material: an in-vivo comparative study. Am J Orthod Dentofacial Orthop 1989; 95 : 34851.[CrossRef][Medline]
10 Armas Galindo HR, Sadowski PL, Vlachos C, Jacobson A, Wallace D. An in-vivo comparison between a visible light-cured bonding system and a chemically cured bonding system. Am J Orthod Dentofacial Orthop 1998; 113: 27175.[CrossRef][Medline]
11 Kerry SM, Bland JM. Sample size in cluster randomisation. BMJ 1998; 316: 549.
12 Aljubouri YD, Millett DT, Gilmour WH. Six and 12 months evaluation of a self-etching primer versus two-stage etch and prime for orthodontic bonding: a randomized clinical trial. Eur J Orthod 2004; 26: 56571.
13 Wong M and Power S. A prospective randomised clinical trial to compare pre-coated and non pre-coated brackets. J Orthod 2003; 30: 15558.
14 Norevall LI, Marcusson A, Persson M. A clinical evaluation of a glass ionomer cement as an orthodontic bonding adhesive compared with an acrylic resin. Eur J Orthod 1996; 18 : 37384.[CrossRef][Medline]
15 Wright AB, Lee RT, Lynch E, Young KA. Clinical and microbiological evaluation of a resin modified glass ionomer cement for orthodontic bonding. Am J Orthod Dentofacial Orthop 1996; 110: 46975.[CrossRef][Medline]
16 Zachrisson BU. A posttreatment evaluation of direct bonding in orthodontics. Am J Orthod 1977; 71: 17389.[CrossRef][Medline]
17 Millet DT, McLuskey LA, McAuley F, Creanor SL, Newell J, Love J. A comparative clinical trial of a compomer and a resin adhesive for orthodontic bonding. Angle Orthod 2000; 70 : 23340.[Medline]
18 Ash S, Hay N. Adhesive pre-coated brackets, a comparative clinical study. Br J Orthod 1996; 23: 32529.[Abstract]
19 Gaworski M, Weinstein M, Borislow AJ, Braitman L. Decalcification and bond failure: a comparison of glass ionomer and a composite resin bonding system in vivo. Am J Orthod Dentofacial Orthop 1999; 116: 51821.[CrossRef][Medline]
20 Grubisa HS, Heo G, Raboud D, Glover KE, Major PW. An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. Am J Orthod Dentofacial Orthop 2004; 126: 21319.[CrossRef][Medline]
21 House K, Ireland AJ, Sherriff M. An investigation into the use of a single component self-etching primer adhesive system for orthodontic bonding: a randomized controlled clinical trial. J Orthod 2006; 33(1): 3844.
This article has been cited by other articles:
![]() |
S. Elekdag-Turk, D. Isci, T. Turk, and F. Cakmak Six-month bracket failure rate evaluation of a self-etching primer Eur J Orthod, April 1, 2008; 30(2): 211 - 216. [Abstract] [Full Text] [PDF] |
||||
![]() |
Commentaries on scientific papers published in this edition J. Orthod., March 1, 2008; 35(1): 25 - 26. [Full Text] [PDF] |
||||
![]() |
N. A. Wenger, S. Deacon, and N. W. T. Harradine A randomized control clinical trial investigating orthodontic bond failure rates when using Orthosolo universal bond enhancer compared to a conventional bonding primer J. Orthod., March 1, 2008; 35(1): 27 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Reis, J. E. d. Santos, A. D. Loguercio, and J. R. de Oliveira Bauer Eighteen-month bracket survival rate: conventional versus self-etch adhesive Eur J Orthod, February 1, 2008; 30(1): 94 - 99. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Luther Award winning papers. So what? J. Orthod., December 1, 2007; 34(4): 209 - 212. [Full Text] [PDF] |
||||
![]() |
P. Banks and B. Thiruvenkatachari Long-term clinical evaluation of bracket failure with a self-etching primer: a randomized controlled trial J. Orthod., December 1, 2007; 34(4): 243 - 251. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Luther With great pleasure: a prize for best scientific paper, and finding out what readers think J. Orthod., September 1, 2007; 34(3): 153 - 153. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |