J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 36, No. 3, 145-151, September 2009 doi:10.1179/14653120723130
© 2009 British Orthodontic Society

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Squeff, L. R.
Right arrow Articles by Gouvêa, J. P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Squeff, L. R.
Right arrow Articles by Gouvêa, J. P

Scientific Section

Asymmetric headgear for differential molar movement: a study using finite element analysis

Luciana Rougemont Squeff, Antônio Carlos Oliveira Ruellas, Norman D Penedo, Carlos N Elias, Eduardo F Sant’anna, Giovana R Casaccia, Janaína C Gomes and Jayme P Gouvêa

Federal University of Rio de Janeiro, Brazil

Address for correspondence: Antônio Carlos Oliveira Ruellas, Federal University of Rio de Janeiro, Brazil., Email: antonioruellas{at}yahoo.com.br

Received 29 August 2008; accepted 5 June 2009


    Abstract
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
Objective: To compare the effects of four different asymmetric headgear systems.

Design: A mathematical method for three-dimensional data called finite element analysis.

Setting: The Orthodontic Department, the Federal University of Rio de Janeiro and the Metallurgical Engineering Department of the Fluminense Federal University.

Methods: Four systems of delivering an asymmetrical force to headgear were studied: using face-bow arms of different lengths, a symmetric face-bow with one of the arms bent outward in relation to the internal arch, a symmetric face-bow used in combination with a transpalatal arch activated to produce an asymmetric force, and a symmetric face-bow with the outer bow soldered to the inner bow on the side where a larger force will be applied.

Results: All four systems were effective in promoting asymmetric distal movement of the molars. However, the symmetrical face-bow with the outer bow soldered to the inner bow (system 4) could be used in asymmetric mechanics if the bows are soldered on the opposite side to the proposed distalization. Lateral and occlusal displacing forces were observed in all systems as well as tip-back and rotational movements.

Conclusion: The simulated computer model used in this investigation suggests that a face-bow with a symmetrically soldered joint and arms of equal lengths used in combination with a transpalatal arch is the best headgear option when asymmetric movement of upper molars is desired.

Key words: Asymmetrical force, headgear system, class II malocclusion, orthodontic treatment


    Introduction
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
Headgear is a common option for the treatment of class II malocclusion.1Go,2Go Compared with other techniques used to distalize molars such as intra-oral appliances and mini-implants,3Go headgear is the choice when restraint of maxillary growth and dental movement are required. There is a consensus that headgear inhibits anterior growth of the maxilla, which contributes to the correction of the anteroposterior discrepancy between the maxillary and the mandibular dentitions.1Go,4Go

Headgear might also be adapted to correct an asymmetrical class II molar relationship. Various asymmetric face-bows have been designed to produce unilateral molar movements, including using different lengths of outer or inner bows (shortening or elongating one arm), alternative right/left angulations between the outer and inner bows, or by introducing a swivel offset or hinged inner bow, and other combinations.5Go8Go

The finite element analysis, developed initially for studies in the field of the engineering, has been applied in dental biomechanical research since 1973, to analyse the stress and strain fields in the alveolar support structures.9Go11Go This is a useful method to quantify forces, moments and tensions, as well as other variables that allow appliance activations to be simulated for distal movement according to coordinates X, Y and Z.12Go It is based on the separation of the analysis shape into subdomains through finite elements, allowing the prediction of the mechanical behaviour of the object under varied loading conditions.12Go

Several investigations have examined the use of asymmetric headgear systems; however there has been little consensus as to which method is the most effective.8Go,13Go,14Go The aim of this study was to compare the effects of four different asymmetric systems for applying forces to the maxillary first molar movement during headgear treatment using a mathematic method for three-dimensional data; finite element analysis.


    Material and methods
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
The four asymmetric headgear systems (50.11.001; Morelli, São Paulo, Brazil) studied were produced by the same operator based on measurements made from the study casts of one patient. The upper first molars were asymmetric, with the right first molar more mesially positioned than the left one by 2 mm. These values were obtained with a digital calliper (797B; Starrett, São Paulo, Brazil) and then transferred to a schematic drawing on graph paper according to Cartesian coordinates (X, Y and Z). The zero point was placed at the centre of a tangent line placed on the distal face of the upper second molars.

The following headgear systems were analysed (Figure 1Go):


Figure 1
View larger version (13K):
[in this window]
[in a new window]

 
Figure 1 Asymmetric headgear systems studied: (a) face bow with arms of different lengths, (b) face-bow with one arm outward; (c) symmetric face-bow with asymmetric transpalatal arch and; (d) face-bow with outer bow soldered to the inner bow

 
  1. a symmetrically soldered face-bow with arms of different lengths. The modification (a reduction of 28 mm in length) was made to the left arm to produce more force on the right side (Figure 1(a)Go);
  2. a symmetrically soldered face-bow with arms of equal lengths, but with different angulations. The right arm was bent outward for application of larger force on this side. The angulation of the right outer arm was increased by 15° (Figure 1(b)Go);
  3. a face-bow with a symmetrically soldered joint and arms of equal lengths used in combination with a transpalatal arch made of 0.036'' stainless steel round wire (55.01.090, Morelli, São Paulo, Brazil) activated to produce an asymmetric force. In system 3 (Figure 1(c)Go), a modification was made to the transpalatal bar so that a 2 N force was applied to distalize the right molar. The transpalatal bar could not be simulated on a computer, therefore a 2 N force was added to the 4 N force applied to the right side of system 3, totalling 6 N distalization force;
  4. a face-bow with symmetrical arms, but with the outer bow soldered to the inner bow on the asymmetric side.

The headgear was adapted in a patient and the obtained measures were transferred for a Cartesian system. Tube brackets were applied to the buccal surface of the first molars according to the model simulation, and facebows were connected to them. Elastics were placed on each facebow hook and then connected to cervical pull headgear. The centre of resistance for the molars was located in the apical third of the teeth, so that the cervical pull resulted in a line of force below the centre of resistance, with each side releasing a 4 N distal force.

The maxillary structures were created through ANSYS software, version 7.0 (Swanson Analysis System, Canonsburg, PA) using the finite element method (Figure 2Go). The finite element method was established based on the discretization of the geometrical model into several parts that were connected to each other through points called nodes. For each finite element, interpolation functions were established, which allow the structural behaviour of this area to be simulated according to the different properties of each element (teeth, alveolar lamina dura, bracket, headgear appliance, and periodontal ligament fibres) and their characteristic structural response. The mechanical properties of both organic tissues and orthodontic materials, particularly elasticity and Poisson’s coefficient, were obtained from the literature,15Go18Go thus characterizing the numeric module for finite elements. In order to simplify the model the properties of other structures, such as organic tissues and orthodontic materials were considered to be linear, homogeneous, and isotropic.17Go19Go


Figure 2
View larger version (26K):
[in this window]
[in a new window]

 
Figure 2 Finite element method applied to an asymmetric system. The coordinate X indicates mesial-distal movement, the coordinate Y indicates buccal-palatal movement and the coordinate Z indicates cervical-occlusal movement

 
For the purpose of initial dental movement and deformation of the periodontal fibres, the tooth was considered to be a rigid body that suffers no deformation. In addition, the differentiation between enamel and cement was not taken into account in order to simplify the model, and a single value was used to represent the tooth property. The values attributed for characterizing the tooth behaviour were 20,000 MPa for the modulus of elasticity10Go,16Go,18Go and 0.30 for the Poisson’s coefficient.20Go22Go The alveolar lamina dura (also considered a rigid body) was attributed the cortical bone properties with mean values of 13,800 MPa for the modulus of elasticity and 0.30 for the Poisson’s coefficient.10Go,17Go,20Go22Go The values attributed to orthodontic brackets, all made of stainless steel, were 180,000 MPa for the modulus of elasticity and 0.30 for Poisson’s coefficient, whereas the periodontal ligament was attributed 0.05 MPa to characterize the finite element model, the smallest and more frequent value found in the literature.10Go,16Go A Poisson’s coefficient of 0.49 has been used to characterize the incompressible materials in several studies.21Go23Go

The computer simulations were performed on a desktop computer with the following configuration: Intel Pentium 4 with 2.8 GHz processor, 80 Gb Hard Disk, and 1 Gb RAM. The simulations were run by using the same ANSYS software. Each simulation was carried out once. Repetitions were only undertaken in order to adjust the developed model.

Statistical analysis
The simulations produced with the finite element method only represented the initial movement of the first molars. For this reason, the results do not exhibit significant quantitative differences in the distal molar movement and the values were not submitted to hypothesis testing, but are presented using a descriptive analysis.


    Results
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
Table 1Go shows the resulting forces on the upper first molars in the mesial-distal direction (X-coordinate). System 3 produced the greatest difference between the resulting distal forces on the right side and left sides: 2.03 N (3.21 N on the left side and 5.24 N on the right side). System 1 showed a distal force difference of 1.74 N of distal force between left and right sides, while system 2 produced a difference of only 0.08 N between both sides. Interestingly, system 4 had an unexpected result, with a smaller distalizing force of 0.7 N on the right molar as the left molar.


View this table:
[in this window]
[in a new window]

 
Table 1 Resulting forces in the mesial direction (X-coordinate)
 
Table 2Go shows the resulting forces on the upper first molars in the buccal-palatal direction (Y coordinate). Lateral displacing forces were observed in all systems: a force in the palatal direction on the right side and a force in the buccal direction on the left side. System 3, showed the smallest lateral forces (a buccal force of 0.25 N on the left side and a palatal force of 0.25 N on the right side) whereas system 4, showed the greatest lateral forces (a buccal force of 1.72 N on the left side and a palatal force of 1.56 N on the right side).


View this table:
[in this window]
[in a new window]

 
Table 2 Resulting forces in the buccal-palatal direction (Y-coordinate)
 
Table 3Go shows the resulting forces in the cervical-occlusal direction (Z-coordinates). All systems tended to promote forces in the occlusal direction or extrusive movement. Application of a greater force on either side also resulted in a greater extrusive force, except for system 3, where the right side received an occlusal force of 1.19 N compared to 1.22 N on the left side.


View this table:
[in this window]
[in a new window]

 
Table 3 Resulting forces in the cervical-occlusal direction (Z-coordinate)
 
Figure 3Go shows that the displacement resulting from the activation of the four asymmetric headgear systems produced a distal movement of the crown in all systems. At the bottom of the figure is a colour scale representing the amount of molar movement. Blue shades to the left represent little or no movement and red shades to the right represent maximum movement. There is a colour gradation from the roots of the teeth to the crowns, which indicates a tip-back movement. Rotational movement was also present in all system after extra-oral force application (Figure 4Go), but this was smallest for the upper left molar in system 3.


Figure 3
View larger version (56K):
[in this window]
[in a new window]

 
Figure 3 Computer simulation of the initial molar movement from the four systems after extra-oral force application. The degree of displacement is represented by the colour scale (blue: little or no movement; red: greatest amount of movement; molars in the right posterior view)

 

Figure 4
View larger version (48K):
[in this window]
[in a new window]

 
Figure 4 Rotational movement of the molars from the four systems after extra-oral force application. The degree of displacement is represented by the colour scale (blue: little or no movement; red: greatest amount of movement)

 

    Discussion
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
The application of computer simulations using finite element analysis showed to be an efficient method to study asymmetric headgear systems, being observed that the four researched types were effective in promoting asymmetric distal movement of the molars.

Analytical mathematical models can be criticized as not being true representations of dental structures, including the diversity of substances of tooth composition and anatomical irregularity. Experimental techniques in humans or animals are also limited because of the possible error caused by variables like tension and compression values in the periodontal ligament and individual variation. Finite element analysis is a possible solution to these problems because of the capacity to mathematically model complex structures with irregular geometries like teeth and biomaterials.12Go The technique has been use to produce models in several dental specialties24Go,25Go including orthodontics;9Go,11Go,12Go,21Go however as far as we are aware it has not been used to model orthodontic extra-oral systems. One major drawback is the inability to reproduce the cell functions and chemical mediators of inflammation during dental movement. In addition to the biological complexities, the variations of the individual response to orthodontic forces could not be observed through a computerized method.26Go Therefore, our analysis was based on the initial movement of the teeth in response to the forces exerted by each of the four systems studied.

In relation to the asymmetric distal movement of the molars, all systems were shown to be effective, but the best result was presented by system 3 (Table 1Go) which means that it was the best choice for producing asymmetric distal force. This result also reinforces the findings of Melsen et al.14Go who suggested using a transpalatal bar in associated with headgear and activating it on the side where a greater distal force is required. The headgear acts by neutralizing the mesial force on the opposite molar, thus controlling the rotational movement and optimizing the distal force on the desired side. System 1 was also effective in producing an asymmetric distal force. This finding is in accordance with other authors,5Go,13Go,27Go who recommend an increase in the outer bow length on the side needing greater distalization. System 2 was less effective in producing an asymmetrical distal force. Other authors6Go,13Go have also found that expanding one of the outer bow side without altering its length is ineffective, since the angulation between force line and sagittal median line is virtually kept unchanged. In addition, the authors have pointed to the fact that the lateral force component increases under such situations without favouring the anteroposterior position of the molar. Therefore expansion of one of the outer bow sides with no correspondent increase in length is not an appropriate choice for producing a greater distal force.

System 4 was based on work carried out by Jacobson2Go who modified the extra-oral arch by displacing the welded joint position attaching the outer and inner bows towards the side where distal molar movement is desired. He found a greater force on the side the welded joint was displaced toward, but he attributed this difference to the increased flexibility on the opposite side that, due to appliance activation, would suffer a greater deformation, reducing the angulation between the force line and sagittal plane and altering the resulting force vector. According to these findings, headgear system 4 was welded to a rigid wire segment, thus linking the outer arm to the inner one in order to make the extra-oral arch more rigid at the side where distalization is desired and consequently providing a greater flexibility at the opposite side; however, a lesser distal force was observed at the side where a greater distalization movement of the molar was expected. We can conclude that this system yields a discrete asymmetric distal force at the side having higher flexibility, a finding not corroborated by Jacobson. On the other hand same authors,8Go,13Go do not believe in the efficacy of this system in producing extra-oral forces asymmetrically.

Movements in the buccal-palatal direction are generally undesirable and very difficult to control.27Go,28Go Lateral displacing forces were found in all the systems in this study, with movement in the palatal direction on the right side and in the buccal direction on the left side. This has been found in other studies5Go,29Go,30Go and can result in a posterior cross-bite on the side receiving more distal force. According to Yoshida et al.,29Go the lateral dislocation is directly proportional to the asymmetry existing in the outer arch. That is, the more asymmetric the outer bow, the greater the buccopalatal movement of the distalized molars. Other authors8Go,31Go had observed buccal displacement on both sides, which could be attributed to discrepancies in the face-bow configurations.29Go System 3 showed the best results in the lateral direction, because the forces were low and equal on both sides. This result was expected since the transpalatal bar acts by controlling lateral movements.14Go

With regard to the occlusal or z-direction forces, we expected to observe extrusion of the first molars in all headgear systems studied as cervical extra-oral traction was employed and the greater the force applied, the greater the tendency for extrusion. According to this same rationale, it was possible to predict that the right molar (the tooth expected to undergo the greater distalization) might suffer an extrusion greater than that of the left molar. As expected in this study and previous studies,1Go,28Go,30Go we observed the predicted outcome on three of the four systems submitted to computer simulation. System 3 showed a similar extrusive force on both and this result was attributed to the transpalatal bar that equilibrated the system by promoting occlusal movements of similar intensity on the right and left sides. The control of vertical force can be achieved by altering the angulation of the outer arms of the facebow, although Altug et al.28Go advise that in such cases a decreased distal force will be achieved.

The line of force passed below the centre of resistance of the first molars in the model used in this simulation, therefore it was expected that these teeth would tip distally instead of moving bodily. This supposition was confirmed (Figure 3Go) and is corroborated in the literature27Go as the molar models made for this computer simulation had their centre of resistance located in the apical third of the root (this result was obtained by mistake in the elaboration of the drawing of the tooth molar in the computer model).

Distal rotation is another movement associated with the mechanics of distal movement, because the force application point is located on the buccal face of the crown.5Go,14Go,29Go In Figure 4Go, it can be observed that this rotational movement happened in all systems, but in system 3 this effect was smaller on the upper left molar. This was expected because of the role played by the transpalatal bar, which neutralizes the movements of distalization and rotation.14Go Although distal rotation is not desired, according to Yoshida et al,29Go it is not a reason for concern as this movement is favourable because the upper first molars in Class II malocclusions are frequently mesially rotated.


    Conclusions
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
Computer simulations using finite element method for asymmetric headgear systems studied showed that:


    Contributor statement
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
Luciana R. Squeff and Antônio Carlos O. Ruellas were responsible for the reproduction of the headgear systems and all the measures for the application of the finite element method, data interpretation and final approval of the article. Norman D Penedo was responsible for the elaboration and application of the finite element method. Eduardo F Sant’anna, Giovana R Casaccia, Janaína C Gomes, Carlos N Elias and Jayme P Gouvêa were responsible for critical revision. Luciana R. Squeff is the guarantor.


    References
 Top
 Abstract
 Introduction
 Material and methods
 Results
 Discussion
 Conclusions
 Contributor statement
 References
 
1 Ashmore JL, Kurland BF, King GJ, Wheeler TT, Ghafari J, Ramsay DS. A 3-dimensional analysis of molar movement during headgear treatment. Am J Orthod Dentofacial Orthop 2002; 121: 18–29.[CrossRef][Medline]

2 Jacobson A. A key to the understanding of extraoral forces. Am J Orthod 1979; 75: 361–386.[CrossRef][Medline]

3 Benson PE, Tinsley D, O’Dwyer JJ, Majumdar A, Doyle P, Sandler PJ. Midpalatal implants vs headgear for orthodontic anchorage – a randomized clinical trial: cephalometric results. Am J Orthod Dentofacial Orthop 2007; 132: 606–15.[CrossRef][Medline]

4 Tullock JF, Phillips C, Koch G, Proffit W. The effect of early intervention on skeletal pattern in class II malocclusion: a randomized clinical trial. Am J Orthod Dentofacial Orthop 1997; 111: 391–400.[CrossRef][Medline]

5 Brosh T, Portal S, Sarne O, Vardimon AD. Unequal outer and inner bow configurations: Comparing 2 asymmetric headgear systems. Am J Orthod Dentofacial Orthop 2005; 128: 68–77.[CrossRef][Medline]

6 Rubin RM. Analysis of component forces induced with several types of cervical traction appliances. Am J Orthod 1961; 48: 552–53.[CrossRef]

7 Haack DC, Weinstein S. The mechanics of centric and eccentric cervical traction. Am J Orthod 1958; 44: 346–57.[CrossRef]

8 Hershey HG, Houghton CW, Burstone CJ. Unilateral face-bows: a theoretical and laboratory analysys. Am J Orthod 1981; 79: 229–49.[CrossRef][Medline]

9 Tanne K, Sakuda M, Burstone CJ. Tree-dimensional finite element analysis for stress in periodontal tissue by orthodontic forces. Am J Orthod Dentofacial Orthop 1987; 92: 499–505.[CrossRef][Medline]

10 Bourauel C, Vollmer D, Jager A. Application of bone remodeling theories in the simulation of orthodontic tooth movements. J Orofacial Orthop 2000; 61: 266–79.[CrossRef]

11 Cattaneo PM, Dalstra M, Melsen B. The transfer of occlusal forces through the maxillary molars: a finite element study. Am J Orthod Dentofacial Orthop 2003; 123: 367–73.[CrossRef][Medline]

12 Coimbra MER, Penedo ND, Gouvêa JP, Elias CN, Araújo MTS, Coelho PG. Mechanical testing and finite element analysis of orthodontic teardrop loop. Am J Orthod Dentofacial Orthop 2008; 133: 188e9–13.

