J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 34, No. 1, 2-5, March 2007 doi:10.1179/146531207225021852
© 2007 British Orthodontic Society

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ross, A. P.
Right arrow Articles by Quick, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ross, A. P.
Right arrow Articles by Quick, A. N.

Clinical Section

Breakages using a unilateral fixed functional appliance: a case report using The ForsusTM Fatigue Resistant Device

Angela P. Ross

School of Dentistry, University of Otago, Dunedin, New Zealand

Benjamin J. Gaffey and Andrew N. Quick

Discipline of Orthodontics, University of Otago, Dunedin, New Zealand

Address for correspondence: Miss Angela Patricia Ross, Discipline of Orthodontics, University of Otago, School of Dentistry, P.O. Box 647, Great King Street, Dunedin, 9054, New Zealand. Email: rosan040{at}student.otago.ac.nz

Received 13 June 2006; accepted 7 November 2006


    Abstract
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
Fixed functional appliances are designed to provide a simple non-compliant solution to orthodontic Class II treatment. Molar correction can be achieved very quickly using these appliances, but the clinician should be wary of unexpected breakages. This case report documents such an occurrence using a unilateral fixed functional appliance.

Key words: Forsus Fatigue Resistant Device, unilateral Class II correction


    Introduction
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
Unilateral Angle Class II malocclusions occur in approximately 16% of the population, with two-thirds of those cases occurring on the right-hand side.1Go Over the past few years, treatment plans involving non-extraction treatment and non-compliance therapies have become increasingly popular.2Go A non-extraction approach often requires distal movement of maxillary molar teeth so as to achieve the Class I molar and canine relationship, and for many years, headgear was used routinely for unilateral distal movement of maxillary molars.3Go This treatment regime not only relied on good patient co-operation, but also had a tendency to generate unwanted lateral forces, leading to a unilateral cross-bite.4Go,5Go

Since the reinvigoration of the Herbst Appliance by Pancherz6Go in the 1970s, many different non-compliant variants have come onto the market.7Go They claim to allow greater freedom of movement of the mandible and allow lateral jaw movements to be carried out with ease. The major drawback with these appliances is the propensity with which fractures can occur, both in the appliance itself and in the support system.


    ForsusTM Fatigue Resistant Device
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
The ForsusTM Fatigue Resistant Device (3M Unitek, Monrovia) is an innovative three-piece telescoping spring for Class II correction. It consists of a universal spring module, an ‘L’ pin and a push rod that is available in five different sizes (Figure 1Go). It is assembled so that the appropriately sized push rod attaches directly to the lower archwire distal to the canine teeth, and the spring to the headgear tube via the ‘L’ pin. Assembly usually takes a few minutes per side.


Figure 1
View larger version (51K):
[in this window]
[in a new window]

 
Figure 1 The ForsusTM Fatigue Resistant Device

 
The Forsus springs require anchorage preparation before they can be placed to minimize unwanted movement. It is necessary to align and level arches prior to insertion of the device with a minimum of 0.016 x 0.022-inch stainless steel (SS) required in a 0.018-inch slot, or a 0.019 x 0.025-inch wire in a 0.022-inch slot. The archwires should be tightly cinched and lower canines tied into the archwire with steel ligatures.

The appliance places a distal force on the upper arch and a mesial force on the lower arch, allowing for Class II correction. Incremental forces can be created by placing 2-mm split crimps onto the push rod, increasing the pressure on the spring.

A literature review was conducted using Medline (PubMed) and no articles were found pertaining to the use of this appliance.


    Case report
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
A 13-year-old female presented with a dental Class II division 2 malocclusion. The overjet was 6.5 mm and the overbite was 50%, with the maxillary midline coincident with the facial midline and the mandibular midline 3 mm to the right of the facial centreline. The upper right central incisor had slipped contact and overlapped the upper left central incisor. The upper right canine and lateral incisor were mesiopalatally rotated, and the upper right posterior teeth had migrated mesially. Consequently, the patient displayed a Class II molar relationship on the right (Figures 2Go and 3Go).


Figure 2
View larger version (32K):
[in this window]
[in a new window]

 
Figure 2 (a–d) A 13-year-old female patient with unilateral dental Class II division 1 malocclusion before treatment. Pre-treatment photographs: extra-oral

 

Figure 3
View larger version (56K):
[in this window]
[in a new window]

 
Figure 3 (a–e) A 13-year-old female patient with unilateral dental Class II division 1 malocclusion before treatment. Pre-treatment photographs: intra-oral

 
The goal of orthodontic treatment was to reduce the overjet and overbite, and correct the molar relationship to Class I on both sides, using a non-extraction approach. It was decided that a unilateral ForsusTM spring would provide the mechanics necessary to achieve our aims.

Fixed pre-adjusted (0.018-inch Wick–Alexander prescription, RMO, Denver, Colorado) appliances were placed with headgear tubes on the upper molar bands. An initial 0.014-inch round nickel titanium archwire was used for levelling and alignment of both arches, with heavily rotated teeth ligated in with 0.010-inch SS ligatures. Two months later, upper and lower 0.014-inch round steel wires were placed with appropriate bite-opening curves.

After 13 weeks, enough levelling and aligning had occurred to place 0.016 x 0.022-inch SS wires in both arches, and these were cinched tightly. A ForsusTM spring was fitted to the right-hand side with a 25-mm push rod, according to the manufacturer’s guidelines. The lower right canine was ligated to avoid elastic ligature breakage and to secure the arch-wire to the bracket.

One month later, 0.0175 x 0.022-inch SS wires were placed in the upper and lower arches and a split crimp was inserted on the push rod. The patient returned 12 days later with the ‘L’ ball pin fractured and the split crimp missing. The patient stated that they had swallowed the crimp. A new pin and split crimp were placed. At the next scheduled appointment, a further split crimp was added to reactivate the appliance.

Five-and-a-half months into treatment (21/2 months after placement of the appliance), the patient returned again with a breakage (Figure 4Go). This time, the pre-welded molar tube had sheared off from the band (3M Unitek, Monrovia, USA). All broken parts were accounted for. Since the full unit Class II molar correction had been achieved in 2 months, a decision was made to remove the ForsusTM spring. Final arch coordination and detailing was completed with the same archwires and light Class II elastics. Treatment was finished at 91/2 months, with all treatment objectives met (Figure 5Go). The lower dental midline was coincident with the upper dental midline as well as with the facial midline.


Figure 4
View larger version (46K):
[in this window]
[in a new window]

 
Figure 4 (a–e) Patient after the ForsusTM spring sheared the pre-welded tube off the upper molar band. The spring and tube were removed from the mouth for safety reasons

 

Figure 5
View larger version (55K):
[in this window]
[in a new window]

 
Figure 5 Patient after treatment. (a–e) Post-treatment photographs: intra-oral. (f) Post-treatment photograph: extra-oral

 

    Discussion
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
While the concept of non-compliant appliances may seem attractive to the practitioner, one must question what non-compliance actually means. Compliant can be defined as ‘ready to yield to the wishes or desires of others’.8Go These appliances remove the need for a patient to comply, but when faced with constant repair and monitoring of breakages, they may instead transfer the compliance to the practitioner.

The case detailed above highlights a potential fault inherent in the unilateral fixed functional appliance. The unilateral spring provided the necessary mechanics to achieve the treatment aims in 91/2 months, well ahead of the estimated 18 months. This time saving came at a price of two breakages and the possibility of inhalation of unsecured components. In this particular instance, the breakage had occurred at an unknown time period prior to attendance at the clinic, with the patient reasonably certain that the object had been swallowed. There were no signs or symptoms of concern, and given the small, smooth nature of the missing object, it was deemed unnecessary to pursue the matter further. This is in keeping with the recommendations of the British Orthodontic Society Advice Sheet 9, ‘Guidelines for the management of inhaled or ingested foreign bodies’.9Go

The breakage incident was reported to the manufacturers, and the remaining portion submitted for analysis. In our department, we have so far placed 17 springs (five bilaterally and seven unilaterally), with the following breakages: eight lost split crimps, one broken ‘L’ pin, and one broken pre-welded molar band.


    Conclusions
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
Breakages are an unfortunate part of orthodontic treatment. Non-compliant appliances attempt to limit one aspect of treatment problems, but can sometimes create other unwanted effects that can be potentially dangerous to the patient. The practitioner should be wary that their treatment plans may not be solving problems, but substituting for them instead.


    References
 Top
 Abstract
 Introduction
 ForsusTM Fatigue Resistant...
 Case report
 Discussion
 Conclusions
 References
 
1 Heikkinen T, Poikela T, Grön M, Alvesalo L. Unilateral Angle II in functional lateralities. Eur J Orthod 2004; 26: 93–98.[Abstract/Free Full Text]

2 Holman JK, Hans MG, Nelson S, Powers MP. An assessment of extraction versus nonextraction orthodontic treatment using the peer assessment rating (PAR) index. Angle Orthod 1998; 68: 527–34.[Medline]

3 Haack DC, Weinstein S. The mechanics of centric and eccentric cervical traction. Am J Orthod Dentofacial Orthop 1958; 44: 236–57.

4 Baldini G. Unilateral headgear: lateral forces as unavoidable side effects. Am J Orthod Dentofacial Orthop 1980; 77: 333–40.

5 Yoshida N, Jost-Brinkmann P, Miethke R, Konig M, Yamada Y. An experimental evaluation of effects and side effects of asymmetric face bows in the light of in vivo measurements of initial tooth movements. Am J Orthod Dentofacial Orthop 1998; 113: 558–66.[CrossRef][Medline]

6 Pancherz H. Treatment of Class II malocclusions by jumping the bite with the Herbst appliance: a cephalometric investigation. Am J Orthod 1979; 76: 423–42.[CrossRef][Medline]

7 Ritto AK. Fixed functional appliances—a classification. Orthodontic CYBERjournal 2001; www.oc-j.com/june01/rittoffa.htm

8 Oxford English Dictionary, 2nd Edn, s.v. ‘compliant’.

9 British Orthodontic Society. Advice Sheet 9: Guidelines for the management of inhaled or ingested foreign bodies. London: BOS, 2003.





This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ross, A. P.
Right arrow Articles by Quick, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ross, A. P.
Right arrow Articles by Quick, A. N.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS