Scientific Section |
New Jersey Dental School, University of Medicine and Dentistry of New Jersey, NJ, USA
Address for correspondence: Anil P Ardeshna, New Jersey Dental School, University of Medicine and Dentistry of New Jersey, NJ, USA. Email: ardeshap{at}umdnj.edu; ardeshna{at}yahoo.com
Received 30 September 2008; accepted 5 June 2009
| Abstract |
|---|
|
|
|---|
Design: An in vitro laboratory study
Materials and methods: Coloured and clear orthodontic elastomeric modules from four companies were exposed to coffee, cola, tea and spices for 72 h. The difference in colour components was measured with a Minolta chromameter before and after exposure.
Results: Significant changes in colour, including grey level and chromaticity, both as a function of colour and company of elastomeric ligature module were found following exposure to beverages and spices. Colour change was most affected by
b* (yellowness) and most significant in clear modules. Modules made using injection mouldings were more resistant to colour change than those by extrusion. Spice mix had the most effect and cola beverage the least. Clinically, these changes compromised both colour stability and esthetics of the elastomeric module.
Conclusions: Clinicians should make patients aware of the effect of consuming beverages and spices on the colour stability of their selected ligature modules. Clinicians should favour modules made with injection moulding. Darker colour modules may be preferred to clear modules to avoid excessive colour degradation through dietary media such as beverages and food spices. Patients consuming large amounts of spices or coffee should avoid clear modules made by extrusion processing because of their tendency to discolour.
Key words: Colour, orthodontic materials, staining, elastomers, aesthetics
| Introduction |
|---|
|
|
|---|
Concerns have been raised regarding the quality of the products and whether one company is superior to another in efficacy or cost-effectiveness. Many studies have been carried out comparing product performance such as force decay, friction and dimensional changes of these elastomeric modules.5
–9
For example, the question as to whether force delivery is affected by pigmenting of the elastomer has been studied elsewhere.6
,9
Structural conformation and degradation have also been examined.11
–15
Although the modules have been reported to be susceptible to staining in the oral environment, to the best of our knowledge, no systematic studies on colour stability of these modules have been reported previously.16
The ability to prevent intrinsic and extrinsic stains of the polyurethanes modules has become an important challenge, as the oral environment is exposed to a variety of media on a daily basis, many of which may stain or alter the surface of modules causing aesthetic degradation. It is therefore important to know, not only whether long-term exposure to daily beverages and spices changes the colour of the module, but also whether it is a change that is perceivable by the human eye.
Colour plays an important role in many aspects of dentistry, particularly shade matching of restorations and tooth whitening products.17
Several studies have been carried out on the staining effects of beverages namely, coffee, tea and wine, which are normally associated with adult tooth stain on composite restorations and tooth bleaching.18
–22
Extended exposure to cola is known to cause colour changes of restorative composites.21
,22
and may also cause discolouration of orthodontic elastomeric ligature modules. Spices and seasoning are also known to cause extrinsic staining of teeth. They are essential in processed foods (prepared foods, snacks, sauces, condiments, salad dressings) and ethnic foods, especially Mexican, Italian, and Asian.
The objective of this study was to evaluate the role of spices and beverages namely, coffee, tea and cola in the discolouration of popular clear and coloured elastomeric modules used in orthodontics. The study examined whether colour changes of elastomeric modules due to dietary media exposure varied by:
| Materials and methods |
|---|
|
|
|---|
Elastomeric samples of different colours were tested before and after 72 h immersion in four different dietary media. The total number of samples tested was 960 (15 different module typesx4 different dietary mediax16 specimens). Square specimens (8x8 mm) were cut from the bulk elastomeric stick or ribbon. To ensure blinding and randomization, specimens were number-coded and randomly selected for the tests. They were rinsed with distilled water for 10 s, air-dried for 5 min and initial colour readings taken. A Minolta Chromameter (model CR-221, Minolta Corp., Osaka, Japan) with a probe diameter of 3 mm and white background was used to measure the colour dimensions. Each sample was then placed in a glass container with one of the four media at 37°C and allowed to soak for 72 h. They were then removed, rinsed, air dried and final colour readings taken.
All measurements were done in the internationally standardized CIELAB colour space23
described below. The advantages of this system for colour measurement is that it more closely represents human sensitivity to colour and equal distances in this system approximately equal perceived colour differences.17
The CIE L*a*b* colour space consists of three coordinates L*, a*, b*, as shown in Figure 1
. The L* refers to the lightness coordinate and its value ranges from zero for perfect black to 100 for perfect white. The a* is the chromaticity coordinate in the red-green axis. Positive a* values cover the red colour range and negative values indicate green colour range. The b* is the chromaticity coordinate in the yellow-blue axis. Positive b* values cover the yellow colour range and negative values indicate blue colour range.
|
L*,
a* and
b*) as a result of exposure to diet substances were determined first and the total colour change (
E) was also calculated using the relationship:
![]() |
where
L* = Lf* – Li*,
a* = af* – ai* and
b* = bf* – bi*, in which the subscripts f and i represent the final and initial values corresponding to after and before environmental exposures, respectively.
The computed value of
E is traditionally used to assess colour changes. Differences of one or two units in
E may indicate some perceptible stain. A detailed study by Ruyter et al.18
has shown that a shift in
E value of >3.3 reflects a change that is a clinically significant visual discolouration. The
E value for each company-colour-media condition subset can therefore be used to assess whether the changes are visually and clinically significant between the subsets. It is also often equally important to understand the relative changes in the individual colour components (i.e.
L*,
a*,
b*) for a full understanding of the complex changes of colour in elastomeric modules under environmental condition. This study focused on the total colour change
E as well as changes in the three individual colour components
L*,
a* and
b*).
Statistical analysis
Preliminary analyses were carried out to confirm that intra-sample colour differences were minimal. Repeated colour measurements on selected specimens at two time points with a gap of 24 h showed less than 1% variation, indicating high reproducibility in measurements.
Preliminary data from a pilot study was used to determine the sample size. A two-factor design (using four media and clear modules from four different companies) was used in the pilot study. The effect size was determined as 0.217 from the range of group means (1.43) and the within-cell SD (6.60), and the sample size was determined at
=0.05 for a specified 80% minimum power. A sample size, n=16 was selected for the study, and corresponded to ~84% power.
The dependent variables were the calculated values of
L*,
a*,
b* and
E using the measured differences in L*, a* and b* before and after soaking 72 h in media, as described earlier. The independent variables included colour of elastomeric module, company, and type of dietary media. Since different companies marketed modules with different colours, the colours and media effects on modules were tested separately for each company. Consequently, statistical analyses of all treatment comparisons were done using a two-way analysis of variance (ANOVA) at P=0.05 level of significance to examine differences due to the main effects and interactions among these two independent variables in parallel tests for each company. Since the measured and calculated values yielded four sets of data outcomes (namely
L*,
a*,
b* and
E), they were all analysed in parallel two-way ANOVA tests for each outcome, for each of the four companies. Such an analysis focusing on both total colour change and specific changes in individual colour components is useful to understand the nature of the colour degradation. The Tukey-Kramer (HSD) test was also used to show the results of the contrasts of colour and media effects within each company. All analysis was done using SPSS [SPSS, for Windows (v.16), Chicago, IL, USA].
| Results |
|---|
|
|
|---|
|
|
|
E of modules from American Orthodontics when subjected to different dietary media exposure. The Ruyter criterion of a visually detectable colour change at
E>3.3 is also indicated by the horizontal line. Statistically highly significant colour changes (P<0.0001) were seen for all colours when subjected to spices, coffee and tea. In addition they also represented clinically significant changes as was evident from both Ruyter criteria and visual discolouration in the samples. Cola had a reduced effect on discolouration particularly on grey and green modules, and although statistically significant, no discolouration was visually detected in these samples and the
E values were <3.3. Figure 3(a–d)
|
|
L*,
a*,
b*) are shown in Table 4
L*, which indexes colour on the grey scale, ranged between a minimum of – 1.70 and a maximum of – 17.37. This range indicates a darkening of the samples over time. The values of a* varied in the range between – 18.00 and +10.56, which indicated a trend towards green continuum for most samples except white and green which shifted towards the red. For the b* value, the samples displayed values within the range from 1.98 to 46.18, which indicates that all the observations were on the yellow side of this colour continuum.
|
L*>– 10.0) for the white coloured modules in coffee was observed. Clinically, it also represented a visual darkening of the grey level. This was also observed to some extent with the clear and blue colours. Neither grey nor green modules were found to have statistically significant (P>0.05) or visually detectable changes in the L* value.
|
a*) in the red-green axis. In contrast, the blue coloured modules shifted significantly to the more greenish chroma. Clear and grey showed slight changes, which were not considered clinically significant. The changes in b* were more dramatic and significant for all colours compared to L* or a*. From a clinical perspective, the changes in b* were visually detectable changes. The samples all became appreciably more yellow regardless of colour. Clear, white and blue showed the most changes and green the least.
| Discussion |
|---|
|
|
|---|
Clinically, aesthetics is a significant reason for the selection of coloured modules in orthodontic practice, and staining of elastomeric modules is therefore a major concern for both patients and practitioner. This study identified important criteria to select a module, taking into account the performance profile of the module based on its colour, processing method and brand, as well as the individuals own beverage/spice consumption habits. Clinicians can use such criteria for elastomeric modules for improved aesthetic durability of the modules used in clinical practice.
There are, however, some important limitations of the study that also need to be considered. The elastomeric modules themselves were not used in this study because they are too small for direct colour measurements using the Chromameter. Instead, 8x8 mm square sections were used. Pigment uptake is potentially related to the water uptake, and the resulting swelling of the polymer. The surface area to volume ratio of the samples may strongly influence the water uptake, and the results of this study may not therefore represent the absolute changes in colours of the elastomeric modules; however, we are primarily interested in the relative changes, and the relative changes will be reflected by the ranked differences.
Multiple comparisons were used to detect significant differences in this study. Since the experimental design involved four outcomes with three factors at three to four levels, close to 40 multiple comparisons were involved. Such a large number of multiple comparisons with the same data may increase the chance of a type I error by incorrectly identifying a significant difference where none exists. For this reason, we used visual observations of differences to confirm the most important statistical test outcomes of interest, where possible.
This investigation was an in vitro study, and some additional differences with clinical situations must be pointed out. For example, there was no consideration of the surrounding area such as shade of the tooth, metal versus clear brackets, lightening within the mouth that would play a role in the clinical situation. The study did not simulate the role of saliva and oral clearance on slowing down the long term build up of stains in the oral environment. The saliva within the oral cavity functions to dilute the concentration of the ingested beverage. Often saliva can also function as a buffer for the pH of the beverage. Moreover, the study did not address the issue of differences between individuals expected in vivo. It has also been shown that in vivo, a non-continuous proteinaceous biofilm forms on the surface of the modules.11
The effect of the dietary media on this biofilm and possible effect on colour was not examined. The concentration of the media would have a definite impact on the staining potential; therefore it is possible that different brands of coffee, tea and cola would have a different effect as would brewing methods. Red wine has been found to be a significant stainant of aesthetic resin restorations.19
With adult orthodontic patients being possible red wine drinkers this could potentially be an important stainant to examine in future studies. In addition, besides colour, there are other factors that favour choice of elastomeric modules in patients.
A number of factors are known to influence colour stability. The chemical composition and specific details of processing and manufacturing, although proprietary for each of the companies, are important variables. The extrusion/die stamp processed modules (3M/Unitek, ORMCO, TP) typically showed more staining than injection moulded elastomer (American Orthodontics). The synthesis of polyurethane involves multiple steps. The polyurethane is the final product of many chemical reactions involving several compounds. Thus polyurethanes with different chemical profiles can be produced.2
,3
The interaction of their active chemical groups with additives that have been added for processing or filler material for tinting will be different. Chemistry also influences the configuration of the chains of the elastomer and their ability to withstand deterioration from external agents and processing conditions. Processing conditions may also affect the structure and configuration of the polymeric chains. In addition the surface characteristics such as texture, porosity could be different.
Exposure to water, enzymes, chemicals and heat have been shown to have an effect on the structure and glass transition temperature (Tg) of the materials. A difference in Tg is indicative of different molecular configuration and structure. A higher Tg indicates a more rigid polymer due to the presence of more cross-linked type of covalent bonding or larger side chains causing steric interferences. Evangelista et al.14
found that there was significant difference amongst companies of elastomeric ligatures in tensile load at failure and Tg when exposed to disinfectant solutions. Huget15
studied the changes in elasticity of orthodontic elastomers when stored in water. He suggested that exposure to water leads first to weakening of noncovalent bonds (intermolecular forces) and concurrent formation of hydrogen bonds between water molecules and macromolecules. The water functions initially as a plasticizer and facilitates slippage of molecules or chain segments past each other. Subsequently there is chemical degradation where polyester urethanes are decomposed by addition of water across ester linkages rather than linkages. This reaction is catalysed by acid, and hence a low pH such as from cola further facilitates this hydrolysis of the polymer. Substances are leached from the polymer over time, and it would be plausible that pigments and other compounds from the beverages and species could penetrate deep into the polymer structure and cause discolouration.
Collection of pigments could also occur on the surface. Textural and morphological changes at the surface may have also contributed to the differences amongst companies. Morphological changes such as surface porosity and roughness are known to adversely affect colour perception due to the fact that the surface texture can significantly modify light scattering effects. Extruded modules may exhibit more porosity due to air entrapment during processing. Microcracks during processing could cause light scattering due to the rough morphology, and further penetration of pigments contributing to greater stain and discolouration of the sample.
The clear elastomers of all the companies consistently showed colour changes that would not be acceptable clinically to adults consuming a lot of spices or coffee and tea, but they were clinically acceptable to patients consuming cola beverages.
From a clinical perspective, this study has demonstrated that coloured and clear orthodontic elastomeric ties are prone to significant change of colour/stain in the oral environment. Clinicians should be aware that colour stability of orthodontic ties will vary between vendors and manufacturing process. Orthodontic patients should be aware that different colour ties will change colour to different degrees. These changes are influenced by the spices in the food and types of beverages they drink. The aesthetic considerations for improved colour stability must therefore play an important role in the selection of coloured elastomeric modules for clinical use.
| Conclusions |
|---|
|
|
|---|
| Contributor statement |
|---|
|
|
|---|
| References |
|---|
|
|
|---|
2 Zdrahala RJ, Zdrahala I. J. Biomedical applications of polyurethanes: a review of past promises, present realities, and a vibrant future. J Biomater Appl 1999; 14: 67–90.
3 Brantley WA, Eliades T. Orthodontic materials: scientific and clinical aspects. Stuttgart: Thieme, 2001, 173–87.
4 Kidd PD, Sterrett TL. The use of thermoplastic polyurethane elastomers in orthodontics. J Elastomers Plast 1984; 16: 199–205.[CrossRef]
5 Baty DL, Storie DJ, Von Fraunhofer JA. Synthetic elastomeric chains. A literature review. Am J Orthod Dentofacial Orthop 1994; 105: 536–42.[Medline]
6 Baty DL, Volz JE, Von Fraunhofer JA. Force delivery properties of colored elastomeric modules. Am J Orthod Dentofacial Orthop 1994; 106: 40–46.[CrossRef][Medline]
7 Bousquet Jr JA, Tuesta O, Flores-Mir C. In vivo comparison of force decay between injection molded and die-cut stamped elastomers. Am J Orthod Dentofacial Orthop 2006; 129: 384–89.[CrossRef][Medline]
8 De Genova DC, McInnes-Ledoux P, Weinberg R, Shaye R. Force degradation of orthodontic elastomeric chains—a product comparison study. Am J Orthod Dentofacial Orthop 1985; 87: 377–84.
9 Taloumis LJ, Smith TM, Hondrum SO, Lorton L. Force decay and deformation of orthodontic elastomeric ligatures. Am J Orthod Dentofacial Orthop 1997; 111: 1–11.[CrossRef][Medline]
10 Renick MR, Brantley WA, Beck FM, Vig KW, Webb CS. Studies of orthodontic elastomeric modules. Part 1: glass transition temperatures for representative pigmented products in the as-received condition and after orthodontic use. Am J Orthod Dentofacial Orthop 2004; 126: 337–43.[CrossRef][Medline]
11 Eliades T, Eliades G, Watts DC. Structural conformation of in vitro and in vivo aged orthodontic elastomeric modules. Eur J Orthod 1999; 21: 649–58.
12 Eliades T, Eliades G, Silikas N, Watts DC. In vitro degradation of polyurethane orthodontic elastomeric modules. J Oral Rehabil 2005; 32: 72–77.[CrossRef][Medline]
13 Stevenson JS, Kusy RP. Structural degradation of polyurethane-based elastomeric modules. J Mater Sci 1995; 6: 377–84.[CrossRef]
14 Evangelista MB, Berzins DW, Monaghan P. Effect of disinfecting solutions on the mechanical properties of orthodontic elastomeric ligatures. Angle Orthod 2007; 77: 681–87.[CrossRef][Medline]
15 Huget EF, Patrick KS, Nunez LJ. Obervations on the elastic behaviour of synthetic orthodontic elastomer. J Dent Res 1990; 69: 496–501.
16 Lew KK. Staining of clear elastomeric modules from certain foods. J Clin Orthod 1990; 24: 472–74.[Medline]
17 Burkinshaw SM. Colour in relation to dentistry. Fundamentals of colour science. Br Dent J 2004; 196: 33–41.[CrossRef][Medline]
18 Ruyter IE, Nilner K, Moller B. Color stability of dental composite resins for crown and bridge veneers. Dent Mater 1987; 3: 246–51.[CrossRef][Medline]
19 Wiltshire WA, Labuschagne PW. Staining of light-cured aesthetic resin restorative materials by different staining media: an in vitro study. J Dent Assoc S Afr 1990; 45: 561–65.[Medline]
20 Uchida H, Vaidyanathan J, Viswanadhan T, Vaidyanathan TK. Color stability of dental composites as a function of shade. J Prosthet Dent 1998; 79: 372–77.[CrossRef][Medline]
21 Fay RM, Servos T, Powers JM. Color of restorative materials after staining and bleaching. Oper Dent 1999: 24: 292–96.[Medline]
22 Abu-Bakr N, Han L., Okamoto A, Iwaku M. Color stability of compomer after immersion in various media. J Esthet Dent 2000; 12: 258–63.[CrossRef][Medline]
23 Commission Internationale de lEclairage (CIE). Recommendations on uniform color spaces, color difference equations, and metric color terms, in Suppl no. 2 to Pub. no. 15, Paris: Bureau Central de la CIE, 1978.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||