13 Oosthuizen L, Dijkman JFP, Evans WG. A mechanical appraisal of the Kloehn extraoral assembly. Angle Orthod 1973; 43: 221–32.[Medline]

14 Melsen B, Bonetti G, Giunta D. Statically determinate transpalatal arches. J Clin Orthod 1994; 28: 602–06.[Medline]

15 Chen F, Terada K, Handa K. Anchorage effect of various shape palatal osseointegrated implants: a finite element study. Angle Orthod 2005; 75: 344–51.[Medline]

16 Poppe M, Bourauel C, Jager A. Determination of the elasticity parameters of the human periodontal ligament and the location of the center of resistance of single-rooted teeth a study of autopsy specimens and their conversion into finite element models. J Orofacial Orthop 2002; 63: 358–70.[CrossRef]

17 Jones Ml, Hickman J, Middleton J, Knox J, Volp C. A validated finite element method study of orthodontic tooth movement in the human subject. J Orthod 2001; 28: 29–38.[Abstract/Free Full Text]

18 Jeon PD, Turley K, Ting K. Three-dimensional finite element analysis of stress in the periodontal ligament of the maxillary first molar with simulated bone loss. Am J Orthod Dentofacial Orthop 2001; 119: 498–504.[CrossRef][Medline]

19 Schneider J, Geiger M, Sander FG. Numerical experiments on orthodontic tooth movement. Am J Orthod Dentofacial Orthop 2002; 121: 257–65.[CrossRef][Medline]

20 Katona TR, Quian H. A mechanism of noncontinuous supraosseous tooth eruption. Am J Orthod Dentofacial Orthop 2001; 120: 263.[CrossRef][Medline]

21 Vásquez M, Calao E, Becerra F, Ossa J, Enríquez C, Fresneda E. Inicial stress differences between sliding and sectional mechanics with an endosseous implant as anchorage: a 3-dimensional finite element analysis. Angle Orthod 2001; 71: 247–56.[Medline]

22 Rees JS, Jacobsen PH. Elastic Modulus of the periodontal ligament. Biomaterials 1997; 18: 991–95.

23 Rudolph DJ, Willes PMG, Sameshima GT. A finite element model of apical force distribution from orthodontic tooth movement. Angle Orthod 2001; 71: 127–31.[Medline]

24 Cook SD, Weinstein AM, Klawitter JJ. A three-dimensional finite element analysis of porous rooted Co–Cr–Mo alloy dental implant. J Dent Res 1982; 61: 25–29.[Abstract/Free Full Text]

25 Beek M, Koolstra JH, Van Ruijven LJ, Van Eijden TM. Three-dimensional finite element analysis of the cartilaginous structures in the human temporomandibular joint. J Dent Res 2001; 80: 1913–18.[Abstract/Free Full Text]

26 Böhn MV, Maltha JC, Hoff JWVD, Kuijpers-Jagtman AM. Focal hyalinization during experimental tooth movement in beagle dogs. Am J Orthod Dentofacial Orthop 2004; 125: 615–23.[CrossRef][Medline]

27 Wohl TS, Bamonte E, Pearson HE. Nonextraction treatment of unilateral Class II, division 1 malocclusion with asymmetric headgear. Am J Orthod Dentofacial Orthop 1998; 113: 483–87.[CrossRef][Medline]

28 Altug H, Bengi O, Akin E, Karacay S. Dentofacial effects of asymmetric headgear and cervical headgear with removable plate on unilateral molar distalization. Angle Orthod 2005; 75: 584–92.[Medline]

29 Yoshida N, Jost-Brinkmann P, Miethke R, König M, Yamada Y. An experimental evaluation of effects and side effects of asymmetric face-bows in the light of in vivo measurements of initial tooth movements. Am J Orthod Dentofacial Orthop 1998; 113: 558–66.[CrossRef][Medline]

30 Baldini G. Unilateral headgear: lateral forces as unavoidable side effects. Am J Orthod Dentofacial Orthop 1980; 77: 333–39.

31 Nobel PM, Waters NE. Investigation into the behavior of symmetrically and asymmetrically activated face-bows. Am J Orthod Dentofacial Orthop 1992; 101: 330–41.[CrossRef][Medline]





This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Squeff, L. R.
Right arrow Articles by Gouvêa, J. P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Squeff, L. R.
Right arrow Articles by Gouvêa, J. P


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS