J. Orthod.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Orthodontics, Vol. 36, No. 4, 260-271, December 2009 doi:10.1179/14653120723292
© 2009 British Orthodontic Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Harradine, N.
PubMed
Right arrow Articles by Harradine, N.

Invitation to Submit

Northcroft Memorial Lecture Self-ligation: past, present and future

Nigel Harradine

Bristol Dental Hospital, Bristol, UK

Address for correspondence: Nigel Harradine, Bristol Dental Hospital, Bristol, UK. Email: Nigel.Harradine{at}bristol.ac.uk


    Introduction
 Top
 Introduction
 The past - historical...
 The present - the...
 Self-ligation - the future
 References
 
Self-ligating brackets have an archwire slot with an inbuilt labial face – usually referred to as a clip or slide, which can be opened and closed to enable placement and removal of the archwire. These brackets which incorporate their own ligation system have existed for a surprisingly long time in orthodontics (the Russell Lock edgewise attachment being described by Stolzenberg in 1935), but they have made a major impact in orthodontics only in the last decade. With the rapid proliferation of brackets (Figure 1Go) has come a growing body of literature expounding and examining the claims made on behalf of these brackets.1Go4Go This Northcroft memorial lecture aims to throw light on the subject of self-ligating brackets by looking first at the origins and context of their development, then to summarize the current hypotheses and evidence in relation to their performance and finally to give hostages to fortune by predicting some aspects of the future research into and use of self-ligation.


Figure 1
View larger version (30K):
[in this window]
[in a new window]

 
Figure 1 The number of new types of self-ligating bracket by decade

 

    The past – historical context
 Top
 Introduction
 The past - historical...
 The present - the...
 Self-ligation - the future
 References
 
Many designs for self-ligating brackets were described and patented from the 1930s, but it was not until the 1970s and 1980s that such brackets became widely available. This long gestation period was largely the result of two factors – the technical difficulty of manufacturing such brackets and the introduction in the 1960s of elastomeric ligation. The chief motivation for the development of self-ligation was the desire to speed the process of placing and removing archwires. Just removing and placing wire ligatures took an average of 16 min for a pair of archwires5Go and elastomeric ligation cut this to an average of 4 min, thus substantially reducing the need for a faster method of ligation. The concomitant disadvantages of increased friction and reduced security of archwire engagement with elastomeric ligation were not widely appreciated at the time. Edgelok (Figure 2Go, Ormco Corporation, 1717 W. Collins Ave. Orange, CA 92867) and Mobillock (Figure 3Go, Forestadent Bernhard Foerster GmbH, Westliche 151 75173 Pforzheim, Germany) were two brackets from that era. Both of these brackets had their good features, but also their deficiencies. A good example is the poor rotational control resulting from the very narrow labial surface on the upper right lateral incisor (Figure 3Go) and the corresponding need to increase the complexity of the bracket by having two labial elements on the wider central incisor. Another problem with Mobil-Lock was the difficulty of access to open and close premolar brackets with the straight ‘screwdriver’.


Figure 2
View larger version (103K):
[in this window]
[in a new window]

 
Figure 2 Edgelok bracket

 

Figure 3
View larger version (93K):
[in this window]
[in a new window]

 
Figure 3 Mobil-Lock brackets, showing the rotating labial cams and the opening and closing tool

 
A major step at that time was the introduction in 1980 of the SPEED bracket (Figure 4Go, Strite Industries Ltd, 298 Shepherd Avenue, Cambridge, Ontario, N3C 1V1 Canada). The principal engineering innovation was the use of a spring clip that was easy to manufacture with contemporary technology and was easy to open and close. Of perhaps greater long-term importance was the growing realization by Dr Hanson, the originator of the bracket, that self-ligation delivered low friction in combination with good archwire control and that this meant that teeth could be effectively and rapidly aligned with the application of much lighter forces. The effectiveness of the ligation also meant that much narrower brackets could be used with no loss of rotational control. The narrower brackets in turn brought the benefits of larger inter-bracket span which comprise lighter forces for any given wire and a longer range of action. Cases were presented and published which demonstrated the very good and perhaps surprising effectiveness of tooth alignment with these brackets, so it is natural to ask why they were only adopted by a minority of orthodontists at that time and for many years. The reasons are, I would suggest, pertinent to many new technologies introduced into dentistry and medicine.


Figure 4
View larger version (97K):
[in this window]
[in a new window]

 
Figure 4 Early SPEED brackets in 1982 with no straight-wire pre-adjustment and no slot to restrain clip deflection

 
Reasons for the slow adoption of self-ligation
Firstly, there were imperfections of design. This is always a probability with new and innovative products, however carefully they have been tested by clinicians involved in their development. Taking the original SPEED bracket as an example, the original spring clips were prone to permanent distortion and there was no feature designed to limit the labial deflection of the clip. These shortcomings resulted in loss of archwire engagement and therefore undermined a central potential advantage of self-ligation. Also, there were no tiewings which, although no longer required for ligation, remain very convenient for the placement of elastic chain or ligatures to lace teeth together. Another factor was the concurrent introduction of the pre-adjusted edgewise appliance, an innovation which had an immediate and much stronger appeal to clinicians. The original SPEED bracket was a plain edgewise bracket. All of these disadvantageous design features have long since been addressed. Figure 5Go shows a modern SPEED bracket with a fully pre-programmed slot, a retaining groove for the nickel–titanium spring clip and an additional labial hole which provides an alternative means of opening the clip. One distinctive original feature which remains is the absence of tiewings.


Figure 5
View larger version (80K):
[in this window]
[in a new window]

 
Figure 5 A modern SPEED bracket

 
Activa (Figure 6Go, ‘A’ company, San Diego, CA, USA) was introduced in 1986. It had a pre-adjusted edgewise slot, but was another self-ligating bracket with several design imperfections. The clip was rather fragile, the bracket was too wide (a consequence of the choice of clip design), the curved inner surface of the clip effectively increased the slot depth with thinner wires, there were again no tiewings and as a result of the narrow and unorthodox junction between the bracket and its bonding pad, the effective bond strength was low.


Figure 6
View larger version (118K):
[in this window]
[in a new window]

 
Figure 6 Activa brackets in 1989

 
These deficiencies were a significant factor in preventing the wide adoption of these brackets, but did not prevent good and rapid results in many cases. Figure 7Go shows a case treated in 1992 by the author with Activa brackets in 13 months.


Figure 7
View larger version (112K):
[in this window]
[in a new window]

 
Figure 7 A case treated with Activa brackets in thirteen months finished in 1992

 
Psychological factors
Psychological factors are possibly of equal importance in their influence on the adoption of new technology or new ideas. Most of us have an element of innate conservatism and a desire to stay mentally and technically within our comfort zone. We learn a skill which minimizes the deficiencies of our equipment and then we stick with it because we are comfortable. The more skilled we become in a technique (such as bending complex archwires), the more unimpressed by and resistant to a new development (such as the pre-adjusted edgewise appliance) which reduces the need for this skill. We also make treatment plans which consciously or otherwise reflect the strengths and weaknesses of our current armamentarium. It is understandable that we may have a reluctance to discard or downgrade the importance of some skills and equally we may fail to realize that some aspects of our treatment plans are chiefly there to counter deficiencies in our equipment.

The situation in the early 1990s can perhaps be summarized by saying that self-ligation had demonstrated definite and sometimes striking benefits through its potential combination of archwire control, low friction and rapid archwire changes, but substantial further development was needed to make brackets which consistently provided all the benefits with no associated weaknesses or inconvenience.

The Begg appliance
It is relevant to mention the Begg appliance and its relation to self-ligation. Begg was a low-friction appliance and it had clearly demonstrated that this enabled low forces to be highly effective in producing rapid alignment. However, its popularity waned because this freedom of tooth movement was not matched by good archwire control within the slot. The consequent heavy dependence on auxiliary attachments made the appliance complex and potentially heavy on chairside time and made precision of tooth position harder to achieve with consistency. The orthodontic world preferred the simplicity, robustness and relatively good archwire control of the pre-adjusted edgewise appliance, but in doing so, it lost the advantages of low friction and light forces. It is worth noting the illustration (Figure 8Go) from Matasa’s paper6Go in which his measurements confirm that with conventional elastomeric ligation, we can trade increased control of the archwire against low friction and ease of tooth movement, but cannot simultaneously have both.


Figure 8
View larger version (21K):
[in this window]
[in a new window]

 
Figure 8 A figure from Matasa (2001) illustrating the inability of elastomeric ligation to simultaneously provide full, secure ligation and also low friction. Brackets with ‘shoulders’ such as the Viasis bracket reduce friction, but also reduce control (reproduced with the kind permission of the author)

 

    The present – the current position of self-ligation
 Top
 Introduction
 The past - historical...
 The present - the...
 Self-ligation - the future
 References
 
The references at the start of this article contain extensive information about current brackets, clinical applications and claimed advantages, so I will be succinct on many of these aspects.

Current brackets
Figure 1Go shows that there has been an explosion of self-ligating bracket types in the last decade. The author has personal experience of fifteen different types of self-ligating brackets. This surge of activity has several causes. Firstly, manufacturing technology has advanced enormously. Metal injection moulding (MIM) and CAD-CAM technology are the two most powerful new tools enabling precise and cost-effective manufacture of small, complex bracket components. Equally important has been the momentum provided by a relatively small number of perceptive and persuasive clinicians who have enabled clinicians and manufacturers to have a much better understanding of the opportunities offered by self-ligation. Self-ligating brackets should be robust and provide consistently secure ligation with archwires of all sizes and materials. They must be easy for the clinician and comfortable for the patient to open and close with all archwires. They must be of a good size, but narrower mesio-distally than conventionally ligated brackets. It should be easy to place and remove elastomeric chain, wire underties and auxiliary hooks without impeding the operation of the clip or slide. Not all brackets meet these requirements to a sufficient degree. There are still brackets brought to the market that have significant weaknesses of design or construction, but equally there are now a number of good brackets available and therefore no practical reasons to avoid self-ligation.

Current evidence
The four core claimed advantages for self-ligation are

These core features are now sufficiently proven. Many brackets now provide reliably secure ligation, although the thoughtful study by Pandis et al.7Go reveals that it cannot be taken for granted that the designed mechanical properties of the self-ligation mechanism will be sustained throughout treatment with all the current bracket designs.

Low friction has been thoroughly demonstrated in laboratory studies with designs of greatly increased clinical relevance. Investigations by Kusy and co-workers8Go11Go are particularly recommended reading for their exploration of the effectiveness of self-ligating brackets in reducing friction when archwires are active in the slots, causing binding in addition to classical friction. A representative result from this work is that a passive self-ligating bracket when compared to a conventionally ligated bracket, reduced the resistance to sliding by 60 grams per tooth even in the presence of binding from mesiodistal tipping. Such work strongly supports the view that even though ligation is only one source of resistance to sliding, self-ligation can reduce this resistance to a clinically significant extent.

The increased speed of archwire changes may not seem immediately compelling, but with brackets being ever-easier to open and close, it is probably clinically significant. A paper by Turnbull and Birnie12Go is representative in showing an average time saving of two minutes per pair of archwires with Damon 2 brackets, which were not the easiest of brackets to open and close. In looking at such studies, it should be remembered that archwire changes with self-ligating brackets were being done by a single-handed operator and compared with four-handed changing of elastomeric ligatures.

Self-ligation and treatment efficiency
Several studies have investigated whether these established features of self-ligation result in treatment which is shorter or requires less chairside time. The hypothesis is that lower friction enables more effective relative movement between archwire and bracket and hence more rapid tooth movement whilst the reliable tooth control prevents the need to waste time regaining tooth control. Retrospective case control studies13Go15Go have indeed found greater treatment efficiency. In contrast, the more recent random controlled trials (RCTs)16Go21Go have almost all failed to show any such effect.

Possible reasons for differences between findings in treatment efficiency studies
In the retrospective studies:

In the random controlled studies:


Figure 9
View larger version (58K):
[in this window]
[in a new window]

 
Figure 9 Two examples of loss of rotational tooth control with conventional elastomeric ligation. Three of the four canine teeth will need a backtrack in archwire size to regain control appliances were superior to plain edgewise, but the former are overwhelmingly preferred for reasons that are regarded by clinicians as being self-evident and in no need of the highest order of scientific proof.

 
The ‘nickel-titanium’ dilemma: this name refers to the fact that it is almost universally accepted that nickel-titanium archwires are superior for tooth alignment when compared to their stainless steel predecessors; however, none of the studies which investigated that hypothesis ever demonstrated its truth. Similarly, no study ever demonstrated that pre-adjusted edgewise

Is self-ligation less painful?
There have been a number of studies investigating this hypothesis.15Go,16Go,22Go,23Go Tagawa15Go found a substantial reduction in reported pain with Damon SL brackets and Pringle et al.24Go found significantly less pain with Damon 3 brackets; however other authors16Go,22Go have found no difference in the first week or month of treatment and one study23Go found that archwire changes with SmartClip brackets were reported as significantly more uncomfortable. The hypothesis that self-ligation may be less painful is based on the assumption that forces on the teeth will be lower. This is not necessarily the case and force levels will be discussed later in this article.

Is self-ligation less effective at delivering torque?
This hypothesis has been advanced and is probably based on the belief that the labio-lingual forces between the base of the bracket and a ligature system are a significant additional source of force couple, adding to the couple between the upper and lower bracket walls. This situation is not straightforward and is probably influenced by several factors.

The present – further current hypotheses about self-ligation
Many clinicians who use self-ligating brackets are of the opinion that when combined with light round wires, they facilitate the alignment of crowded teeth. Some – notably Dr Dwight Damon – have also proposed that the teeth align in a qualitatively different manner, producing less incisor proclination and more lateral expansion than conventional ligation. A well known case example (Figures 10Go and 11Go) is reproduced by kind permission of Dr Damon. In this class II division 2 malocclusion, the very crowded arches have been aligned without extractions. The expectation would be that this would result in very pronounced incisor proclination. In fact the incisors moved labially less than 3 mm, but the posterior arch expansion was much greater than might have been anticipated (Figure 11Go).


Figure 10
View larger version (106K):
[in this window]
[in a new window]

 
Figure 10 A Class II division 2 case treated non-extraction using Damon 2 passive self-ligating brackets (reproduced with the kind permission of Dr Dwight Damon)

 

Figure 11
View larger version (132K):
[in this window]
[in a new window]

 
Figure 11 The changes with treatment in the lateral dimensions of the upper arch of the case in Figure 9Go (reproduced with the kind permission of Dr Dwight Damon)

 
This pattern of tooth movement has been attributed to a qualitatively different interaction of forces. In particular, it is suggested that the applied forces are so low that the lips can compete with and restrain incisor proclination. Additionally it has been proposed that the tongue position may alter in response to this expansion and possibly assist in the tooth movement. The force levels will be considered below, but first it is helpful to look at two consecutive visits in a case reproduced by kind permission of Dr David Birnie (Figure 12Go). It can be seen that the incisors have extravagantly (though temporarily) proclined. A major factor must surely be the high resistance to sliding produced by the figure of 8 elastomeric ligatures on the premolars which has prevented the excess wire sliding distally as the canines moved buccally. I suggest that self-ligation does not necessarily result in lower forces, but can generate a higher percentage of desirable force and a lower percentage of unwanted forces and it is this difference which can significantly alter the resulting tooth positions. In the case in Figure 12Go, the high and unwanted force on the incisors has arisen because of the friction from the elastomeric premolar ligatures.


Figure 12
View larger version (105K):
[in this window]
[in a new window]

 
Figure 12 The changes in one visit showing substantial incisor proclination with figure of 8 elastomeric ligatures (reproduced with the kind permission of Dr David Birnie) the displaced tooth with conventional brackets but over 80 g remains with self-ligating brackets in spite of the binding at each corner of the brackets.

 
The potential for measurement of these forces has been advanced to a very substantial degree by the work of Dr Badawi and co-workers at the University of Alberta into a force measurement system of impressive power, realism and versatility (Figure 13Go). This device can realistically simulate almost any arch alignment with any combination of brackets and archwires and measure all the forces and moments simultaneously. Data from this equipment have been presented at several international meetings and results which are in press with the American Journal of Orthodontics and Dentofacial Orthopedics27Go demonstrate the much higher unwanted forces with conventional brackets and also significantly higher unwanted forces with active self-ligation when compared with a passive system.


Figure 13
View larger version (108K):
[in this window]
[in a new window]

 
Figure 13 The Orthodontic Simulator (OSIM) developed by Hisham Badawi (reproduced with the kind permission of the author)

 
The higher percentage of desirable force which can result from self-ligation is neatly and simply shown in the excellent study by Baccetti et al.28Go The simple but clever and illuminating aspect of this laboratory use of a strain gauge is that instead of measuring the force required to draw a wire through an irregular sequence of brackets (i.e. the unwanted resistance to movement), it measures the net desired force remaining on a displaced tooth. The study showed that a tooth displaced 3 mm vertically from the line of the arch with a 0.012'' wire has only 50 g of net aligning force available with conventional ligation compared to over 90 g with most self-ligating brackets. With 4.5 mm of displacement, there is no remaining force available for alignment of

These recent studies support this author’s view that self-ligation is not inherently and in all situations a low force system. Indeed with any given wire the lack of friction raises the net force on irregular teeth; however, the highly significant corollary is that with a suitably low-force wire in an irregular arch, self-ligation can still produce effective tooth moving forces28Go and these forces are combined with low unwanted forces on adjacent teeth. It is these unwanted forces which can resist or adversely change the direction of tooth movement. This difference in the combination of desirable and unwanted forces requires further experimental confirmation, but is probably a distinctive feature of self-ligation, which is less obvious than the combination of low friction and good control, but is equally significant. The role of forces arising from the soft tissues will remain less amenable to realistic measurement, but it may not be necessary to propose any significant change in soft tissue behaviour in order to explain tooth movements which at first encounter may prompt such suggestions. The exploration of this area of conjecture has some similarities to the long journey which led to our sound

Does self-ligation reduce the need for extractions?
A scrutiny of this claim benefits from some dissection of the indications for extraction (Table 1Go).


View this table:
[in this window]
[in a new window]

 
Table 1 Reasons for extraction of teeth.
 
Crowding: the combination of low friction and good archwire control which self-ligation provides makes it practically easier to align crowded arches without extractions, if that is desired, than with conventional ligation. This reason for extraction is correspondingly reduced.

Profile: if research confirms that self-ligation can align teeth with less incisor proclination and relatively more lateral expansion, then this would reduce the need for extraction to prevent or correct a profile which is too full.

Interarch relationships: self-ligation in itself does not, in the opinion of this author, reduce the potential role for extractions to reduce an overjet. It may however help prevent the creation of an unwanted overjet as illustrated in Figure 12Go. With regard to establishing a positive overbite, it is equally possible that a reduction in incisor proclination for a given amount of tooth alignment may reduce the need for extractions to maintain a positive overbite, but there will always be cases where any such effect will be insufficient to eliminate the need for extractions. Such a case is illustrated in Figure 14Go where self-ligation probably facilitated the alignment of very crowded teeth, but where extractions were still included in order to help achieve the incisor relationship.


Figure 14
View larger version (131K):
[in this window]
[in a new window]

 
Figure 14 A case treated with passive self-ligation with extractions indicated by the need to create a positive incisor overbite rather than by the need to accommodate crowded teeth understanding and quantification of the mode of action of functional appliances.

 
This case has a very different initial incisor relationship to the case in Figure 10Go and hence the indication for extraction although the degree of crowding is similar in the two cases.

These potential biomechanical differences with self-ligation compared with conventional ligation do, of course, leave as a separate, but related issue the choice for every clinician of the treatment goals in relation to arch expansion or antero-posterior incisor position.


    Self-ligation – the future
 Top
 Introduction
 The past - historical...
 The present - the...
 Self-ligation - the future
 References
 
Lastly, this Northcroft lecture gives some hostages to fortune by including some predictions about self-ligation in the future. With regard to research, I predict that investigations with equipment such as Hisham Badawi’s OSIM will show that the biomechanics is not always straightforward, but that self-ligation does indeed offer different and more desirable forces when compared to conventional ligation and that active self-ligating brackets are rather less advantageous than passive brackets in this regard. With regard to treatment efficiency, I predict that RCTs will continue to fail to show that there is a blanket advantage for self-ligation in this respect, but that if investigators and funding persist (and they did not with nickel–titanium archwires or the pre-adjusted appliance), it will eventually be shown that in some malocclusions treated with particular brackets and wires and treatment intervals, self-ligation is more efficient.

With regard to clinical practice, I predict that self-ligation will continue its advance to becoming the conventional form of ligation. At the lowest denominator this will be driven by the speed, convenience and neatness of the ligation mechanism, which was the original motivation for developing such brackets. The other currently established advantages will add to the clinician’s appreciation of these brackets and the exploration of the wider hypotheses will be fascinating to observe and to take part in. George Northcroft was clearly keen on clinicians sharing their thoughts and experiences and he initiated and fostered collective learning. In the hundred years since he sparked what was to grow into the British Orthodontic Society, there have been many new ideas and innovations. We owe it to our patients to bring an enthusiastic, yet informed and critical scrutiny to all of these ideas and developments, but I am confident that at this stage, he would have come to the view that self-ligation is an idea whose time has come.


    References
 Top
 Introduction
 The past - historical...
 The present - the...
 Self-ligation - the future
 References
 
1 Birnie D, Harradine N. Self-ligating brackets. Seminars in Orthod 2008; 14.

2 Birnie D, Harradine N. Excellence in Orthodontics Lecture Course Manual 2009.

3 Eliades T, Pandis N. Self-ligation in Orthodontics. Hoboken, NJ: Wiley-Blackwell, 2009.

4 Damon D. Treatment of the face with biocompatible orthodontics. In Graber L, Vanarsdall R, Vig K (eds.). Orthodontics: current principles and techniques, 4th Edn. St Louis, MO: Elsevier, 2005, 753–832.

5 Shivapuja PK, Berger J. A comparative study of conventional ligation and self-ligating bracket systems Am J Orthod Dentofac Orthop 1994; 106: 472–80.[Medline]

6 Matasa CG. Brackets’ shape influences friction. The Orthodontic Materials Insider 2001; 13: 2–5.

7 Pandis N,Bourauel C, Eliades T. Changes in the stiffness of the ligating mechanism in retrieved active self-ligating brackets. Am J Orthod Dentofac Orthop 2007; 132: 834–37.[CrossRef][Medline]

8 Thorstenson BS, Kusy RP. Resistance to sliding of self-ligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states. Am J Orthod Dentofac Orthop 2001; 120: 361–70.[CrossRef][Medline]

9 Thorstenson BS, Kusy RP. Comparison of resistance to sliding between different self-ligating brackets with second-order angulation in the dry and saliva states. Am J Orthod Dentofac Orthop 2002; 121: 472–82.[CrossRef][Medline]

10 Thorstenson BS, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofac Orthop 2002; 122: 295–305.[CrossRef][Medline]

11 Thorstenson BS, Kusy RP. Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the wet and dry state. Angle Orthod 2003; 73: 418–30.[Medline]

12 Turnbull NR, Birnie DJ. Treatment efficiency of conventional versus self-ligating brackets: the effects of archwire size & material. Am J Orthod Dentofac Orthop 2007; 131: 395–99.[CrossRef][Medline]

13 Harradine N. Self-ligating brackets and treatment efficiency. Clin Orthod Resh 2001; 4: 220–27.[CrossRef]

14 Eberting J, Straja S, Tuncay OC. Treatment time, outcome and patient satisfaction comparisons of Damon and conventional brackets. Clin Orthod and Res 2001; 4: 228–34.[CrossRef]

15 Tagawa D. The Damon system vs. conventional appliances: a comparative study. Clin Impressions 2006; 15: 4–9.

16 Miles PG, Weyant RJ, Rustveld L. A clinical trial of Damon 2 vs conventional twin brackets during initial alignment. Angle Orthod 2006; 76: 480–85.[Medline]

17 Miles PG. SmartClip versus conventional twin brackets for initial alignment: is there a difference? Australian Orthod J 2005; 21: 123–27.

18 Miles PG. Self-ligating versus conventional twin brackets during en-masse space closure with sliding mechanics. Am J Orthod Dentofac Orthop 2007; 132: 223–25.[CrossRef][Medline]

19 Pandis N, Polychronopoulou A, Eliades T. Self-ligation vs. conventional brackets in the treatment of mandibular crowding: a prospective clinical trial of treatment duration and dental effects. Am J Orthod Dentofac Orthop 2007; 132: 208–15.[CrossRef][Medline]

20 Scott P, DiBiase AT, Sherriff M, Cobourne MT. Alignment efficiency of Damon 3 self-ligating and conventional orthodontic bracket systems: a randomized clinical trial. Am J Orthod Dentofac Orthop 2008; 134: 470.e1–470.e8.[CrossRef][Medline]

21 Fleming PS, DiBiase AT, Sarri G, Lee RT. Efficiency of mandibular arch alignment with 2 preadjusted edgewise appliances. Am J Orthod Dentofac Orthop 2009; 135: 597–602.[CrossRef][Medline]

22 Fleming PS, Di Biase AT, Sarri G, Lee RT. Pain experience during initial alignment with a self-ligating and a conventional fixed orthodontic appliance system. Angle Orthod 2009; 79: 46–50.[CrossRef][Medline]

23 Scott P, Sherriff M, DiBiase AT, Cobourne MT. Perception of discomfort during initial orthodontic tooth alignment using a self-ligating or conventional bracket system: a randomized clinical trial. Eur J Orthod 2009; 30: 227–32.[CrossRef]

24 Pringle AM, McKnight MM, Petrie A, Cunningam SJ. An RCT comparing pain associated with two fixed appliance systems. J Orthod 2008; abstract 54.

25 Badawi H, Toogood RW, CareyJPR, Heo G, Major PW. Torque expression of self-ligating brackets Am J Orthod Dentofac Orthop 2008; 133: 721–28.[CrossRef][Medline]

26 Pandis, Strigou S, Eliades T. Maxillary incisor torque with conventional and self-ligating brackets: a prospective clinical trial. Orthod Craniofac Res 2006; 9: 193–98.[Medline]

27 Badawi H et al. Three-dimensional orthodontic force measurements: high upper cuspid. Am J Orthod Dentofac Orthop, in press.

28 Baccetti T, Franchi L, Camporesi M, Defraia E, Barabato E. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth. Angle Orthod 2009; 79: 533–39.[Medline]





This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Harradine, N.
PubMed
Right arrow Articles by Harradine, N.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS